Catheters and Tools with Pulsed Field Ablation-Pulmonary Vein Isolation and Nanosecond Pulse Field Ablation

J. Petru, M. Funasako, P. Neuzil

. 2025 ; 17 (2) : 273-285. [pub] 20250317

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc25015422

Pulse field ablation (PFA) has gained attention in the field of atrial fibrillation catheter treatment recently. All currently used or developed technologies use ultrashort pulses (on the order of microseconds). The Emerging CellFX System (Pulse Biosciences, Inc, Inc) utilizes nanosecond PFA (nsPFA) and is thus several orders of magnitude shorter than the initial PFA systems. There are several potential advantages of nsPFA over microsecond PFA such as deeper penetration of the electric field into tissue, creating larger and deeper ablation zones while depositing less overall energy and heat, faster treatment, and less muscle stimulation or nerve capture.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25015422
003      
CZ-PrNML
005      
20250731090951.0
007      
ta
008      
250708s2025 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ccep.2025.02.015 $2 doi
035    __
$a (PubMed)40412876
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Petru, Jan $u Department of Cardiology, Charles University, Na Homolce Hospital, Roentgenova 2, 150 30, Prague 5, Prague, Czech Republic. Electronic address: jan.petru@homolka.cz
245    10
$a Catheters and Tools with Pulsed Field Ablation-Pulmonary Vein Isolation and Nanosecond Pulse Field Ablation / $c J. Petru, M. Funasako, P. Neuzil
520    9_
$a Pulse field ablation (PFA) has gained attention in the field of atrial fibrillation catheter treatment recently. All currently used or developed technologies use ultrashort pulses (on the order of microseconds). The Emerging CellFX System (Pulse Biosciences, Inc, Inc) utilizes nanosecond PFA (nsPFA) and is thus several orders of magnitude shorter than the initial PFA systems. There are several potential advantages of nsPFA over microsecond PFA such as deeper penetration of the electric field into tissue, creating larger and deeper ablation zones while depositing less overall energy and heat, faster treatment, and less muscle stimulation or nerve capture.
650    _2
$a lidé $7 D006801
650    12
$a venae pulmonales $x chirurgie $7 D011667
650    12
$a katetrizační ablace $x přístrojové vybavení $x metody $7 D017115
650    12
$a fibrilace síní $x chirurgie $7 D001281
650    _2
$a ireverzibilní elektroporace (terapie) $7 D000092723
655    _2
$a časopisecké články $7 D016428
655    _2
$a přehledy $7 D016454
700    1_
$a Funasako, Moritoshi $u Department of Cardiology, Charles University, Na Homolce Hospital, Roentgenova 2, 150 30, Prague 5, Prague, Czech Republic
700    1_
$a Neuzil, Petr $u Department of Cardiology, Charles University, Na Homolce Hospital, Roentgenova 2, 150 30, Prague 5, Prague, Czech Republic
773    0_
$w MED00203263 $t Cardiac electrophysiology clinics $x 1877-9190 $g Roč. 17, č. 2 (2025), s. 273-285
856    41
$u https://pubmed.ncbi.nlm.nih.gov/40412876 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20250708 $b ABA008
991    __
$a 20250731090946 $b ABA008
999    __
$a ok $b bmc $g 2366323 $s 1252547
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2025 $b 17 $c 2 $d 273-285 $e 20250317 $i 1877-9190 $m Cardiac electrophysiology clinics $n Card Electrophysiol Clin $x MED00203263
LZP    __
$a Pubmed-20250708

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...