Robust control of oxygen saturation during mechanical ventilation

Arnhold Lohse, Philip vonPlaten, Steffen Leonhardt, Marian Walter

. 2024 ; 54 (1) : 5-11.

Status minimální Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc25010903

Acute respiratory distress syndrome (ARDS) is a disease that has a high reported mortality rate. The treatment for ARDS typically involves mechanical ventilation that is tailored to each patient's needs. A crucial aspect of this treatment is maintaining adequate oxygen saturation of haemoglobin by setting the fraction of inspired oxygen. This paper proposes a design method of robust proportional-integral-derivative (PID) controllers using a gas exchange model during ARDS. Several PID controllers were synthesized for different sub-operational ranges defined by measurable quantities of the mechanical ventilator and the patient using a mixed sensitivity H∞ approach. In simulations, the controller demonstrated high robustness to external changes and changes in the patient's condition, with saturation always above 88%. Although further validation of the controller is required, the results indicate that the presented robust control method has the potential to be clinically relevant.

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc25010903
003      
CZ-PrNML
005      
20250423095112.0
007      
ta
008      
250422s2024 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14311/CTJ.2024.1.01 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Lohse, Arnhold $u RWTH Aachen University, Aachen, Germany
245    10
$a Robust control of oxygen saturation during mechanical ventilation / $c Arnhold Lohse, Philip vonPlaten, Steffen Leonhardt, Marian Walter
504    __
$a Literatura
520    9_
$a Acute respiratory distress syndrome (ARDS) is a disease that has a high reported mortality rate. The treatment for ARDS typically involves mechanical ventilation that is tailored to each patient's needs. A crucial aspect of this treatment is maintaining adequate oxygen saturation of haemoglobin by setting the fraction of inspired oxygen. This paper proposes a design method of robust proportional-integral-derivative (PID) controllers using a gas exchange model during ARDS. Several PID controllers were synthesized for different sub-operational ranges defined by measurable quantities of the mechanical ventilator and the patient using a mixed sensitivity H∞ approach. In simulations, the controller demonstrated high robustness to external changes and changes in the patient's condition, with saturation always above 88%. Although further validation of the controller is required, the results indicate that the presented robust control method has the potential to be clinically relevant.
700    1_
$a von Platen, Philip $u RWTH Aachen University, Aachen, Germany
700    1_
$a Leonhardt, Steffen $u RWTH Aachen University, Aachen, Germany
700    1_
$a Walter, Marian $u RWTH Aachen University, Aachen, Germany
773    0_
$t Lékař a technika $x 0301-5491 $g Roč. 54, č. 1 (2024), s. 5-11 $w MED00011033
856    41
$u https://ojs.cvut.cz/ojs/index.php/CTJ/issue/archive $y stránka časopisu
910    __
$a ABA008 $b B 1367 $c 1071 b $y 0 $z 0
990    __
$a 20250418131110 $b ABA008
991    __
$a 20250423101238 $b ABA008
999    __
$a min $b bmc $g 2306554 $s 1247984
BAS    __
$a 3
BMC    __
$a 2024 $b 54 $c 1 $d 5-11 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
LZP    __
$a NLK 2025-15/dk

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...