Reliability of a measurement technique for achilles tendon length

. 2019 Oct ; 37 (20) : 2389-2395. [epub] 20190625

Language English Country Great Britain, England Media print-electronic

Document type Journal Article, Validation Study

Recently, there has been an increasing amount of literature dealing with new methods of Achilles tendon (AT) length measurement. However, most of these studies measured the AT length between the calcaneus and medial head of the gastrocnemius and the reliability of such a measurement has not been satisfactorily presented. The purpose of this study was to determine the reliability of the measurement of AT length within and between sessions. AT length was measured by using a combination of ultrasound imaging and optoelectronic stereophotogrammetry. Nineteen healthy athletes visited the lab on six different days where the AT length was measured on both lower extremities: 1) from the calcaneus to the mid-point of the medial and lateral heads of the gastrocnemius; and 2) from the calcaneus to the soleus musculotendinous attachment. The reliability results indicated high intraclass correlation coefficients (ICC > 0.8), a low typical error (< 0.6) and a standard error of measurement (SEM < 5.5 mm) for all measured AT lengths on within and between sessions. This non-invasive reliable measurement method may be recommended for sport science research purposes.