Intra- and interlaboratory variability of paroxysmal nocturnal hemoglobinuria testing by flow cytometry following the 2012 Practical Guidelines for high-sensitivity paroxysmal nocturnal hemoglobinuria testing
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
23325604
DOI
10.1002/cyto.b.21075
Knihovny.cz E-zdroje
- MeSH
- antigeny CD59 krev MeSH
- erytrocyty patologie MeSH
- leukocyty patologie MeSH
- lidé MeSH
- paroxysmální hemoglobinurie diagnóza patologie MeSH
- počet leukocytů MeSH
- průtoková cytometrie * MeSH
- referenční standardy * MeSH
- směrnice pro lékařskou praxi jako téma MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- antigeny CD59 MeSH
BACKGROUND: Sutherland et al. recently published the Practical Guidelines for high-sensitivity detection of paroxysmal nocturnal hemoglobinuria (PNH) clones by flow cytometry (FCM), containing concise protocols for PNH testing. METHODS: Using this approach, we studied the intra- and interlaboratory variability observed in a multicenter study in which fresh blood samples containing three clinically relevant PNH clone sizes within the granulocytic, monocytic, and red blood cell (RBC) populations were shipped to each participating center. RESULTS: Coefficients of variation (CVs) for precision/reproducibility analysis ranged from 0.01%/0.02% to 0.48%/0.45% (big clone), from 0.69%/1.52% to 4.24%/5.80% (small-intermediate clone), from 1.47%/3.91% to 15.01% /17.83% (minor clone) for PNH white blood cells (WBCs) and from 0.24%/0.48% to 1.76%/1.83% (big clone), from 0.80%/1.14% to 2.39%/4.45% (small-intermediate clone), from 1.09%/3.36% to 10.54%/10.23% (minor clone) for PNH RBCs, respectively. Linear regression analysis showed excellent performance correlation between centers (r > 0.99), Wilcoxon rank test revealed no statistically significant differences for PNH granulocytes, monocytes, and RBCs (P > 0.05%), Bland-Altman analysis demonstrated good performance agreement for all target PNH clones (mean bias ranging from -1.47 to 0.71). CONCLUSION: Our results demonstrate very good intra- and interlaboratory performance characteristics for both precision and reproducibility analyses and excellent correlation and agreement between centers for all target PNH clone sizes. Our data confirm the reliability and robustness of the recently published Practical Guidelines approach for high sensitivity PNH testing by flow cytometry and suggest that such an approach represents an excellent basis for standardization of PNH testing by flow cytometry.