BACKGROUND: In the international AIEOP-BFM ALL 2009 trial, asparaginase (ASE) activity was monitored after each dose of pegylated Escherichia coli ASE (PEG-ASE). Two methods were used: the aspartic acid β-hydroxamate (AHA) test and medac asparaginase activity test (MAAT). As the latter method overestimates PEG-ASE activity because it calibrates using E. coli ASE, method comparison was performed using samples from the AIEOP-BFM ALL 2009 trial. METHODS: PEG-ASE activities were determined using MAAT and AHA test in 2 sets of samples (first set: 630 samples and second set: 91 samples). Bland-Altman analysis was performed on ratios between MAAT and AHA tests. The mean difference between both methods, limits of agreement, and 95% confidence intervals were calculated and compared for all samples and samples grouped according to the calibration ranges of the MAAT and the AHA test. RESULTS: PEG-ASE activity determined using the MAAT was significantly higher than when determined using the AHA test (P < 0.001; Wilcoxon signed-rank test). Within the calibration range of the MAAT (30-600 U/L), PEG-ASE activities determined using the MAAT were on average 23% higher than PEG-ASE activities determined using the AHA test. This complies with the mean difference reported in the MAAT manual. With PEG-ASE activities >600 U/L, the discrepancies between MAAT and AHA test increased. Above the calibration range of the MAAT (>600 U/L) and the AHA test (>1000 U/L), a mean difference of 42% was determined. Because more than 70% of samples had PEG-ASE activities >600 U/L and required additional sample dilution, an overall mean difference of 37% was calculated for all samples (37% for the first and 34% for the second set). CONCLUSIONS: Comparison of the MAAT and AHA test for PEG-ASE activity confirmed a mean difference of 23% between MAAT and AHA test for PEG-ASE activities between 30 and 600 U/L. The discrepancy increased in samples with >600 U/L PEG-ASE activity, which will be especially relevant when evaluating high PEG-ASE activities in relation to toxicity, efficacy, and population pharmacokinetics.
Clinica Pediatrica Ospedale S Gerardo Università di Milano Bicocca Monza Italy
Department of Biochemistry and Oncology The Children's Hospital at Westmead
Department of Oncology and Onco Hematology University of Milan Milan Italy
Department of Paediatric Haematology and Oncology Hannover Medical School Hannover
Department of Pediatric Hematology and Oncology St Anna Children's Hospital
Department of Pediatric Hematology and Oncology University Children's Hospital of Muenster
Department of Pediatric Hematology and Oncology University Hospital Motol Praha Czech Republic
Department of Pediatrics and Adolescent Medicine Medical University Vienna Germany
Faculty of Pharmacy University of Sydney Sydney Australia
Institute of Biostatistics and Clinical Research University of Muenster Muenster Germany
Klinik für Allgemeine Pädiatrie Universitätsklinikum Schleswig Holstein Campus Kiel Kiel Germany
Pediatric Hematology Oncology Schneider Children's Medical Center Petah Tikva
Sackler Faculty of Medicine Tel Aviv University Tel Aviv Israel
Citace poskytuje Crossref.org