• Something wrong with this record ?

Measuring critical force in sport climbers: a validation study of the 4 min all-out test on finger flexors

B. Jiří, G. Jan, J. Tomáš, B. Patrik, F. Andri

. 2024 ; 124 (9) : 2787-2798. [pub] 20240426

Language English Country Germany

Document type Journal Article, Validation Study

Grant support
Cooperatio - Sport Sciences - Biomedical and Rehabilitation Medicine Univerzita Karlova v Praze

E-resources Online Full text

NLK ProQuest Central from 2000-01-01 to 1 year ago
Medline Complete (EBSCOhost) from 2000-01-01 to 1 year ago
Nursing & Allied Health Database (ProQuest) from 2000-01-01 to 1 year ago
Health & Medicine (ProQuest) from 2000-01-01 to 1 year ago

PURPOSE: The critical force (CF) concept, differentiating steady and non-steady state conditions, extends the critical power paradigm for sport climbing. This study aimed to validate CF for finger flexors derived from the 4 min all-out test as a boundary for the highest sustainable work intensity in sport climbers. METHODS: Twelve participants underwent multiple laboratory visits. Initially, they performed the 4 min intermittent contraction all-out test for CF determination. Subsequent verification visits involved finger-flexor contractions at various intensities, including CF, CF -2 kg, CF -4 kg, and CF -6 kg, lasting for 720 s or until failure, while monitoring muscle-oxygen dynamics of forearm muscles. RESULTS: CF, determined from the mean force of last three contractions, was measured at 20.1 ± 5.7 kg, while the end-force at 16.8 ± 5.2 kg. In the verification trials, the mean time to failure at CF was 440 ± 140 s, with only one participant completing the 720 s task. When the load was continuously lowered (-2 kg, -4 kg, and -6 kg), a greater number of participants (38%, 69%, and 92%, respectively) successfully completed the 720 s task. Changes of muscle-oxygen dynamics showed a high variability and could not clearly distinguish between exhaustive and non-exhaustive trials. CONCLUSIONS: CF, based on the mean force of the last three contractions, failed to reliably predict the highest sustainable work rate. In contrast, determining CF as the end-force of the last three contractions exhibited a stronger link to sustainable work. Caution is advised in interpreting forearm muscle-oxygen dynamics, lacking sensitivity for nuanced metabolic responses during climbing-related tasks.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24019189
003      
CZ-PrNML
005      
20241024111658.0
007      
ta
008      
241015s2024 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00421-024-05490-7 $2 doi
035    __
$a (PubMed)38668851
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Jiří, Baláš $u Faculty of Physical Education and Sport, Charles University, José Martího 31, 16252, Prague 6, Czech Republic. jiri.balas@ftvs.cuni.cz $1 https://orcid.org/0000000335022050 $7 mzk2008443046
245    10
$a Measuring critical force in sport climbers: a validation study of the 4 min all-out test on finger flexors / $c B. Jiří, G. Jan, J. Tomáš, B. Patrik, F. Andri
520    9_
$a PURPOSE: The critical force (CF) concept, differentiating steady and non-steady state conditions, extends the critical power paradigm for sport climbing. This study aimed to validate CF for finger flexors derived from the 4 min all-out test as a boundary for the highest sustainable work intensity in sport climbers. METHODS: Twelve participants underwent multiple laboratory visits. Initially, they performed the 4 min intermittent contraction all-out test for CF determination. Subsequent verification visits involved finger-flexor contractions at various intensities, including CF, CF -2 kg, CF -4 kg, and CF -6 kg, lasting for 720 s or until failure, while monitoring muscle-oxygen dynamics of forearm muscles. RESULTS: CF, determined from the mean force of last three contractions, was measured at 20.1 ± 5.7 kg, while the end-force at 16.8 ± 5.2 kg. In the verification trials, the mean time to failure at CF was 440 ± 140 s, with only one participant completing the 720 s task. When the load was continuously lowered (-2 kg, -4 kg, and -6 kg), a greater number of participants (38%, 69%, and 92%, respectively) successfully completed the 720 s task. Changes of muscle-oxygen dynamics showed a high variability and could not clearly distinguish between exhaustive and non-exhaustive trials. CONCLUSIONS: CF, based on the mean force of the last three contractions, failed to reliably predict the highest sustainable work rate. In contrast, determining CF as the end-force of the last three contractions exhibited a stronger link to sustainable work. Caution is advised in interpreting forearm muscle-oxygen dynamics, lacking sensitivity for nuanced metabolic responses during climbing-related tasks.
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    12
$a kosterní svaly $x fyziologie $7 D018482
650    12
$a prsty ruky $x fyziologie $7 D005385
650    _2
$a dospělí $7 D000328
650    12
$a horolezectví $x fyziologie $7 D009051
650    _2
$a svalová kontrakce $x fyziologie $7 D009119
650    _2
$a spotřeba kyslíku $x fyziologie $7 D010101
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
655    _2
$a validační studie $7 D023361
700    1_
$a Jan, Gajdošík $u Faculty of Physical Education and Sport, Charles University, José Martího 31, 16252, Prague 6, Czech Republic $1 https://orcid.org/0000000316163042 $7 xx0241113
700    1_
$a Tomáš, Javorský $u Faculty of Physical Education and Sport, Charles University, José Martího 31, 16252, Prague 6, Czech Republic $u Department of Sport Science, University of Innsbruck, Innsbruck, Austria $1 https://orcid.org/0009000424242896
700    1_
$a Patrik, Berta $u Faculty of Physical Education and Sport, Charles University, José Martího 31, 16252, Prague 6, Czech Republic $1 https://orcid.org/0000000260218576
700    1_
$a Andri, Feldmann $u Institute of Sport Science, University of Bern, Bern, Switzerland $1 https://orcid.org/0000000201711125
773    0_
$w MED00005445 $t European journal of applied physiology $x 1439-6327 $g Roč. 124, č. 9 (2024), s. 2787-2798
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38668851 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20241015 $b ABA008
991    __
$a 20241024111652 $b ABA008
999    __
$a ok $b bmc $g 2201807 $s 1231162
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 124 $c 9 $d 2787-2798 $e 20240426 $i 1439-6327 $m European journal of applied physiology $n Eur J Appl Physiol $x MED00005445
GRA    __
$a Cooperatio - Sport Sciences - Biomedical and Rehabilitation Medicine $p Univerzita Karlova v Praze
LZP    __
$a Pubmed-20241015

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...