• This record comes from PubMed

Progress in SIFT-MS: breath analysis and other applications

. 2011 Mar-Apr ; 30 (2) : 236-67. [epub] 20100720

Language English Country United States Media print-electronic

Document type Journal Article, Research Support, Non-U.S. Gov't, Review

The development of selected ion flow tube mass spectrometry, SIFT-MS, is described from its inception as the modified very large SIFT instruments used to demonstrate the feasibility of SIFT-MS as an analytical technique, towards the smaller but bulky transportable instruments and finally to the current smallest Profile 3 instruments that have been located in various places, including hospitals and schools to obtain on-line breath analyses. The essential physics and engineering principles are discussed, which must be appreciated to design and construct a SIFT-MS instrument. The versatility and sensitivity of the Profile 3 instrument is illustrated by typical mass spectra obtained using the three precursor ions H(3)O(+), NO(+) and O(2)(+)·, and the need to account for differential ionic diffusion and mass discrimination in the analytical algorithms is emphasized to obtain accurate trace gas analyses. The performance of the Profile 3 instrument is illustrated by the results of several pilot studies, including (i) on-line real time quantification of several breath metabolites for cohorts of healthy adults and children, which have provided representative concentration/population distributions, and the comparative analyses of breath exhaled via the mouth and nose that identify systemic and orally-generated compounds, (ii) the enhancement of breath metabolites by drug ingestion, (iii) the identification of HCN as a marker of Pseudomonas colonization of the airways and (iv) emission of volatile compounds from urine, especially ketone bodies, and from skin. Some very recent developments are discussed, including the quantification of carbon dioxide in breath and the combination of SIFT-MS with GC and ATD, and their significance. Finally, prospects for future SIFT-MS developments are alluded to.

References provided by Crossref.org

Newest 20 citations...

See more in
Medvik | PubMed

Recent developments and applications of selected ion flow tube mass spectrometry (SIFT-MS)

. 2025 Mar-Apr ; 44 (2) : 101-134. [epub] 20230212

Combining Thermal Desorption with Selected Ion Flow Tube Mass Spectrometry for Analyses of Breath Volatile Organic Compounds

. 2024 Jan 30 ; 96 (4) : 1397-1401. [epub] 20240120

Robust Automated SIFT-MS Quantitation of Volatile Compounds in Air Using a Multicomponent Gas Standard

. 2023 Dec 06 ; 34 (12) : 2630-2645. [epub] 20231121

How to Use Ion-Molecule Reaction Data Previously Obtained in Helium at 300 K in the New Generation of Selected Ion Flow Tube Mass Spectrometry Instruments Operating in Nitrogen at 393 K

. 2023 Jul 25 ; 95 (29) : 11157-11163. [epub] 20230716

Selected ion flow tube mass spectrometry for targeted analysis of volatile organic compounds in human breath

. 2021 Jul ; 16 (7) : 3419-3438. [epub] 20210604

Quantification of volatile metabolites in exhaled breath by selected ion flow tube mass spectrometry, SIFT-MS

. 2020 Apr ; 16 () : 18-24. [epub] 20200213

Exhaled breath hydrogen cyanide as a marker of early Pseudomonas aeruginosa infection in children with cystic fibrosis

. 2015 Oct ; 1 (2) : . [epub] 20151116

Determination of the deuterium abundances in water from 156 to 10,000 ppm by SIFT-MS

. 2011 Jan ; 22 (1) : 179-86. [epub] 20110121

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...