High magnetic field test of bismuth Hall sensors for ITER steady state magnetic diagnostic
Status PubMed-not-MEDLINE Jazyk angličtina Země Spojené státy americké Médium print
Typ dokumentu časopisecké články
PubMed
27910548
DOI
10.1063/1.4964435
Knihovny.cz E-zdroje
- Publikační typ
- časopisecké články MeSH
Performance of bismuth Hall sensors developed for the ITER steady state magnetic diagnostic was investigated for high magnetic fields in the range ±7 T. Response of the sensors to the magnetic field was found to be nonlinear particularly within the range ±1 T. Significant contribution of the planar Hall effect to the sensors output voltage causing undesirable cross field sensitivity was identified. It was demonstrated that this effect can be minimized by the optimization of the sensor geometry and alignment with the magnetic field and by the application of "current-spinning technique."
Institute of Physics of the CAS Na Slovance 1992 2 182 21 Praha 8 Czech Republic
Institute of Plasma Physics of the CAS Za Slovankou 3 182 00 Praha 8 Czech Republic
ITER Organization Route de Vinon sur Verdon 13076 St Paul lez Durance France
Citace poskytuje Crossref.org
Ceramic-Chromium Hall Sensors for Environments with High Temperatures and Neutron Radiation