-
Je něco špatně v tomto záznamu ?
Acute to long-term characteristics of impedance recordings during neurostimulation in humans
J. Cui, F. Mivalt, V. Sladky, J. Kim, TJ. Richner, BN. Lundstrom, JJ. Van Gompel, HL. Wang, KJ. Miller, N. Gregg, LJ. Wu, T. Denison, B. Winter, BH. Brinkmann, V. Kremen, GA. Worrell
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
Grantová podpora
R01 NS092882
NINDS NIH HHS - United States
R01 NS112144
NINDS NIH HHS - United States
UG3 NS123066
NINDS NIH HHS - United States
UH3 NS095495
NINDS NIH HHS - United States
PubMed
38484397
DOI
10.1088/1741-2552/ad3416
Knihovny.cz E-zdroje
- MeSH
- cizí tělesa * MeSH
- elektrická impedance MeSH
- hluboká mozková stimulace * metody MeSH
- implantované elektrody MeSH
- lidé MeSH
- mozek fyziologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Objective.This study aims to characterize the time course of impedance, a crucial electrophysiological property of brain tissue, in the human thalamus (THL), amygdala-hippocampus, and posterior hippocampus over an extended period.Approach.Impedance was periodically sampled every 5-15 min over several months in five subjects with drug-resistant epilepsy using an investigational neuromodulation device. Initially, we employed descriptive piecewise and continuous mathematical models to characterize the impedance response for approximately three weeks post-electrode implantation. We then explored the temporal dynamics of impedance during periods when electrical stimulation was temporarily halted, observing a monotonic increase (rebound) in impedance before it stabilized at a higher value. Lastly, we assessed the stability of amplitude and phase over the 24 h impedance cycle throughout the multi-month recording.Main results.Immediately post-implantation, the impedance decreased, reaching a minimum value in all brain regions within approximately two days, and then increased monotonically over about 14 d to a stable value. The models accounted for the variance in short-term impedance changes. Notably, the minimum impedance of the THL in the most epileptogenic hemisphere was significantly lower than in other regions. During the gaps in electrical stimulation, the impedance rebound decreased over time and stabilized around 200 days post-implant, likely indicative of the foreign body response and fibrous tissue encapsulation around the electrodes. The amplitude and phase of the 24 h impedance oscillation remained stable throughout the multi-month recording, with circadian variation in impedance dominating the long-term measures.Significance.Our findings illustrate the complex temporal dynamics of impedance in implanted electrodes and the impact of electrical stimulation. We discuss these dynamics in the context of the known biological foreign body response of the brain to implanted electrodes. The data suggest that the temporal dynamics of impedance are dependent on the anatomical location and tissue epileptogenicity. These insights may offer additional guidance for the delivery of therapeutic stimulation at various time points post-implantation for neuromodulation therapy.
Department of Engineering Science University of Oxford
Department of Neurologic Surgery Mayo Clinic Rochester MN United States of America
Department of Neurology Mayo Clinic Rochester MN United States of America
Faculty of Biomedical Engineering Czech Technical University Prague Kladno Czech Republic
International Clinical Research Center St Anne's University Hospital Brno Czech Republic
Mayo College of Medicine and Science Mayo Clinic Rochester MN United States of America
MRC Brain Network Dynamics Unit University of Oxford Oxford OX3 7DQ United Kingdom
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24014374
- 003
- CZ-PrNML
- 005
- 20240905134258.0
- 007
- ta
- 008
- 240725s2024 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1088/1741-2552/ad3416 $2 doi
- 035 __
- $a (PubMed)38484397
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Cui, Jie $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $u Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, United States of America $u Mayo College of Medicine and Science, Mayo Clinic, Rochester, MN, United States of America $1 https://orcid.org/0000000310008869
- 245 10
- $a Acute to long-term characteristics of impedance recordings during neurostimulation in humans / $c J. Cui, F. Mivalt, V. Sladky, J. Kim, TJ. Richner, BN. Lundstrom, JJ. Van Gompel, HL. Wang, KJ. Miller, N. Gregg, LJ. Wu, T. Denison, B. Winter, BH. Brinkmann, V. Kremen, GA. Worrell
- 520 9_
