The influence of orifice height on flow rate of powder excipients

. 2011 Dec ; 66 (12) : 953-5.

Jazyk angličtina Země Německo Médium print

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/pmid22312701

The influence of the orifice height of a cylindrical, flat-bottomed hopper on the mass flow rate of the free-flowable size fractions of sodium chloride and boric acid was investigated. It was observed that a zone of sudden acceleration of the mass flow under gravity occurred when a critical orifice height had been achieved. Based on the results, an orifice diameter equal to 12 mm with a height of between 8-16 mm is recommended for the faster flow of sodium chloride while an orifice diameter equal to 8 mm with a height of less than 8mm is appropriate for the slower flow of boric acid. In summary, the orifice height should be taken into consideration as an important parameter of a cylindrical test hopper in order to obtain a reproducible and comparable mass flow as the single-point characteristic of powder flowability.