Robust control of oxygen saturation during mechanical ventilation
Arnhold Lohse, Philip vonPlaten, Steffen Leonhardt, Marian Walter
Status minimální Jazyk angličtina Země Česko
Acute respiratory distress syndrome (ARDS) is a disease that has a high reported mortality rate. The treatment for ARDS typically involves mechanical ventilation that is tailored to each patient's needs. A crucial aspect of this treatment is maintaining adequate oxygen saturation of haemoglobin by setting the fraction of inspired oxygen. This paper proposes a design method of robust proportional-integral-derivative (PID) controllers using a gas exchange model during ARDS. Several PID controllers were synthesized for different sub-operational ranges defined by measurable quantities of the mechanical ventilator and the patient using a mixed sensitivity H∞ approach. In simulations, the controller demonstrated high robustness to external changes and changes in the patient's condition, with saturation always above 88%. Although further validation of the controller is required, the results indicate that the presented robust control method has the potential to be clinically relevant.
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc25010903
- 003
- CZ-PrNML
- 005
- 20250423095112.0
- 007
- ta
- 008
- 250422s2024 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14311/CTJ.2024.1.01 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Lohse, Arnhold $u RWTH Aachen University, Aachen, Germany
- 245 10
- $a Robust control of oxygen saturation during mechanical ventilation / $c Arnhold Lohse, Philip vonPlaten, Steffen Leonhardt, Marian Walter
- 504 __
- $a Literatura
- 520 9_
- $a Acute respiratory distress syndrome (ARDS) is a disease that has a high reported mortality rate. The treatment for ARDS typically involves mechanical ventilation that is tailored to each patient's needs. A crucial aspect of this treatment is maintaining adequate oxygen saturation of haemoglobin by setting the fraction of inspired oxygen. This paper proposes a design method of robust proportional-integral-derivative (PID) controllers using a gas exchange model during ARDS. Several PID controllers were synthesized for different sub-operational ranges defined by measurable quantities of the mechanical ventilator and the patient using a mixed sensitivity H∞ approach. In simulations, the controller demonstrated high robustness to external changes and changes in the patient's condition, with saturation always above 88%. Although further validation of the controller is required, the results indicate that the presented robust control method has the potential to be clinically relevant.
- 700 1_
- $a von Platen, Philip $u RWTH Aachen University, Aachen, Germany
- 700 1_
- $a Leonhardt, Steffen $u RWTH Aachen University, Aachen, Germany
- 700 1_
- $a Walter, Marian $u RWTH Aachen University, Aachen, Germany
- 773 0_
- $t Lékař a technika $x 0301-5491 $g Roč. 54, č. 1 (2024), s. 5-11 $w MED00011033
- 856 41
- $u https://ojs.cvut.cz/ojs/index.php/CTJ/issue/archive $y stránka časopisu
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y 0 $z 0
- 990 __
- $a 20250418131110 $b ABA008
- 991 __
- $a 20250423101238 $b ABA008
- 999 __
- $a min $b bmc $g 2306554 $s 1247984
- BAS __
- $a 3
- BMC __
- $a 2024 $b 54 $c 1 $d 5-11 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
- LZP __
- $a NLK 2025-15/dk