One-Year Clinical and Computed Tomography Angiographic Outcomes After Bioresorbable Vascular Scaffold Implantation During Primary Percutaneous Coronary Intervention for ST-Segment-Elevation Myocardial Infarction: The PRAGUE-19 Study
Jazyk angličtina Země Spojené státy americké Médium print
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
26628591
DOI
10.1161/circinterventions.115.002933
PII: CIRCINTERVENTIONS.115.002933
Knihovny.cz E-zdroje
- Klíčová slova
- bioresorbable scaffold, computed tomography, myocardial infarction, restenosis, stent, stent thrombosis,
- MeSH
- infarkt myokardu diagnostické zobrazování terapie MeSH
- koronární angiografie * MeSH
- koronární angioplastika * MeSH
- lidé středního věku MeSH
- lidé MeSH
- počítačová rentgenová tomografie * MeSH
- prospektivní studie MeSH
- senioři MeSH
- tkáňové podpůrné struktury * MeSH
- vstřebatelné implantáty * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: Bioresorbable vascular scaffolds (BVS) represent promising new technology, but data on their long-term outcomes in ST-segment-elevation myocardial infarction (STEMI) setting are missing. The aim was to analyze 1-year clinical and computed tomographic angiographic outcomes after BVS implantation in STEMI. METHODS AND RESULTS: PRAGUE-19 is a prospective multicenter single-arm study enrolling consecutive STEMI patients undergoing primary percutaneous coronary intervention (pPCI) with intention-to-implant BVS. A total of 343 STEMI patients were screened during 15 months enrollment period, and 70 patients (mean age 58.6±10.3 and 74% males) fulfilled entry criteria and BVS was successfully implanted in 96% of them. All patients were invited for clinical and computed tomographic angiographic control 1 year after BVS implantation. Restenosis was defined as ≥75% area stenosis within the scaffolded segment. Three events were potentially related to BVS: 1 in-stent restenosis (treated 7 months after pPCI with drug-eluting balloon), 1 stent thrombosis (treated 2 weeks after pPCI by balloon dilatation-this patient stopped all medications after pPCI), and 1 sudden death at home 9 months after pPCI. Four other patients had events definitely unrelated to BVS. Overall, 1-year mortality was 2.9%. Computed tomographic angiography after 1 year was performed in 59 patients. All BVS were widely patent, and binary restenosis rate was 2% (the only restenosis mentioned above). Mean in-scaffold minimal luminal area was 7.8±2.6 mm(2), area stenosis was 20.1±16.3%, minimal luminal diameter was 3.0±0.6 mm, and diameter stenosis was 12.8±11.1%. CONCLUSIONS: BVS implantation in STEMI is feasible and safe and offers excellent 1-year clinical and angiographic outcomes.
Citace poskytuje Crossref.org