Note: On the choice of the appropriate excitation-pulse-length for assessment of slow luminescence decays
Status PubMed-not-MEDLINE Jazyk angličtina Země Spojené státy americké Médium print
Typ dokumentu časopisecké články
PubMed
28040916
DOI
10.1063/1.4971368
Knihovny.cz E-zdroje
- Publikační typ
- časopisecké články MeSH
The decay-time distribution deduced from luminescence kinetics experiments is, in general, dependent on the excitation pulse length as a direct consequence of different onset dynamics. We demonstrate this effect for the case of square excitation pulses applied to study the luminescence kinetics in Si nanocrystals. The short- and long-pulse limits are defined as 0.1 times the shortest lifetime in the distribution and 3 times the longest time, respectively. Outside these limits the decay-time distribution is independent on the pulse duration. In addition, we describe experimental conditions required to obtain a correct depiction of slow luminescence decay in the μs to ms time range.
Citace poskytuje Crossref.org
Changes of the absorption cross section of Si nanocrystals with temperature and distance