Comparison of early diastolic mitral annular velocity and flow propagation velocity in detection of mild to moderate left ventricular diastolic dysfunction
Language English Country Great Britain, England Media print
Document type Comparative Study, Journal Article
PubMed
15147662
DOI
10.1016/j.euje.2003.09.004
PII: S1525216703000933
Knihovny.cz E-resources
- MeSH
- Echocardiography, Doppler, Color methods MeSH
- Time Factors MeSH
- Diastole physiology MeSH
- Adult MeSH
- Ventricular Dysfunction, Left diagnostic imaging physiopathology MeSH
- Middle Aged MeSH
- Humans MeSH
- Mitral Valve physiopathology MeSH
- Echocardiography, Doppler, Pulsed methods MeSH
- Blood Flow Velocity MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Publication type
- Journal Article MeSH
- Comparative Study MeSH
BACKGROUND: Pulsed wave tissue Doppler echocardiography (PW-TDE) and color M-mode are new Doppler methods for left ventricular (LV) diastolic function assessment. To date, few studies have compared the data obtained by these methods in the same series of patients and compared them to the current clinical reference method of detecting LV diastolic function. AIMS: To determine the utility of PW-TDE and color M-mode parameters in the assessment of LV diastolic function in the typical patient population encountered in daily clinical practice and to compare their discriminating power. METHODS: Early diastolic septal mitral annular velocity (Em) determined by PW-TDE and color M-mode flow propagation velocity (Vp) were measured in 86 male patients and compared to LV filling patterns obtained using standard Doppler indices. Values of Em < 0.08 m s(-1) and Vp < 0.5 m s(-1) were considered as markers of abnormal LV diastolic function. RESULTS: A value of Em < 0.08 m s(-1) distinguished mild to moderate LV diastolic dysfunction with higher sensitivity and specificity than Vp < 0.5 m s(-1) (96% and 87% vs. 73% and 84%, respectively). A comparison of receiver operating characteristic curves showed a significant difference for areas under the curve in favor of Em (P < 0.01). In a stepwise multiple logistic regression analysis, a pseudonormal filling pattern and an EF > 60% were identified as significant predictors of Vp false negative results (p < 0.05). CONCLUSIONS: Em appears to be superior to Vp in the detection of mild to moderate LV diastolic dysfunction. Vp failed to detect abnormal LV diastolic function in particular in patients with preserved LV systolic function and a pseudonormal filling pattern type.
References provided by Crossref.org