- $a Objective.This study aims to characterize the time course of impedance, a crucial electrophysiological property of brain tissue, in the human thalamus (THL), amygdala-hippocampus, and posterior hippocampus over an extended period.Approach.Impedance was periodically sampled every 5-15 min over several months in five subjects with drug-resistant epilepsy using an investigational neuromodulation device. Initially, we employed descriptive piecewise and continuous mathematical models to characterize the impedance response for approximately three weeks post-electrode implantation. We then explored the temporal dynamics of impedance during periods when electrical stimulation was temporarily halted, observing a monotonic increase (rebound) in impedance before it stabilized at a higher value. Lastly, we assessed the stability of amplitude and phase over the 24 h impedance cycle throughout the multi-month recording.Main results.Immediately post-implantation, the impedance decreased, reaching a minimum value in all brain regions within approximately two days, and then increased monotonically over about 14 d to a stable value. The models accounted for the variance in short-term impedance changes. Notably, the minimum impedance of the THL in the most epileptogenic hemisphere was significantly lower than in other regions. During the gaps in electrical stimulation, the impedance rebound decreased over time and stabilized around 200 days post-implant, likely indicative of the foreign body response and fibrous tissue encapsulation around the electrodes. The amplitude and phase of the 24 h impedance oscillation remained stable throughout the multi-month recording, with circadian variation in impedance dominating the long-term measures.Significance.Our findings illustrate the complex temporal dynamics of impedance in implanted electrodes and the impact of electrical stimulation. We discuss these dynamics in the context of the known biological foreign body response of the brain to implanted electrodes. The data suggest that the temporal dynamics of impedance are dependent on the anatomical location and tissue epileptogenicity. These insights may offer additional guidance for the delivery of therapeutic stimulation at various time points post-implantation for neuromodulation therapy.
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a elektrická impedance $7 D017097
- 650 _2
- $a mozek $x fyziologie $7 D001921
- 650 _2
- $a implantované elektrody $7 D004567
- 650 12
- $a hluboká mozková stimulace $x metody $7 D046690
- 650 12
- $a cizí tělesa $7 D005547
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Mivalt, Filip $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic $u International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic $1 https://orcid.org/0000000206939495
- 700 1_
- $a Sladky, Vladimir $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $u International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic $1 https://orcid.org/0000000247127039
- 700 1_
- $a Kim, Jiwon $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America
- 700 1_
- $a Richner, Thomas J $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America
- 700 1_
- $a Lundstrom, Brian N $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $1 https://orcid.org/0000000253105549
- 700 1_
- $a Van Gompel, Jamie J $u Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, United States of America $1 https://orcid.org/0000000180877870
- 700 1_
- $a Wang, Hai-Long $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $1 https://orcid.org/0000000190133007
- 700 1_
- $a Miller, Kai J $u Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, United States of America
- 700 1_
- $a Gregg, Nicholas $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $1 https://orcid.org/000000026151043X
- 700 1_
- $a Wu, Long Jun $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $1 https://orcid.org/0000000180193380
- 700 1_
- $a Denison, Timothy $u Department of Engineering Science, University of Oxford; MRC Brain Network Dynamics Unit, University of Oxford, Oxford OX3 7DQ, United Kingdom $1 https://orcid.org/0000000254044004
- 700 1_
- $a Winter, Bailey $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $u Mayo College of Medicine and Science, Mayo Clinic, Rochester, MN, United States of America $1 https://orcid.org/0000000311572138
- 700 1_
- $a Brinkmann, Benjamin H $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $u Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, United States of America $1 https://orcid.org/0000000223928608
- 700 1_
- $a Kremen, Vaclav $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $u Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University, Prague, Czech Republic $1 https://orcid.org/0000000198447617
- 700 1_
- $a Worrell, Gregory A $u Department of Neurology, Mayo Clinic, Rochester, MN, United States of America $u Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, United States of America $1 https://orcid.org/0000000329160553
- 773 0_
- $w MED00188777 $t Journal of neural engineering $x 1741-2552 $g Roč. 21, č. 2 (2024)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38484397 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240725 $b ABA008
- 991 __
- $a 20240905134252 $b ABA008
- 999 __
- $a ok $b bmc $g 2143880 $s 1226240
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 21 $c 2 $e 20240403 $i 1741-2552 $m Journal of neural engineering $n J Neural Eng $x MED00188777
- GRA __
- $a R01 NS092882 $p NINDS NIH HHS $2 United States
- GRA __
- $a R01 NS112144 $p NINDS NIH HHS $2 United States
- GRA __
- $a UG3 NS123066 $p NINDS NIH HHS $2 United States
- GRA __
- $a UH3 NS095495 $p NINDS NIH HHS $2 United States
- LZP __
- $a Pubmed-20240725