• This record comes from PubMed

Estimation of ion competition via correlated responsivity offset in linear ion trap mass spectrometry analysis: theory and practical use in the analysis of cyanobacterial hepatotoxin microcystin-LR in extracts of food additives

. 2013 ; 2013 () : 414631. [epub] 20130326

Language English Country United States Media print-electronic

Document type Journal Article, Research Support, Non-U.S. Gov't

Responsivity is a conversion qualification of a measurement device given by the functional dependence between the input and output quantities. A concentration-response-dependent calibration curve represents the most simple experiment for the measurement of responsivity in mass spectrometry. The cyanobacterial hepatotoxin microcystin-LR content in complex biological matrices of food additives was chosen as a model example of a typical problem. The calibration curves for pure microcystin and its mixtures with extracts of green alga and fish meat were reconstructed from the series of measurement. A novel approach for the quantitative estimation of ion competition in ESI is proposed in this paper. We define the correlated responsivity offset in the intensity values using the approximation of minimal correlation given by the matrix to the target mass values of the analyte. The estimation of the matrix influence enables the approximation of the position of a priori unknown responsivity and was easily evaluated using a simple algorithm. The method itself is directly derived from the basic attributes of the theory of measurements. There is sufficient agreement between the theoretical and experimental values. However, some theoretical issues are discussed to avoid misinterpretations and excessive expectations.

See more in PubMed

Fouquet T, Charles L. Distinction and quantitation of sugar isomers in ternary mixtures using the kinetic method. Journal of the American Society for Mass Spectrometry. 2010;21(1):60–67. PubMed

Holčapek M, Volná K, Jandera P, et al. Effects of ionpairing reagents on the electrospray signal suppression of sulphonated dyes and intermediates. Journal of Mass Spectrometry. 2004;39:43–50. PubMed

Herrera LC, Grossert JS, Ramaley L. Quantitative aspects of and ionization mechanisms in positive-ion atmospheric pressure chemical ionization mass spectrometry. Journal of the American Society for Mass Spectrometry. 2008;19(12):1926–1941. PubMed

Shulaev V. Metabolomics technology and bioinformatics. Briefings in Bioinformatics. 2006;7(2):128–139. PubMed

Gustavsson SÅ, Samskog J, Markides KE, Långström BJ. Studies of signal suppression in liquid chromatography-electrospray ionization mass spectrometry using volatile ion-pairing reagents. Journal of Chromatography A. 2001;937(1-2):41–47. PubMed

Tanaka N, Nagasaka K, Komatsu Y. Selected reaction monitoring by linear ion-trap mass spectrometry can effectively be applicable to simultaneous quantification of multiple peptides. Biological and Pharmaceutical Bulletin. 2011;34(1):135–141. PubMed

Thomsen V, Schatzlein D, Mercuro D. Limits of detection in spectroscopy. Spectroscopy. 2003;18(12):112–114.

Ingle JD., Jr. Sensitivity and limit of detection in quantitative spectrometric methods. Journal of Chemical Education. 1974;51(2):100–105.

Van Wagoner RM, Drummond AK, Wright JLC. Biogenetic diversity of cyanobacterial metabolites. Advances in Applied Microbiology. 2007;61:89–217. PubMed

Welker M, Maršálek B, Šejnohová L, von Döhren H. Detection and identification of oligopeptides in Microcystis (cyanobacteria) colonies: toward an understanding of metabolic diversity. Peptides. 2006;27(9):2090–2103. PubMed

Welker M, von Döhren H. Cyanobacterial peptides—Nature's own combinatorial biosynthesis. FEMS Microbiology Reviews. 2006;30(4):530–563. PubMed

Vezie C, Brient L, Sivonen K, Bertru G, Lefeuvre JC, Salkinoja-Salonen M. Variation of microcystin content of cyanobacterial blooms and isolated strains in Lake Grand-Lieu (France) Microbial Ecology. 1998;35(2):126–135. PubMed

Sivonen K. Cyanobacterial toxins and toxin production. Phycologia. 1996;35:12–24.

MacKintosh C, Beattie KA, Klumpp S, Cohen P, Codd GA. Cyanobacterial microcystin-LR is a potent and specific inhibitor of protein phosphatases 1 and 2A from both mammals and higher plants. FEBS Letters. 1990;264(2):187–192. PubMed

Miura GA, Leclaire RD, Templeton CB, Pace JG. Enhanced hepatotoxicity of microcystin in fasted rats. The FASEB Journal. 1988;2:p. 1351.

