-
Je něco špatně v tomto záznamu ?
Non-invasive PPG-based estimation of blood glucose level
Enikö Vargová, Andrea Němcová, Zuzana Nováková
Status minimální Jazyk angličtina Země Česko
This paper focuses on non-invasive blood glucose determination using photoplethysmographic (PPG) signals, which is crucial for managing diabetes. Diabetes stands as one of the world’s major chronic diseases. Untreated diabetes frequently leads to fatalities. Current self-monitoring techniques for measuring diabetes require invasive procedures such as blood or bodily fluid sampling, which may be very uncomfortable. Hence, there is an opportunity for non-invasive blood glucose monitoring through smart devices capable of measuring PPG signals. The primary goal of this research was to propose methods for glycemic classification into two groups (low and high glycemia) and to predict specific glycemia values using machine learning techniques. Two datasets were created by measuring PPG signals from 16 individuals using two different smart devices – a smart wristband and a smartphone. Simultaneously, the reference blood glucose levels were invasively measured using a glucometer. The PPG signals were preprocessed, and 27 different features were extracted. With the use of feature selection, only 10 relevant features were chosen. Numerous machine learning models were developed. Random Forest (RF) and Support Vector Machine (SVM) with the radial basis function (RBF) kernel performed best in classifying PPG signals into two groups. These models achieved an accuracy of 76% (SVM) and 75% (RF) on the smart wristband test dataset. The functionality of the proposed models was then verified on the smartphone test dataset, where both models achieved similar accuracy: 74% (SVM) and 75% (RF). For predicting specific glycemia values, RF performed best. Mean Absolute Error (MAE) was 1.25 mmol/l on the smart wristband test dataset and 1.37 mmol/l on the smartphone test dataset.
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc25010864
- 003
- CZ-PrNML
- 005
- 20250507092452.0
- 007
- ta
- 008
- 250422s2023 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14311/CTJ.2023.1.04 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Vargová, Enikö $7 xx0331812 $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
- 245 10
- $a Non-invasive PPG-based estimation of blood glucose level / $c Enikö Vargová, Andrea Němcová, Zuzana Nováková
- 504 __
- $a Literatura
- 520 9_
- $a This paper focuses on non-invasive blood glucose determination using photoplethysmographic (PPG) signals, which is crucial for managing diabetes. Diabetes stands as one of the world’s major chronic diseases. Untreated diabetes frequently leads to fatalities. Current self-monitoring techniques for measuring diabetes require invasive procedures such as blood or bodily fluid sampling, which may be very uncomfortable. Hence, there is an opportunity for non-invasive blood glucose monitoring through smart devices capable of measuring PPG signals. The primary goal of this research was to propose methods for glycemic classification into two groups (low and high glycemia) and to predict specific glycemia values using machine learning techniques. Two datasets were created by measuring PPG signals from 16 individuals using two different smart devices – a smart wristband and a smartphone. Simultaneously, the reference blood glucose levels were invasively measured using a glucometer. The PPG signals were preprocessed, and 27 different features were extracted. With the use of feature selection, only 10 relevant features were chosen. Numerous machine learning models were developed. Random Forest (RF) and Support Vector Machine (SVM) with the radial basis function (RBF) kernel performed best in classifying PPG signals into two groups. These models achieved an accuracy of 76% (SVM) and 75% (RF) on the smart wristband test dataset. The functionality of the proposed models was then verified on the smartphone test dataset, where both models achieved similar accuracy: 74% (SVM) and 75% (RF). For predicting specific glycemia values, RF performed best. Mean Absolute Error (MAE) was 1.25 mmol/l on the smart wristband test dataset and 1.37 mmol/l on the smartphone test dataset.
- 700 1_
- $a Němcová, Andrea $7 xx0331813 $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
- 700 1_
- $a Nováková, Zuzana, $d 1961- $7 mzk2002103492 $u Department of Physiology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- 773 0_
- $t Lékař a technika $x 0301-5491 $g Roč. 53, č. 1 (2023), s. 19-24 $w MED00011033
- 856 41
- $u https://ojs.cvut.cz/ojs/index.php/CTJ/issue/archive $y stránka časopisu
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y 0 $z 0
- 990 __
- $a 20250418131110 $b ABA008
- 991 __
- $a 20250507092450 $b ABA008
- 999 __
- $a min $b bmc $g 2306515 $s 1247945
- BAS __
- $a 3
- BMC __
- $a 2023 $b 53 $c 1 $d 19-24 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
- LZP __
- $a NLK 2025-15/dk