IGRA metody v rutinním provozu - QuantiFERON®-TB Gold nebo T-SPOT®.TB?
[IGRA methods in the routine operation - QuantiFERON®-TB Gold or T-SPOT.TB?]

. 2016 Fall ; 65 (4) : 246-248.

Jazyk čeština Země Česko Médium print

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid28078903
Odkazy

PubMed 28078903
PII: 60021

For indirect diagnosis of tuberculosis, two commercial IGRA (Interferon Gamma Release Assay) assays are available - primal QuantiFERON®-TB Gold test, new version QuantiFERON®-TB Gold Plus test (four tube, differentiation in activity CD4+ a CD8+) and T-SPOT®.TB test. Both methods are based on the same principle, but their workflows are different. In this article, both assays are compared on the collection of 284 patients. Inter-rate agreement measure showed 81.3% consistency and Cohens kappa index was calculated as 0.72. In case of discrepancy between IGRA and other methods (clinical aspects, X-ray diagnostic, etc.), results should be confirmed by second IGRA assay for correct interpretation.