Assessing the Test-Retest Reliability of MyotonPRO for Measuring Achilles Tendon Stiffness

K. Volesky, J. Novak, M. Janek, J. Katolicky, JJ. Tufano, M. Steffl, J. Courel-Ibáñez, T. Vetrovsky

. 2025 ; 10 (1) : . [pub] 20250228

Status not-indexed Language English Country Switzerland

Document type Journal Article

Grant support
94622 Grant Agency of Charles University

Objectives: This study evaluates the test-retest reliability and inter-rater reliability of the MyotonPRO for measuring Achilles tendon stiffness at two standardized sites over various time frames and settings. Methods: Eight healthy participants underwent assessments by three raters over six visits. Tendon stiffness was measured at proximal (mid-portion) and distal (insertional) regions of the Achilles tendon at various time frames (10-15 s, 10-15 min, 24 h, and 14 days apart). Measurements included participant repositioning and two activity stimuli (daily living and sport). Reliability was calculated using the intraclass correlation coefficient (ICC), its 95% confidence interval, coefficient of variation, standard error of measurement, and minimal detectable change. Results: Short-term reliability (10-15 min) was excellent, with an ICC of 0.956 (0.929-0.974). Between days reliability (24 h) was good, with an ICC of 0.889 (0.802-0.938). Between weeks reliability (2 weeks) was good with an ICC of 0.886 (0.811-0.931). Short-term reliability with the simulation of activity of daily living was good, with an ICC of 0.917 (0.875-0.945). Short-term reliability with the simulation of sport was good with an ICC of 0.933 (0.891-0.96). Between days reliability with the simulation of sport was good, with an ICC of 0.920 (0.859-0.955). Conclusions: When used in a standardized position, the MyotonPRO demonstrates reliable repeated measurements of Achilles tendon stiffness. This protocol provides a foundation for clinical research and rehabilitation by clarifying expected reliability across minutes, days, and weeks, thus aiding clinicians and researchers in monitoring tendon adaptations and making evidence-based decisions.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25008327
003      
CZ-PrNML
005      
20250422095807.0
007      
ta
008      
250408s2025 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/jfmk10010083 $2 doi
035    __
$a (PubMed)40137335
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Volesky, Krystof $u Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic $1 https://orcid.org/0000000305425430
245    10
$a Assessing the Test-Retest Reliability of MyotonPRO for Measuring Achilles Tendon Stiffness / $c K. Volesky, J. Novak, M. Janek, J. Katolicky, JJ. Tufano, M. Steffl, J. Courel-Ibáñez, T. Vetrovsky
520    9_
$a Objectives: This study evaluates the test-retest reliability and inter-rater reliability of the MyotonPRO for measuring Achilles tendon stiffness at two standardized sites over various time frames and settings. Methods: Eight healthy participants underwent assessments by three raters over six visits. Tendon stiffness was measured at proximal (mid-portion) and distal (insertional) regions of the Achilles tendon at various time frames (10-15 s, 10-15 min, 24 h, and 14 days apart). Measurements included participant repositioning and two activity stimuli (daily living and sport). Reliability was calculated using the intraclass correlation coefficient (ICC), its 95% confidence interval, coefficient of variation, standard error of measurement, and minimal detectable change. Results: Short-term reliability (10-15 min) was excellent, with an ICC of 0.956 (0.929-0.974). Between days reliability (24 h) was good, with an ICC of 0.889 (0.802-0.938). Between weeks reliability (2 weeks) was good with an ICC of 0.886 (0.811-0.931). Short-term reliability with the simulation of activity of daily living was good, with an ICC of 0.917 (0.875-0.945). Short-term reliability with the simulation of sport was good with an ICC of 0.933 (0.891-0.96). Between days reliability with the simulation of sport was good, with an ICC of 0.920 (0.859-0.955). Conclusions: When used in a standardized position, the MyotonPRO demonstrates reliable repeated measurements of Achilles tendon stiffness. This protocol provides a foundation for clinical research and rehabilitation by clarifying expected reliability across minutes, days, and weeks, thus aiding clinicians and researchers in monitoring tendon adaptations and making evidence-based decisions.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Novak, Jan $u Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic
700    1_
$a Janek, Michael $u Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic
700    1_
$a Katolicky, Jakub $u Department of Rehabilitation and Sports Medicine, Second Faculty of Medicine, University Hospital in Motol, Charles University, 150 06 Prague, Czech Republic $1 https://orcid.org/0000000185291975
700    1_
$a Tufano, James J $u Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic
700    1_
$a Steffl, Michal $u Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic $1 https://orcid.org/0000000172978145
700    1_
$a Courel-Ibáñez, Javier $u Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, 520 71 Melilla, Spain $1 https://orcid.org/0000000324461875
700    1_
$a Vetrovsky, Tomas $u Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic $1 https://orcid.org/0000000325297069 $7 xx0205902
773    0_
$w MED00209369 $t Journal of functional morphology and kinesiology $x 2411-5142 $g Roč. 10, č. 1 (2025)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/40137335 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20250408 $b ABA008
991    __
$a 20250422095808 $b ABA008
999    __
$a ok $b bmc $g 2306341 $s 1245402
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2025 $b 10 $c 1 $e 20250228 $i 2411-5142 $m Journal of functional morphology and kinesiology $n J Funct Morphol Kinesiol $x MED00209369
GRA    __
$a 94622 $p Grant Agency of Charles University
LZP    __
$a Pubmed-20250408

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...