Je něco špatně v tomto záznamu ?
Autologous fat reinjection after preservation at -2 to -18°c: a clinical study of 973 patients
Mohammad Salman Saeed, Qasim S. Al Chalabi, Husam Ali Salman
Jazyk angličtina Země Česko
Typ dokumentu klinická studie
Digitální knihovna NLK
Zdroj
NLK
ROAD: Directory of Open Access Scholarly Resources
od 2011
- MeSH
- autologní transplantace * metody přístrojové vybavení MeSH
- dospělí MeSH
- kryoprezervace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- obličej chirurgie MeSH
- statistika jako téma MeSH
- tuková tkáň * chirurgie transplantace MeSH
- zákroky plastické chirurgie metody přístrojové vybavení MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- ženské pohlaví MeSH
- Publikační typ
- klinická studie MeSH
Objective: To study the efficacy of autologous fat transplantation after preservation at -2 to -18°C in a domestic refrigerator.Patients and methods: This study was conducted in a private clinic from December 2017 to December 2021. A total of 973 female patients were included. Under a full aseptic technique, fat was harvested using a 4 mm suction blunt cannula with three longitudinal slits. Three 50 mL syringes of fat were obtained before transferring it to 10 mL syringes; then, the fat was centrifuged at 3500 rpm for 1 min and injected through an 18 gauge blunt cannula. In addition, 50 mL of fat without centrifugation was stored in a domestic refrigerator for 3 weeks to be reinjected after fast thawing for 20 min, and then centrifuged to be ready for the second session. All participants had follow-up visits at 3 weeks, 6 months, and 1 year.Results: Participants ranged in age from 18 to 65 years. The abdomen was the fat donor site in 63.3% of the patients, while round-face style augmentation was performed in 48.3% of the patients. An assessment at 3 weeks revealed that 84.1% of patients required a second session. After 6 months, on an assessment using a 10-point scale, patients who received a single session and a second session scored 6.05 and 7.46, respectively. At 1 year, the assessment scores were 5.65 and 7.12 for those with a single and second session, respectively, and 60% of patients were fully satisfied.Conclusion: Autologous fat preserved in a domestic refrigerator for 3 weeks is a safe, cheap, and tolerated filler for facial augmentation.
M D Dermatology and Venereology Al Sadir Teaching Hospital in Missan Der matology Section
M D Dermatology and Venereology University of Baghdad Department of Medicine Dermatology Section
M D Dermatology and Venereology University of Mosul Department of Medicine Dermatology Section
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24016052
- 003
- CZ-PrNML
- 005
- 20241117224941.0
- 007
- ta
- 008
- 241022s2024 xr da f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.31482/mmsl.2023.035 $2 doi
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Saeed, Mohammad Salman $u M.D. Dermatology and Venereology, Al Sadir Teaching Hospital in Missan, Der matology Section
- 245 10
- $a Autologous fat reinjection after preservation at -2 to -18°c: a clinical study of 973 patients / $c Mohammad Salman Saeed, Qasim S. Al Chalabi, Husam Ali Salman
- 520 9_
- $a Objective: To study the efficacy of autologous fat transplantation after preservation at -2 to -18°C in a domestic refrigerator.Patients and methods: This study was conducted in a private clinic from December 2017 to December 2021. A total of 973 female patients were included. Under a full aseptic technique, fat was harvested using a 4 mm suction blunt cannula with three longitudinal slits. Three 50 mL syringes of fat were obtained before transferring it to 10 mL syringes; then, the fat was centrifuged at 3500 rpm for 1 min and injected through an 18 gauge blunt cannula. In addition, 50 mL of fat without centrifugation was stored in a domestic refrigerator for 3 weeks to be reinjected after fast thawing for 20 min, and then centrifuged to be ready for the second session. All participants had follow-up visits at 3 weeks, 6 months, and 1 year.Results: Participants ranged in age from 18 to 65 years. The abdomen was the fat donor site in 63.3% of the patients, while round-face style augmentation was performed in 48.3% of the patients. An assessment at 3 weeks revealed that 84.1% of patients required a second session. After 6 months, on an assessment using a 10-point scale, patients who received a single session and a second session scored 6.05 and 7.46, respectively. At 1 year, the assessment scores were 5.65 and 7.12 for those with a single and second session, respectively, and 60% of patients were fully satisfied.Conclusion: Autologous fat preserved in a domestic refrigerator for 3 weeks is a safe, cheap, and tolerated filler for facial augmentation.
- 650 07
- $a dospělí $7 D000328 $2 czmesh
- 650 07
- $a ženské pohlaví $7 D005260 $2 czmesh
- 650 07
- $a lidé $7 D006801 $2 czmesh
- 650 07
- $a lidé středního věku $7 D008875 $2 czmesh
- 650 07
- $a mladý dospělý $7 D055815 $2 czmesh
- 650 17
- $a autologní transplantace $x metody $x přístrojové vybavení $7 D014182 $2 czmesh
- 650 07
- $a zákroky plastické chirurgie $x metody $x přístrojové vybavení $7 D019651 $2 czmesh
- 650 07
- $a obličej $x chirurgie $7 D005145 $2 czmesh
- 650 17
- $a tuková tkáň $x chirurgie $x transplantace $7 D000273 $2 czmesh
- 650 07
- $a kryoprezervace $x metody $7 D015925 $2 czmesh
- 650 07
- $a statistika jako téma $7 D013223 $2 czmesh
- 655 _7
- $a klinická studie $7 D000068397 $2 czmesh
- 700 1_
- $a Al Chalabi, Qasim S. $u M.D. Dermatology and Venereology, University of Mosul, Department of Medicine, Dermatology Section
- 700 1_
- $a Salman, Husam Ali $u M.D. Dermatology and Venereology, University of Baghdad, Department of Medicine, Dermatology Section
- 773 0_
- $t Vojenské zdravotnické listy $x 0372-7025 $g Roč. 93, č. 3 (2024), s. 288-296 $w MED00011116
- 856 41
- $u https://mmsl.cz/artkey/mms-202403-0006_autologous-fat-reinjection-after-preservation-at-8722-2-to-8722-18-c-a-clinical-study-of-973-patients.php $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 3 $c 1073 $y p $z 0
- 990 __
- $a 20240903 $b ABA008
- 991 __
- $a 20241117224941 $b ABA008
- 999 __
- $a ok $b bmc $g 2203868 $s 1227970
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2024 $b 93 $c 3 $d 288-296 $e 20240902 $i 0372-7025 $m Vojenské zdravotnické listy $x MED00011116
- LZP __
- $c NLK189 $d 20241117 $b NLK111 $a Actavia-MED00011116-20240903