The matrix-assisted laser desorption/ionisation in-source decay of peptides using ion mobility enabled quadrupole-time-of-flight mass spectrometry
Jazyk angličtina Země Anglie, Velká Británie Médium print
Typ dokumentu hodnotící studie, časopisecké články
Grantová podpora
16-01639S
Czech Science Foundation
PubMed
30230090
DOI
10.1002/rcm.8284
Knihovny.cz E-zdroje
- MeSH
- hmotnostní spektrometrie přístrojové vybavení metody MeSH
- hmyz MeSH
- hormon uvolňující prolaktin chemie MeSH
- kationické antimikrobiální peptidy chemie MeSH
- lidé MeSH
- peptidy chemie MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice metody MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- Názvy látek
- hormon uvolňující prolaktin MeSH
- kationické antimikrobiální peptidy MeSH
- peptidy MeSH
RATIONALE: In-source decay (ISD) matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry with a 1,5-diaminonaphthalene (1,5-DAN) matrix is used for the structural characterisation of peptides. However, MALDI spectra are intrinsically complicated by the presence of matrix ions, which interfere with the peptide fragments. This may cause false-positive results or reduced sequence coverage. This paper reports investigations of ISD processes in an intermediate pressure MALDI ion source and a protocol for the removal of interfering ions using ion mobility separation (IMS). METHODS: An intermediate pressure MALDI source of a Q-IMS-Q-TOF instrument (Synapt G2) has been employed for the ISD of selected peptides using a 1,5-DAN matrix. RESULTS: Successful coupling of the MALDI source tuned for ISD experiments using IMS is demonstrated. The IMS made it possible to remove interfering matrix ions effectively from the spectra and thus to increase the confidence of spectral interpretation. Extensive fragment series corresponding to N-Cα bond cleavages were observed under optimised conditions; on the other hand, weaker series of ions caused by peptide bond cleavages were prevalent for default conditions and/or the α-hydroxycinnamic acid matrix. CONCLUSIONS: Ion mobility has been used for the elimination of matrix ions. The technique has been applied to top-down sequencing of non-tryptic peptides, such as the human palmitoylated analogue of prolactin-releasing peptide used in recent obesity studies, and human and insect antimicrobial peptides.
Citace poskytuje Crossref.org
Peptide Analysis by Soft X-ray Atmospheric Pressure Photoionization Mass Spectrometry