Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Comparison of structural variants detected by optical mapping with long-read next-generation sequencing

J. Savara, T. Novosád, P. Gajdoš, E. Kriegová

. 2021 ; 37 (20) : 3398-3404. [pub] 20211025

Status minimální Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc25025916

Grantová podpora
NU20-06-00269 Ministry of Health of the Czech Republic
IGA_LF UP_2021_15 Internal Grant Agency of Palacký University
SP2021/94 VSB-Technical University of Ostrava
NU20-06-00269 MZ0 CEP - Centrální evidence projektů

MOTIVATION: Recent studies have shown the potential of using long-read whole-genome sequencing (WGS) approaches and optical mapping (OM) for the detection of clinically relevant structural variants (SVs) in cancer research. Three main long-read WGS platforms are currently in use: Pacific Biosciences (PacBio), Oxford Nanopore Technologies (ONT) and 10x Genomics. Recently, whole-genome OM technology (Bionano Genomics) has been introduced into human diagnostics. Questions remain about the accuracy of these long-read sequencing platforms, how comparable/interchangeable they are when searching for SVs and to what extent they can be replaced or supplemented by OM. Moreover, no tool can effectively compare SVs obtained by OM and WGS. RESULTS: This study compared optical maps of the breast cancer cell line SKBR3 with AnnotSV outputs from WGS platforms. For this purpose, a software tool with comparative and filtering features was developed. The majority of SVs up to a 50 kbp distance variance threshold found by OM were confirmed by all WGS platforms, and ∼99% of translocations and ∼80% of deletions found by OM were confirmed by both PacBio and ONT, with ∼70% being confirmed by 10x Genomics in combination with PacBio and/or ONT. Interestingly, long deletions (>100 kbp) were detected only by 10x Genomics. Regarding insertions, ∼74% was confirmed by PacBio and ONT, but none by 10x Genomics. Inversions and duplications detected by OM were not detected by WGS. Moreover, the tool enabled the confirmation of SVs that overlapped in the same gene(s) and was applied to the filtering of disease-associated SVs. AVAILABILITY AND IMPLEMENTATION: https://github.com/novosadt/om-annotsv-svc.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25025916
003      
CZ-PrNML
005      
20251212152605.0
007      
ta
008      
251210s2021 xr f 000 0|eng||
024    7_
$a 10.1093/bioinformatics/btab359 $2 doi
035    __
$a (PubMed)33983367
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Savara, Jakub $u Department of Computer Science, VSB-Technical University of Ostrava, Ostrava, 708 00, Czech Republic $u Department of Immunology, Faculty of Medicine and Dentistry, Palacký University in Olomouc and University Hospital Olomouc, 779 00, Olomouc, Czech Republic $1 https://orcid.org/0000000330677867
245    10
$a Comparison of structural variants detected by optical mapping with long-read next-generation sequencing / $c J. Savara, T. Novosád, P. Gajdoš, E. Kriegová
520    9_
$a MOTIVATION: Recent studies have shown the potential of using long-read whole-genome sequencing (WGS) approaches and optical mapping (OM) for the detection of clinically relevant structural variants (SVs) in cancer research. Three main long-read WGS platforms are currently in use: Pacific Biosciences (PacBio), Oxford Nanopore Technologies (ONT) and 10x Genomics. Recently, whole-genome OM technology (Bionano Genomics) has been introduced into human diagnostics. Questions remain about the accuracy of these long-read sequencing platforms, how comparable/interchangeable they are when searching for SVs and to what extent they can be replaced or supplemented by OM. Moreover, no tool can effectively compare SVs obtained by OM and WGS. RESULTS: This study compared optical maps of the breast cancer cell line SKBR3 with AnnotSV outputs from WGS platforms. For this purpose, a software tool with comparative and filtering features was developed. The majority of SVs up to a 50 kbp distance variance threshold found by OM were confirmed by all WGS platforms, and ∼99% of translocations and ∼80% of deletions found by OM were confirmed by both PacBio and ONT, with ∼70% being confirmed by 10x Genomics in combination with PacBio and/or ONT. Interestingly, long deletions (>100 kbp) were detected only by 10x Genomics. Regarding insertions, ∼74% was confirmed by PacBio and ONT, but none by 10x Genomics. Inversions and duplications detected by OM were not detected by WGS. Moreover, the tool enabled the confirmation of SVs that overlapped in the same gene(s) and was applied to the filtering of disease-associated SVs. AVAILABILITY AND IMPLEMENTATION: https://github.com/novosadt/om-annotsv-svc.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Novosád, Tomáš $u Department of Computer Science, VSB-Technical University of Ostrava, Ostrava, 708 00, Czech Republic $1 https://orcid.org/000000032291261X
700    1_
$a Gajdoš, Petr $u Department of Computer Science, VSB-Technical University of Ostrava, Ostrava, 708 00, Czech Republic $1 https://orcid.org/0000000318313489
700    1_
$a Kriegová, Eva $u Department of Immunology, Faculty of Medicine and Dentistry, Palacký University in Olomouc and University Hospital Olomouc, 779 00, Olomouc, Czech Republic $1 https://orcid.org/0000000289694197
773    0_
$w MED00008115 $t Bioinformatics $x 1367-4811 $g Roč. 37, č. 20 (2021), s. 3398-3404
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33983367 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y -
990    __
$a 20251210 $b ABA008
999    __
$a min $b bmc $g 2446418 $s 1264114
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2021 $b 37 $c 20 $d 3398-3404 $e 20211025 $i 1367-4811 $m Bioinformatics (Oxford, England) $n Bioinformatics $x MED00008115
GRA    __
$a NU20-06-00269 $p Ministry of Health of the Czech Republic
GRA    __
$a IGA_LF UP_2021_15 $p Internal Grant Agency of Palacký University
GRA    __
$a SP2021/94 $p VSB-Technical University of Ostrava
GRA    __
$a NU20-06-00269 $p MZ0
LZP    __
$a AZV-2023-Pubmed-20251210

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...