The effect of the size of a conical hopper aperture on the parameters of the flow equation of sorbitol and its size fractions

. 2015 Spring ; 64 (1-2) : 14-8.

Jazyk angličtina Země Česko Médium print

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid26084644
Odkazy

PubMed 26084644
PII: 52404
Knihovny.cz E-zdroje

Determination of the rate of gravitational flow through a hopper aperture is one of the most widely used methods for the evaluation of flowability properties of pharmaceutical materials. This work studies the influence of the diameter of a conical hopper aperture in the range of 0.6-1.5 cm on the mass flow rate Q (g/s) of the pharmaceutical excipient, sorbitol, for direct compression (Merisorb 200, MS 200) and its size fractions in the range of 0.080-0.400 mm in order to recommend the appropriate aperture size for testing. Non-linear dependence of the flow rate on the aperture diameter is modeled by the Jones-Pilpel power equation. Using the actual parameters of the power equation, the precision of the mass flow rate prediction was the basic criterion in optimization of the orifice diameter. It was detected experimentally that for the evaluation of the flow rate of MS 200 and its size fractions in the range used a 1.0 cm aperture is recommended, which allows the most precise prediction of the flow rate.Key words: particulate material excipient, flow equation conical hopper size fraction.