Non-invasive PPG-based estimation of blood glucose level

Enikö Vargová, Andrea Němcová, Zuzana Nováková

. 2023 ; 53 (1) : 19-24.

Status minimální Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc25010864

This paper focuses on non-invasive blood glucose determination using photoplethysmographic (PPG) signals, which is crucial for managing diabetes. Diabetes stands as one of the world’s major chronic diseases. Untreated diabetes frequently leads to fatalities. Current self-monitoring techniques for measuring diabetes require invasive procedures such as blood or bodily fluid sampling, which may be very uncomfortable. Hence, there is an opportunity for non-invasive blood glucose monitoring through smart devices capable of measuring PPG signals. The primary goal of this research was to propose methods for glycemic classification into two groups (low and high glycemia) and to predict specific glycemia values using machine learning techniques. Two datasets were created by measuring PPG signals from 16 individuals using two different smart devices – a smart wristband and a smartphone. Simultaneously, the reference blood glucose levels were invasively measured using a glucometer. The PPG signals were preprocessed, and 27 different features were extracted. With the use of feature selection, only 10 relevant features were chosen. Numerous machine learning models were developed. Random Forest (RF) and Support Vector Machine (SVM) with the radial basis function (RBF) kernel performed best in classifying PPG signals into two groups. These models achieved an accuracy of 76% (SVM) and 75% (RF) on the smart wristband test dataset. The functionality of the proposed models was then verified on the smartphone test dataset, where both models achieved similar accuracy: 74% (SVM) and 75% (RF). For predicting specific glycemia values, RF performed best. Mean Absolute Error (MAE) was 1.25 mmol/l on the smart wristband test dataset and 1.37 mmol/l on the smartphone test dataset.

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc25010864
003      
CZ-PrNML
005      
20250507092452.0
007      
ta
008      
250422s2023 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14311/CTJ.2023.1.04 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Vargová, Enikö $7 xx0331812 $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
245    10
$a Non-invasive PPG-based estimation of blood glucose level / $c Enikö Vargová, Andrea Němcová, Zuzana Nováková
504    __
$a Literatura
520    9_
$a This paper focuses on non-invasive blood glucose determination using photoplethysmographic (PPG) signals, which is crucial for managing diabetes. Diabetes stands as one of the world’s major chronic diseases. Untreated diabetes frequently leads to fatalities. Current self-monitoring techniques for measuring diabetes require invasive procedures such as blood or bodily fluid sampling, which may be very uncomfortable. Hence, there is an opportunity for non-invasive blood glucose monitoring through smart devices capable of measuring PPG signals. The primary goal of this research was to propose methods for glycemic classification into two groups (low and high glycemia) and to predict specific glycemia values using machine learning techniques. Two datasets were created by measuring PPG signals from 16 individuals using two different smart devices – a smart wristband and a smartphone. Simultaneously, the reference blood glucose levels were invasively measured using a glucometer. The PPG signals were preprocessed, and 27 different features were extracted. With the use of feature selection, only 10 relevant features were chosen. Numerous machine learning models were developed. Random Forest (RF) and Support Vector Machine (SVM) with the radial basis function (RBF) kernel performed best in classifying PPG signals into two groups. These models achieved an accuracy of 76% (SVM) and 75% (RF) on the smart wristband test dataset. The functionality of the proposed models was then verified on the smartphone test dataset, where both models achieved similar accuracy: 74% (SVM) and 75% (RF). For predicting specific glycemia values, RF performed best. Mean Absolute Error (MAE) was 1.25 mmol/l on the smart wristband test dataset and 1.37 mmol/l on the smartphone test dataset.
700    1_
$a Němcová, Andrea $7 xx0331813 $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
700    1_
$a Nováková, Zuzana, $d 1961- $7 mzk2002103492 $u Department of Physiology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
773    0_
$t Lékař a technika $x 0301-5491 $g Roč. 53, č. 1 (2023), s. 19-24 $w MED00011033
856    41
$u https://ojs.cvut.cz/ojs/index.php/CTJ/issue/archive $y stránka časopisu
910    __
$a ABA008 $b B 1367 $c 1071 b $y 0 $z 0
990    __
$a 20250418131110 $b ABA008
991    __
$a 20250507092450 $b ABA008
999    __
$a min $b bmc $g 2306515 $s 1247945
BAS    __
$a 3
BMC    __
$a 2023 $b 53 $c 1 $d 19-24 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
LZP    __
$a NLK 2025-15/dk

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...