Something wrong with this record ?
Biomechanical comparison of screw position in variable angle locking plate in intra-articular calcaneal fractures: Cadaveric and radiologic study
V. Baba, L. Capek, L. Kopp, V. Bittner
Language English Country England, Great Britain
Document type Journal Article, Comparative Study
- MeSH
- Biomechanical Phenomena MeSH
- Adult MeSH
- Fractures, Bone * surgery diagnostic imaging physiopathology MeSH
- Intra-Articular Fractures * surgery diagnostic imaging physiopathology MeSH
- Bone Plates * MeSH
- Bone Screws * MeSH
- Middle Aged MeSH
- Humans MeSH
- Cadaver MeSH
- Calcaneus * surgery diagnostic imaging injuries MeSH
- Radiography MeSH
- Retrospective Studies MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Fracture Fixation, Internal * methods instrumentation MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Comparative Study MeSH
BACKGROUND: Lateral plating of calcaneal fractures using variable-angle locking plates is still the golden standard for severely comminuted cases. The aim of this study is to explore the possibilities of improving stability of osteosynthesis by changing screw directions. It provides an assessment and comparison of cadaveric biomechanical experiment with retrospective radiologic data analysis. METHODS: In the cadaveric study 8 intact calcaneus-talus specimens were obtained from 4 deceased donors. Fracture type 2b according to Sanders' classification was created in each specimen and fixed with variable-angle locking plate. The specimens were divided in 2 groups differing in orientation of anterior screws and fixed in PMMA base. A push-in test was performed by a two-column testing machine until gross failure. Retrospective cohort study was performed, reviewing data of 74 patients which underwent surgical treatment of calcaneal fractures with the same construct. Evaluation was performed at scheduled CT and X-Ray controls. Direction of inserted screws and implant failure were noted. FINDINGS: The cadaveric study proved that there is no significant difference in mean failure force between two abovementioned screw configurations in Sanders 2b fracture. A significant difference was observed in initial stiffness. The radiologic retrospective study showed that difference in screw position within all fracture types but type 2b is significant. INTERPRETATION: Screw configuration in the anterior part of variable-angle locking plate appears to affect primary stiffness and stability of the construct. Particularly in more comminuted fractures, screw inserted in the direction of sustentaculum improves the stability and lowers risk of implant failure.
Dep of Clinical Biomechanics Regional Hospital in Liberec Czech Republic
Dep of Technology and Structure Technical University of Liberec Czech Republic
Dep of Traumatology Masaryk Hospital in Usti and Labem Czech Republic
Department of Mathematics Technical University of Liberec Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc25015844
- 003
- CZ-PrNML
- 005
- 20250731091255.0
- 007
- ta
- 008
- 250708e20250423enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.clinbiomech.2025.106534 $2 doi
- 035 __
- $a (PubMed)40288301
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Baba, Vit $u Dep. of Traumatology, Masaryk Hospital in Usti and Labem, Czech Republic; 2(nd) medical faculty, Charles university in Prague, Czech Republic
- 245 10
- $a Biomechanical comparison of screw position in variable angle locking plate in intra-articular calcaneal fractures: Cadaveric and radiologic study / $c V. Baba, L. Capek, L. Kopp, V. Bittner
- 520 9_
- $a BACKGROUND: Lateral plating of calcaneal fractures using variable-angle locking plates is still the golden standard for severely comminuted cases. The aim of this study is to explore the possibilities of improving stability of osteosynthesis by changing screw directions. It provides an assessment and comparison of cadaveric biomechanical experiment with retrospective radiologic data analysis. METHODS: In the cadaveric study 8 intact calcaneus-talus specimens were obtained from 4 deceased donors. Fracture type 2b according to Sanders' classification was created in each specimen and fixed with variable-angle locking plate. The specimens were divided in 2 groups differing in orientation of anterior screws and fixed in PMMA base. A push-in test was performed by a two-column testing machine until gross failure. Retrospective cohort study was performed, reviewing data of 74 patients which underwent surgical treatment of calcaneal fractures with the same construct. Evaluation was performed at scheduled CT and X-Ray controls. Direction of inserted screws and implant failure were noted. FINDINGS: The cadaveric study proved that there is no significant difference in mean failure force between two abovementioned screw configurations in Sanders 2b fracture. A significant difference was observed in initial stiffness. The radiologic retrospective study showed that difference in screw position within all fracture types but type 2b is significant. INTERPRETATION: Screw configuration in the anterior part of variable-angle locking plate appears to affect primary stiffness and stability of the construct. Particularly in more comminuted fractures, screw inserted in the direction of sustentaculum improves the stability and lowers risk of implant failure.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a kostní destičky $7 D001860
- 650 12
- $a patní kost $x chirurgie $x diagnostické zobrazování $x zranění $7 D002111
- 650 12
- $a kostní šrouby $7 D001863
- 650 _2
- $a mrtvola $7 D002102
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a lidé středního věku $7 D008875
- 650 12
- $a vnitřní fixace fraktury $x metody $x přístrojové vybavení $7 D005593
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a dospělí $7 D000328
- 650 12
- $a fraktury kostí $x chirurgie $x diagnostické zobrazování $x patofyziologie $7 D050723
- 650 12
- $a intraartikulární fraktury $x chirurgie $x diagnostické zobrazování $x patofyziologie $7 D057072
- 650 _2
- $a radiografie $7 D011859
- 650 _2
- $a senioři nad 80 let $7 D000369
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a srovnávací studie $7 D003160
- 700 1_
- $a Capek, Lukas $u Dep. of Clinical Biomechanics, Regional Hospital in Liberec, Czech Republic; Dep. of Technology and Structure, Technical University of Liberec, Czech Republic. Electronic address: lukas.capek@nemlib.cz
- 700 1_
- $a Kopp, Lubomir $u Dep. of Traumatology, Masaryk Hospital in Usti and Labem, Czech Republic; 2(nd) medical faculty, Charles university in Prague, Czech Republic
- 700 1_
- $a Bittner, Vaclav $u Department of Mathematics, Technical University of Liberec, Czech Republic
- 773 0_
- $w MED00001120 $t Clinical biomechanics $x 1879-1271 $g Roč. 125 (20250423), s. 106534
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/40288301 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20250708 $b ABA008
- 991 __
- $a 20250731091250 $b ABA008
- 999 __
- $a ok $b bmc $g 2366580 $s 1252969
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2025 $b 125 $c - $d 106534 $e 20250423 $i 1879-1271 $m Clinical biomechanics $n Clin Biomech (Bristol) $x MED00001120
- LZP __
- $a Pubmed-20250708