Comparison of oriented and random antibody immobilization in immunoaffinity chromatography of cytokinins

. 1998 Jun 19 ; 811 (1-2) : 77-84.

Jazyk angličtina Země Nizozemsko Médium print

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/pmid09691302
Odkazy

PubMed 9691302
DOI 10.1016/s0021-9673(98)00210-6
PII: S0021-9673(98)00210-6
Knihovny.cz E-zdroje

Immunosorbents for the plant hormones cytokinins prepared by random antibody immobilization (to Affi-Gel 10) and by oriented approach via oxidized carbohydrate moieties on the Fc region (to Affi-Gel Hz or hydrazide derivative of Perloza MT 200) have been compared. Both approaches yielded immunosorbents with high dynamic capacity (ca. 5-10 nmol ml gel-1). Oriented antibody immobilization did not exhibit crucial effects in the case of low-molecular-mass cytokinins. Antibodies immobilized via a spacer to Affi-Gel 10 have probably enough conformational freedom to enable good accessibility to cytokinins. The sorbents were used in analysis of endogenous cytokinins in maize seeds. In phosphatase treated samples trans-zeatin and its riboside were predominant.