Total knee arthroplasty implanted with and without kinematic navigation

. 2003 ; 27 (6) : 366-9. [epub] 20030826

Jazyk angličtina Země Německo Médium print-electronic

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid12942197

Between September 2000 and February 2002 we inserted 120 total knee arthroplasties. In 60 patients we used the standard technique, and in 60 patients we used the OrthoPilot navigation system. Postoperatively all patients had standing long radiographs of the lower extremity from the hip joint to the ankle. We considered the ideal value of the anatomic lateral tibiofemoral angle (LTFA) to be 174 degrees. In the standard group the mean value of LTFA was 174.9 degrees and in the navigation group 174.3 degrees. A deviation between 0 degrees and 2 degrees from the ideal value was seen in 42 cases in the standard group and in 53 cases in the navigation group. In the standard group 18 cases had a deviation of more than 2.1 degrees, whereas there were only seven cases in the navigation group with a deviation exceeding 2.1 degrees. There were no complications related to the use of the navigation system. The system affords a possibility to place femoral and tibial components precisely with less axis deviation than with the conventional technique.

Entre septembre 2000 et février 2002 nous avons implanté 120 arthroplasties totales du genou. Chez 60 malades nous avons utilisé la technique standard et chez 60 malades nous avons utilisé le système de navigation OrthoPilot. Après l'opération tous les malades avaient une grande radiographie du membre inférieur, de la hanche à la cheville. Nous avons considéré que la valeur idéale de l'angle tibiofémoral latéral (LTFA) était de 174°. Dans le groupe standard la valeur moyenne de LTFA était 174.9°, dans le groupe navigation de 174.3°. Une déviation entre 0° et 2° de la valeur idéale a été notée dans 42 cas dans le groupe standard et dans 53 cas dans le groupe navigation. Dans le groupe standard 18 cas avaient une déviation de plus que 2.1°, alors qu'il y avait seulement 7 cas dans le groupe navigation avec une déviation dépassant 2.1°. Il n'y avait pas de complications relatives à l'usage du système de navigation. Le système offre une possibilité de placer les composants fémoral et tibial précisément avec moins de déviation de l'axe qu'avec la technique conventionnelle.

Zobrazit více v PubMed

Bargren Clin Orthop. 1983;173:178.

Delp Clin Orthop. 1998;354:49. PubMed

Elloy J Biomed. 1992;14:363.

Gossé F, Brack C, Gotte H, Roth M, Ruhmann O, Schweikard A, Vahldiek M (1997) Roboterunterstützung in der Knieendoprothetik. Orthopäde 26:258–266 PubMed

Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg [Br] 73:709–714 PubMed

Jenny Z Orthop. 2001;139:117. doi: 10.1055/s-2001-15041. PubMed DOI

Katz MM, Hungerford DS, Krakow KA, Lennox DW (1987) Results of total knee arthroplasty after failed proximal tibial osteotomy for osteoarthritis. J Bone Joint Surg [Am] 69:225–233 PubMed

Lonner Clin Orthop. 1996;331:102. PubMed

Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg [Am] 59:77–79 PubMed

Mielke Z Orthop. 2001;139:100.

Oswald J Arthroplasty. 1993;8:419. PubMed

Patel Int Ortop. 1991;15:209. PubMed

Petersen J Arthroplasty. 1988;1:67.

Prakash U, Wigderowitz CA, McGurty DW, Rowley DI (2001) Computerised measurement of tibiofemoral alignment. J Bone Joint Surg [Br] 83:819–824 PubMed

Ritter Clin Orthop. 1994;299:153.

Saleh KJ, Sherman P, Katkin P, Windsor R et al (2001) Total knee arthroplasty after open reduction and internal fixation of fractures of the tibial plateau. J Bone Joint Surg [Am] 83:1144–1148 PubMed

Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg [Am] 84:90–98 PubMed

Toksvig-Larsen S et al (1998) Fixation of the tibial component of total knee arthroplasty after high tibial osteotomy. J Bone Joint Surg [Br] 80:295–297 PubMed

Townley Clin Orthop. 1985;192:82. PubMed

Waugh MTW (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg [Br] 67:551–556 PubMed

Windsor RE, Insall JN, Vince KG (1988) Technical considerations of total knee arthroplasty after proximal tibial osteotomy. J Bone Joint Surg [Am] 70:547–555 PubMed

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...