Rapid HILIC method with fluorescence detection using derivatization reaction utilizing o-phthaldialdehyde for determination of degradation product of aliskiren

. 2012 Jul ; 66 () : 359-64. [epub] 20120317

Jazyk angličtina Země Anglie, Velká Británie Médium print-electronic

Typ dokumentu časopisecké články, validační studie

Perzistentní odkaz   https://www.medvik.cz/link/pmid22475518
Odkazy

PubMed 22475518
DOI 10.1016/j.jpba.2012.03.015
PII: S0731-7085(12)00138-0
Knihovny.cz E-zdroje

A rapid procedure based on direct extraction and HILIC separation of aliskiren (ALI) degradation product - 3-amino-2,2-dimethylpropanamide (ADPA) with fluorescence detection has been developed. The formation of ADPA from ALI under different conditions was studied. The evaluation of HILIC method robustness was performed using multifactorial experiments with fixed factors (one-level Plackett-Burman design). XBridge HILIC column with isocratic elution using mobile phase 10 mM K(2)HPO(4) pH 7.2-acetonitrile (26:74; v/v) was employed. Fluorescence detection after post column derivatization using o-phthaldialdehyde (OPA) reagent was performed at excitation and emission wavelength of 345 nm and 450 nm, respectively. The reported method has an advantage of a simple sample pre-treatment and quick and very sensitive measurement. The method was successfully applied for the analysis of commercially available ALI samples.

Citace poskytuje Crossref.org

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...