Air Kerma Rate estimation by means of in-situ gamma spectrometry: a Bayesian approach

. 2010 Apr-May ; 68 (4-5) : 804-6. [epub] 20090925

Jazyk angličtina Země Velká Británie, Anglie Médium print-electronic

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid19914079
Odkazy

PubMed 19914079
DOI 10.1016/j.apradiso.2009.09.062
PII: S0969-8043(09)00599-5
Knihovny.cz E-zdroje

Bayesian inference is used to determine the Air Kerma Rate based on in-situ gamma spectrum measurement performed with an NaI(Tl) scintillation detector. The procedure accounts for uncertainties in the measurement and in the mass energy transfer coefficients needed for the calculation. The WinBUGS program (Spiegelhalter et al., 1999) was used. The results show that the relative uncertainties in the Air Kerma estimate are of about 1%, and that the choice of unfolding procedure may lead to an estimate systematic error of 3%.