On-line automated evaluation of lipid nanoparticles transdermal permeation using Franz diffusion cell and low-pressure chromatography
Language English Country Netherlands Media print-electronic
Document type Journal Article, Research Support, Non-U.S. Gov't
PubMed
26695277
DOI
10.1016/j.talanta.2015.08.070
PII: S0039-9140(15)30290-3
Knihovny.cz E-resources
- Keywords
- Automated sampling, Franz diffusion cell, Low-pressure chromatography, Monolithic column, Nanoparticle permeation,
- MeSH
- Automation MeSH
- Chromatography, Reverse-Phase methods MeSH
- Diffusion MeSH
- Caffeine analysis chemistry MeSH
- Skin metabolism MeSH
- Humans MeSH
- Limit of Detection MeSH
- Lipids chemistry MeSH
- Nanoparticles chemistry MeSH
- Drug Carriers chemistry metabolism MeSH
- Permeability MeSH
- Swine MeSH
- Flow Injection Analysis MeSH
- Reproducibility of Results MeSH
- Pressure * MeSH
- Animals MeSH
- Check Tag
- Humans MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Names of Substances
- Caffeine MeSH
- Lipids MeSH
- Drug Carriers MeSH
A low-pressure liquid chromatography system for the on-line quantification of caffeine loaded into lipid nanoparticles that permeates pig skin was developed. The apparatus includes a Franz diffusion cell with computer-controlled sampling that allows collection of acceptor solution with automatic compensation for sample withdrawing, and a C-18 reversed-phase monolithic column integrated in a typical Flow Injection Analysis (FIA) set-up where separation between caffeine and other matrix elements is performed before spectrophotometric quantification at 273 nm. Several parameters regarding chromatographic analysis (propulsion element, column length, mobile phase composition, and flow rate) were studied along with the establishment of the sampling procedure. Under the selected conditions (monolithic column Chromolith® RP-18 15 mm × 4.6 mm i.d., acetonitrile:water 10:90 (v/v), flow rate 0.45 mL min(-1)) a detection limit of 4 μM and RSD values for caffeine concentration <2% were achieved. High recovery values were obtained when Hepes buffer incubated as acceptor solution in presence of pig skin for 8 h was spiked with caffeine (103±5%). The developed system also accounts for low organic solvent consumption, low operating costs, low generation of waste and high sample throughput (24 h(-1)). Due to the real time automated sampling and high throughput, transdermal permeation profiles of nanoformulations can be established within a time frame seldom observed by conventional techniques.
References provided by Crossref.org