A Head-to-Head Analytical Comparison of Cobas 4800 HPV, PapilloCheck HPV Screening, and LMNX Genotyping Kit HPV GP for Detection of Human Papillomavirus DNA in Cervical and Cervicovaginal Swabs
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
PubMed
30165205
DOI
10.1016/j.jmoldx.2018.07.004
PII: S1525-1578(17)30496-8
Knihovny.cz E-zdroje
- MeSH
- DNA virů analýza genetika MeSH
- dospělí MeSH
- genotypizační techniky metody MeSH
- infekce papilomavirem diagnóza virologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- nádory děložního čípku virologie MeSH
- Papillomaviridae genetika MeSH
- reagenční diagnostické soupravy * MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- vagina virologie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Názvy látek
- DNA virů MeSH
- reagenční diagnostické soupravy * MeSH
High-risk human papillomavirus (hrHPV) infection is a cause of cervical cancer development. The addition of hrHPV testing to cervical cancer screening and monitoring of cervical intraepithelial neoplasia treatment improves the efficacy of screening and treatment, respectively. Self-sampling for hrHPV testing seems a promising tool for increasing patient participation in cervical cancer screening. In this project, 1198 cervical swabs obtained by physicians and 176 cervicovaginal swabs obtained by self-sampling (not collected in parallel) were analyzed for the presence of 14 hrHPV genotypes using three commercially available assays in comparison. HPV DNA was detected in 21.2% of all samples (21% of cervical swabs and 22.7% of cervicovaginal swabs). The cobas 4800 HPV Test was the most sensitive (0.983) and specific (0.992) for hrHPV detection overall. The PapilloCheck HPV-Screening and LMNX Genotyping Kit HPV GP had comparable specificity with that of the cobas (0.989 and 0.955, respectively), but lesser sensitivity (0.897 and 0.909, respectively). In physician-obtained cervical swabs, the cobas showed the highest sensitivity and specificity (0.980 and 0.994, respectively) for hrHPV detection, whereas in cervicovaginal swabs, the cobas had the highest sensitivity (1.00), but the PapilloCheck had the highest specificity (0.993). In conclusion, all of the detection methods evaluated were highly sensitive and specific for hrHPV detection from both clinician-collected cervical swabs and self-sampled cervicovaginal swabs.
Citace poskytuje Crossref.org
Impact of human papillomavirus infection on semen parameters and reproductive outcomes
Pitfalls of commercially available HPV tests in HPV68a detection