Nyakairu GWA, Nagawa CB, Mbabazi J. Assessment of cyanobacteria toxins in freshwater fish: a case study of Murchison Bay (Lake Victoria) and Lake Mburo, Uganda. Toxicon. 2010;55(5):939–946. PubMed

An J, Carmichael WW. Use of a colorimetric protein phosphatase inhibition assay and enzyme linked immunosorbent assay for the study of microcystins and nodularins. Toxicon. 1994;32(12):1495–1507. PubMed

Chu FS, Huang X, Wei RD. Enzyme-linked immunosorbent assay for microcystins in blue-green algal blooms. Journal of the Association of Official Analytical Chemists. 1990;73(3):451–456. PubMed

McDermott CM, Feola R, Plude J. A novel immunoassay for detection of cyanobacterial toxin (microcystin) in water. Toxicon. 1995;33(11):1433–1442. PubMed

Dell'Aversano C, Eaglesham GK, Quilliam MA. Analysis of cyanobacterial toxins by hydrophilic interaction liquid chromatography-mass spectrometry. Journal of Chromatography A. 2004;1028(1):155–164. PubMed

Karlsson K, Sipiä V, Kankaanpää H, Meriluoto J. Mass spectrometric detection of nodularin and desmethylnodularin in mussels and flounders. Journal of Chromatography B. 2003;784(2):243–253. PubMed

Urban J, Vaněk J, Soukup J, Štys D. Expertomica metabolite profiling: getting more information from LC-MS using the stochastic systems approach. Bioinformatics. 2009;25(20):2764–2767. PubMed

Glatting G, Kletting P, Reske SN, Hohl K, Ring C. Choosing the optimal fit function: comparison of the Akaike information criterion and the F-test. Medical Physics. 2007;34(11):4285–4292. PubMed

Li W, Nyholt DR. Marker selection by Akaike information criterion and Bayesian information criterion. Genetic Epidemiology. 2001;21(1):S272–S277. PubMed

Forni S, Piles M, Blasco A, et al. Comparison of different nonlinear functions to describe Nelore cattle growth. Journal of Animal Science. 2009;87(2):496–506. PubMed

IUPAC. Compendium of chemical terminology. In: McNaught AD, Wilkinson A, editors. The Gold Book. 2nd edition. Oxford, UK: Blackwell Scientific Publications; 1997. created by M. Nic, J. Jirat, B. Kosata, updates compiled by A. Jenkins, XML on-line corrected version, 2006, http://goldbook.iupac.org.

Armbruster DA, Tillman MD, Hubbs LM. Limit of detection (LOD)/limit of quantitation (LOQ): comparison of the empirical and the statistical methods exemplified with GC-MS assays of abused drugs. Clinical Chemistry. 1994;40(7):1233–1238. PubMed

Armbruster DA, Pry T. Limit of blank, limit of detection and limit of quantitation. The Clinical Biochemist Reviews. 2008;29(supplement 1):S49–S52. PubMed PMC

Analytical detection guidance & Laboratory guide for determining method detection limits, Wisconsin department of natural resources, Laboratory certification program, PUBL-TS-056-96, 1996.

Garner FC, Robertson GL. Evaluation of detection limit estimators. Chemometrics and Intelligent Laboratory Systems. 1988;3(1-2):53–59.

van der Voet H. Detection limits. In: El-Shaarawi AH, Piegorsch WW, editors. Encyclopedia of Environmetrics. Vol. 1. Chichester, UK: John Wiley & Sons; 2002. pp. 504–515.

Olivieri AC, Faber NM, Ferré J, Boqué R, Kalivas JH, Mark H. Guidelines for calibration in analytical chemistry Part 3. Uncertainty estimation and figures of merit for multivariate calibration. Pure and Applied Chemistry. 2006;78(3):633–661.

Boqué R, Larrechi MS, Rius FX. Multivariate detection limits with fixed probabilities of error. Chemometrics and Intelligent Laboratory Systems. 1999;45(1-2):397–408.

Reed J. Curve Fitting, Lessons on Introduction to Statistics and Probability. 2000, http://staff.argyll.epsb.ca/jreed/

Faber NM, Boqué R. Limits of detection in spectroscopy. Spectroscopy. 2003;18:112–114.

Berlizov AN. Limits of detection in the presence of the correlated background. Journal of Radioanalytical and Nuclear Chemistry. 2007;271(2):363–370.

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...