Je něco špatně v tomto záznamu ?
Comparison of dose length product and image quality of a biphasic whole-body polytrauma CT protocol with and without the automatic tube voltage selection
D. Girsa, K. Kremenova, J. Lukavsky, L. Sukupova, H. Malikova
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články, pozorovací studie, srovnávací studie
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 1998
Medline Complete (EBSCOhost)
od 2007-06-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
38445394
DOI
10.5507/bp.2024.004
Knihovny.cz E-zdroje
- MeSH
- celotělové zobrazování * metody MeSH
- dávka záření * MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- počítačová rentgenová tomografie * metody MeSH
- polytrauma * diagnostické zobrazování MeSH
- prospektivní studie MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- srovnávací studie MeSH
BACKGROUND AND AIMS: A significant source of man-made radiation is now linked to medical devices especially X-ray imaging based ones like CT scans which expose the body to cumulative ionizing radiation and thus attendant cancer risks. The aim of this study was to determine whether using a combination of Automatic Tube Current Modulation (ATCM) and Automatic Tube Voltage Selection (ATVS) during two-phase whole-body CT (2PWBCT) examinations would reduce the radiation dose while preserving the image quality. PATIENTS AND METHODS: This was a prospective, observational, single-centre study of 127 adult patients who had undergone the 2PWBCT polytraumatic protocol. All were examined on a Somatom Drive scanner (Siemens). The patients were divided into two groups: ATCM only (42 patients) and ATCM +ATVS (85 patients). Patients' arm positions during examination and the examination dose length product (DLP) values were recorded, as well the standard deviations (SD) of the density in reference areas on CT scans for the image quality assessment. The DLP values and image quality in the groups were compared using ANOVA. RESULTS: Mean Total DLP (in mGy*cm): ATCM only: 3337 +/-797, ATCM+ATVS: 3402 +/-830; P=0.674. No effect of arm position (P=0.586). Mean density SD values in reference areas (in HU) in ATCM only: 49 +/-45, 15 +/-6, 9 +/-2, 12 +/-4, 10 +/-3, in ATCM+ATVS: 48 +/-45, 17 +/-6, 11 +/-3, 15 +/-6, 12 +/-4. SD values was higher in ATCM+ATVS group (P<0.001). CONCLUSION: Combination of ATVS and ATCM in polytraumatic 2PWBCT leads to no significant radiation load reduction compared with ATCM only but does lead to a slight degradation of image quality. The radiation load is significantly reduced if the patient has their arms behind the head when scanning, regardless of the activation of ATVS.
2nd Faculty of Medicine Charles University Prague Prague Czech Republic
Department of Psychology Faculty of Arts Charles University Prague Prague Czech Republic
Director's Department Institute for Clinical and Experimental Medicine Prague Czech Republic
Institute of Psychology Czech Academy of Sciences 110 00 Prague Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24022786
- 003
- CZ-PrNML
- 005
- 20250527094408.0
- 007
- ta
- 008
- 241205s2024 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2024.004 $2 doi
- 035 __
- $a (PubMed)38445394
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Girsa, David $u Department of Radiology and Nuclear Medicine, Third Faculty of Medicine, Charles University in Prague and Faculty Hospital Kralovske Vinohrady; Second Faculty of Medicine, Charles University in Prague, Prague, Czech Republic $7 xx0243240
- 245 10
- $a Comparison of dose length product and image quality of a biphasic whole-body polytrauma CT protocol with and without the automatic tube voltage selection / $c D. Girsa, K. Kremenova, J. Lukavsky, L. Sukupova, H. Malikova
- 520 9_
- $a BACKGROUND AND AIMS: A significant source of man-made radiation is now linked to medical devices especially X-ray imaging based ones like CT scans which expose the body to cumulative ionizing radiation and thus attendant cancer risks. The aim of this study was to determine whether using a combination of Automatic Tube Current Modulation (ATCM) and Automatic Tube Voltage Selection (ATVS) during two-phase whole-body CT (2PWBCT) examinations would reduce the radiation dose while preserving the image quality. PATIENTS AND METHODS: This was a prospective, observational, single-centre study of 127 adult patients who had undergone the 2PWBCT polytraumatic protocol. All were examined on a Somatom Drive scanner (Siemens). The patients were divided into two groups: ATCM only (42 patients) and ATCM +ATVS (85 patients). Patients' arm positions during examination and the examination dose length product (DLP) values were recorded, as well the standard deviations (SD) of the density in reference areas on CT scans for the image quality assessment. The DLP values and image quality in the groups were compared using ANOVA. RESULTS: Mean Total DLP (in mGy*cm): ATCM only: 3337 +/-797, ATCM+ATVS: 3402 +/-830; P=0.674. No effect of arm position (P=0.586). Mean density SD values in reference areas (in HU) in ATCM only: 49 +/-45, 15 +/-6, 9 +/-2, 12 +/-4, 10 +/-3, in ATCM+ATVS: 48 +/-45, 17 +/-6, 11 +/-3, 15 +/-6, 12 +/-4. SD values was higher in ATCM+ATVS group (P<0.001). CONCLUSION: Combination of ATVS and ATCM in polytraumatic 2PWBCT leads to no significant radiation load reduction compared with ATCM only but does lead to a slight degradation of image quality. The radiation load is significantly reduced if the patient has their arms behind the head when scanning, regardless of the activation of ATVS.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a dávka záření $7 D011829
- 650 _2
- $a prospektivní studie $7 D011446
- 650 12
- $a počítačová rentgenová tomografie $x metody $7 D014057
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé středního věku $7 D008875
- 650 12
- $a polytrauma $x diagnostické zobrazování $7 D009104
- 650 12
- $a celotělové zobrazování $x metody $7 D051598
- 650 _2
- $a senioři $7 D000368
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a pozorovací studie $7 D064888
- 655 _2
- $a srovnávací studie $7 D003160
- 700 1_
- $a Kremeňová, Karin $u Department of Radiology and Nuclear Medicine, Third Faculty of Medicine, Charles University in Prague and Faculty Hospital Kralovske Vinohrady, Prague, Czech Republic $7 xx0332041
- 700 1_
- $a Lukavský, Jiří, $d 1978- $u Institute of Psychology, Czech Academy of Sciences, 110 00 Prague, Czech Republic; Department of Psychology, Faculty of Arts, Charles University in Prague, Prague, Czech Republic $7 js20060505008
- 700 1_
- $a Súkupová, Lucie $u Director's Department, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $7 xx0144800
- 700 1_
- $a Malíková, Hana $u Department of Radiology and Nuclear Medicine, Third Faculty of Medicine, Charles University in Prague and Faculty Hospital Kralovske Vinohrady; Second Faculty of Medicine, Charles University in Prague, Prague, Czech Republic $7 xx0158266
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia $x 1804-7521 $g Roč. 168, č. 4 (2024), s. 304-310
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38445394 $y Pubmed
- 910 __
- $a ABA008 $b A 1502 $c 958 $y p $z 0
- 990 __
- $a 20241205 $b ABA008
- 991 __
- $a 20250527094408 $b ABA008
- 999 __
- $a ok $b bmc $g 2324811 $s 1234791
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 168 $c 4 $d 304-310 $e 20240304 $i 1804-7521 $m Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia $n Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub $x MED00012606
- LZP __
- $b NLK124 $a Pubmed-20241205