Radiobiological quantities in proton-therapy: Estimation and validation using Geant4-based Monte Carlo simulations

. 2019 Feb ; 58 () : 72-80. [epub] 20190205

Jazyk angličtina Země Itálie Médium print-electronic

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid30824153
Odkazy

PubMed 30824153
DOI 10.1016/j.ejmp.2019.01.018
PII: S1120-1797(19)30018-3
Knihovny.cz E-zdroje

PURPOSE: The Geant4 Monte Carlo simulation toolkit was used to reproduce radiobiological parameters measured by irradiating three different cancerous cell lines with monochromatic and clinical proton beams. METHODS: The experimental set-up adopted for irradiations was fully simulated with a dedicated open-source Geant4 application. Cells survival fractions was calculated coupling the Geant4 simulations with two analytical radiobiological models: one based on the LEM (Local Effect Model) approach and the other on a semi-empirical parameterisation. Results was evaluated and compared with experimental data. RESULTS AND CONCLUSIONS: The results demonstrated the Geant4 ability to reproduce radiobiological quantities for different cell lines.