Improved quality of life after treatment of prolonged asystole during breath holding spells with a cardiac pacemaker
Status PubMed-not-MEDLINE Language English Country India Media print
Document type Journal Article
PubMed
26085761
PubMed Central
PMC4453178
DOI
10.4103/0974-2069.154142
PII: APC-8-113
Knihovny.cz E-resources
- Keywords
- Asystole, breath holding spells, cardiac pacing, children, quality of life,
- Publication type
- Journal Article MeSH
OBJECTIVES: To validate the physical and psychological effectiveness of cardiac pacing in pediatric patients with breath-holding spells (BHS) and prolonged asystole. MATERIALS AND METHODS: The records and clinical data of all the patients with BHS who presented to our center in the period of 2001-2013 were reviewed. All patients who received cardiac pacemaker implantation for prolonged asystole during BHS were included. In addition, the parents were asked to fill out a standardized quality of life (QOL) questionnaire. RESULTS: Seven patients were identified. The mean onset of symptoms was 7 month (1-12 months) of age, documented asystole was 12-21 seconds, and a permanent cardiac pacemaker device was implanted at a mean age of 23 months (8 months-3.9 years). No pacemaker related adverse events were recorded. Follow up showed immediate resolution from spells in four cases (4/7). Two patients (2/7) showed significant reduction of frequency and severity of spells, with complete elimination of loss of consciousness (LOC). One patient (1/7) with an additional neurologic disorder continued to have minor pallid BHS and eventually switched from pallid to cyanotic spells without further detection of bradycardia or asystole in holter examination. QOL questionnaire revealed significant reduction in subjective stress levels of patients (P = 0.012) and parents (P = 0.007) after pacemaker implantation. CONCLUSION: Cardiac pacing using appropriate pacemaker settings seems effective in the prevention of LOC and reduction of the frequency of BHS. Our results imply a reduction of subjective stress levels of patients and parents as well as an increased quality of everyday life. After all, randomized controlled trials of the influence of cardiac pacemaker implantation on subjective stress levels in patients with BHS are needed.
Children's Heart Centre University Hospital Motol 5 úvalu Prague Czech Republic
Department for Pediatric Cardiology University of Leipzig Heart Center Strümpellstr Leipzig Germany
Department of Neonatology University of Dresden Fetscherstraße Dresden Germany
See more in PubMed
Stephenson JB. Reflex anoxic seizures (“white breath-holding”): Non epileptic vagal attacks. Arch Dis Child. 1978;53:193–200. PubMed PMC
Kelly AM, Porter CJ, McGoon MD, Espinosa RE, Osborn MJ, Hayes DL. Breath holding spells associated with significant bradycardia: Succesful treatment with permanent pacemaker implantation. Pediatrics. 2001;108:698–702. PubMed
Benbadis S. The differential diagnosis of epilepsy: A critical review. Epilepsy Behav. 2009;15:15–21. PubMed
Blanc JJ, Corbel C, Mansourati J, Genet L. Evaluation of beta- adrenergic blockader therapy in vasovagal syncope reproduced by head-up tilt test. Arch Mal Coeur Vaiss. 1991;84:1453–7. PubMed
Breningstall GN. Breath-holding spells. Pediatr Neurol. 1996;14:91–7. PubMed
Cox MM, Perlman BA, Mayor MR, Silberstein TA, Levin E, Pringle L, et al. Acute and long- term beta-adrenergic blockade for patients with neurocardiogenic syncope. J Am Coll Cardiol. 1995;26:1293–8. PubMed
DiMario FJ., Jr Prospective Study of Children with Cyanotic and Pallid Breath-Holding Spells. Pediatrics. 2001;107:265–9. PubMed
DiMario FJ, Jr, Sarfarazi M. Family pedigree analysis of children with severe breath-holding spells. J Pediatr. 1997;130:647–51. PubMed
DiMario FJ, Jr, Bauer L, Baxter D. Respiratory sinus arrhythmia in children with severe cyanotic and pallid breath-holding spells. J Child Neurol. 1998;13:440–2. PubMed
DiMario FJ, Jr, Chee CM, Berman PH. Pallid breath-holding spells. Evaluation of the autonomic nervous system. Clin Pediatr (Phila) 1990;29:17–24. PubMed
Al Dhahri KN, Potts JE, Chiu CC, Hamilton RM, Sanatani S. Are implantable loop recorders useful in detecting arrhythmias in children with unexplained syncope? Pacing Clin Electrophysiol. 2009;32:1422–7. PubMed
Azam M, Bhatti N, Shahab N. Piracetam in severe breath-holding spells. Int J Psychiatry Med. 2008;38:195–201. PubMed
Kabra R, Gopinahannair R, Sandesara C, Messinger C, Olshansky B. The dual role of implantable loop recorder in patients with potentially arrhythmic symptoms: A retrospective single-center study. Pacing Clin Electrophysiol. 2009;32:908–12. PubMed
Di Pino A, Calabro MP, Gitto P, Bianca I, Oreto G. Permanent cardiac pacing for severe pallid breath-holding spells. Pacing Clin Electrophysiol. 2007;30:280–2. PubMed
McLeod KA, Wilson N, Hewitt J, Norrie J, Stephenson JB. Cardiac pacing for severe childhood neurally mediated syncope with reflex anoxic seizures. Heart. 1999;82:721–5. PubMed PMC
Kanjwal K, Karabin B, Kanjwal Y, Grubb BP. Differentiation of convulsive syncope from epilepsy with an implantable loop recorder. Int J Med Sci. 2009;6:296–300. PubMed PMC
Fejerman N. Nonepileptic disorders imitating generalized idiopathic epilepsies. Epilepsia. 2005;46:80–3. PubMed
Shore PM, Painter M. Adolescent asystolic syncope. J Child Neurol. 2002;17:395–7. PubMed
Villain E, Lucet V, Do Ngoc D, Bonnet D, Fraisse A, Kachaner J. Cardiac pacing in children with breath-holding spells. Arch Mal Coeur Vaiss. 2000;93:547–52. PubMed
Mattie-Luksic M, Javornisky G, DiMario FJ. Assessment of stress in mothers of children with severe breath-holding spells. Pediatrics. 2000;106:1–5. PubMed