Results of the 2010 National Radiation Protection Institute intercomparison of radon and its short-lived decay product continuous monitors

. 2011 May ; 145 (2-3) : 273-9. [epub] 20110406

Jazyk angličtina Země Anglie, Velká Británie Médium print-electronic

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/pmid21471124

During the Sixth European Conference on Protection Against Radon at Home and at Work held in autumn 2010 in Prague, the first intercomparison of continuous radon and its short-lived decay product monitors was organised and held by the Natural Radiation Division of the National Radiation Protection Institute (NRPI) in Prague. Eight laboratories submitted eight continuous radon monitors, two electronic monitors, three passive integral systems based on charcoal and three continuous radon short-lived decay product monitors. The intercomparison included exposures to both the radon gas concentration and equivalent equilibrium radon concentration (EEC) under different ambient conditions similar to the ones in dwellings. In particular, the influence of the equilibrium factor F, unattached fraction of EEC f(p) and absolute air humidity were investigated. The results of the radon gas measurements were performed on a calibration level of about 8 kBq m(-3). The results of all monitors were compared with the reference NRPI monitor.