Determination of the deuterium abundances in water from 156 to 10,000 ppm by SIFT-MS
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu časopisecké články
- MeSH
- chemické modely MeSH
- dechové testy MeSH
- deuterium analýza metabolismus MeSH
- hmotnostní spektrometrie metody MeSH
- tělesná voda MeSH
- termodynamika MeSH
- voda chemie MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- deuterium MeSH
- voda MeSH
In response to a need for the measurement of the deuterium (D) abundance in water and aqueous liquids exceeding those previously recommended when using flowing afterglow mass spectrometry (FA-MS) and selected ion flow tube mass spectrometry (SIFT-MS) (i.e. 1000 parts per million, ppm), we have developed the theory of equilibrium isotopic composition of the product ions on which these analytical methods are based to encompass much higher abundances of D in water up to 10,000 ppm (equivalent to 1%). This has involved an understanding of the number density distributions of the H, D, (16)O, (17)O and (18)O isotopes in the isotopologues of H(3)O(+)(H(2)O)(3) hydrated ions (i.e. H(9)O (4) (+) cluster ions) at mass-to-charge ratios (m/z) of 73, 74 and 75, the relative ion number densities of which represent the basis of FA-MS and SIFT-MS analyses of D abundance. Specifically, an extended theory has been developed that accounts for the inclusion of D atoms in the m/z 75 ions, which increasingly occurs as D abundance in the water is increased, and which is used as a reference signal for the m/z 74 ions in the measurement of D abundance. In order to investigate the efficacy of this theory, experimental measurements of deuterium abundance in standard mixtures were made by the SIFT-MS technique using two similar instruments and the results compared with the theory. It is demonstrated that the parameterization of experimental data can be used to formulate a simple calculation algorithm for real-time SIFT-MS measurements of D abundance to an accuracy of 1% below 1000 ppm and degrades to about 2% at 10,000 ppm.
Zobrazit více v PubMed
Clin J Am Soc Nephrol. 2010 Aug;5(8):1463-70 PubMed
Physiol Meas. 2001 Nov;22(4):651-9 PubMed
Nephrol Dial Transplant. 2008 Jun;23(6):2064-70 PubMed
J Am Soc Nephrol. 2005 Feb;16(2):437-43 PubMed
Clin J Am Soc Nephrol. 2009 Nov;4(11):1791-8 PubMed
Rapid Commun Mass Spectrom. 2003;17(10):1017-29 PubMed
Mass Spectrom Rev. 2011 Mar-Apr;30(2):236-67 PubMed
BMC Res Notes. 2008 Jul 10;1:41 PubMed
J Am Soc Mass Spectrom. 2000 Oct;11(10):866-75 PubMed
J Phys Chem B. 2010 May 6;114(17):5755-63 PubMed
Mass Spectrom Rev. 2005 Sep-Oct;24(5):661-700 PubMed
Am J Clin Nutr. 2002 Dec;76(6):1295-301 PubMed
Rapid Commun Mass Spectrom. 2001;15(1):25-32 PubMed
Kidney Int. 2003 Nov;64(5):1911-5 PubMed
Rapid Commun Mass Spectrom. 2001;15(11):867-72 PubMed