Immunomagnetic molecular probe with UHPLC-MS/MS: a promising way for reliable bronchial asthma diagnostics based on quantification of cysteinyl leukotrienes
Language English Country England, Great Britain Media print-electronic
Document type Controlled Clinical Trial, Journal Article, Research Support, Non-U.S. Gov't, Validation Study
PubMed
23644905
DOI
10.1016/j.jpba.2013.03.026
PII: S0731-7085(13)00144-1
Knihovny.cz E-resources
- MeSH
- Asthma diagnosis drug therapy physiopathology MeSH
- Breath Tests MeSH
- Glucocorticoids therapeutic use MeSH
- Spectrometry, Mass, Electrospray Ionization methods MeSH
- Immunomagnetic Separation methods MeSH
- Leukotriene C4 analysis MeSH
- Leukotriene D4 analysis MeSH
- Leukotriene E4 analysis MeSH
- Middle Aged MeSH
- Humans MeSH
- Reproducibility of Results MeSH
- Sensitivity and Specificity MeSH
- Case-Control Studies MeSH
- Tandem Mass Spectrometry methods MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Publication type
- Journal Article MeSH
- Controlled Clinical Trial MeSH
- Research Support, Non-U.S. Gov't MeSH
- Validation Study MeSH
- Names of Substances
- Glucocorticoids MeSH
- Leukotriene C4 MeSH
- Leukotriene D4 MeSH
- Leukotriene E4 MeSH
A sensitive and precise method for simultaneous quantification of cysteinyl leukotrienes (=cys LTs) - leukotriene C4 (=LTC4), leukotriene D4 (=LTD4) and leukotriene E4 (=LTE4) - essential biomarkers of bronchial asthma present in exhaled breath condensate (=EBC) was developed. An immunomagnetic molecular probe was prepared by anchoring cysteinyl leukotrienes antibody on the surface of functionalized monodispersed magnetic particles and used to selectively isolate cys LTs from biological matrices - EBC, plasma and urine. Immobilization and the immunoaffinity capture procedures were optimized to maximize the amount of separated cys LTs, which were detected "off-beads" after acidic elution by UHPLC-ESI-MS/MS operated in a multiple reaction monitoring mode. The developed method was characterized with high precision ≤13.6% (intra-day precision determined as RSD) and ≤14.5% (inter-day precision determined as RSD), acceptable accuracy ≤18.5% (determined as RE), and high recovery of immunoseparation (≥93.1%) in aforementioned biological matrices. The applicability of the method was demonstrated on EBC, plasma and urine clinical samples of patients with various subtypes of bronchial asthma (occupational, steroid-resistant, moderate with and without corticosteroids therapy) and healthy subjects where reasonable differences in cys LTs concentration levels were found. Combining extremely selective immunomagnetic separation with highly sensitive and precise detection step, the developed method was used to aid diagnosis, predict the most effective therapy, and monitor the response to treatment. The detection of elevated inflammatory mediators (cys LTs) in EBC of subjects with relatively asymptomatic asthma and normal pulmonary function tests could offer a novel way for monitoring the lung inflammation and perhaps initiating treatment in an earlier stage.
References provided by Crossref.org