Dental implants are often made of titanium alloys. Implant therapy currently promises a good long-term result without impacting health; however, its success depends on many factors. In this article, the authors focus on the most common risk factors associated with metallic surgical implants. Titanium-induced hypersensitivity can lead to symptoms of implant rejection. Corrosion and biofilm formation are additional situations in which these symptoms may occur. For medical purposes, it is important to define and discuss the characteristics of metals used in implantable devices and to ensure their biocompatibility. To avoid hypersensitivity reactions to metallic dental implants, precautionary principles for primary prevention should be established.

Zobrazit více v PubMed

Gaviria L., Salcido J. P., Guda T., Ong J. L. Current trends in dental implants. Journal of the Korean Association of Oral and Maxillofacial Surgeons. 2014;40(2):50–60. doi: 10.5125/jkaoms.2014.40.2.50. PubMed DOI PMC

Hemmings K., Griffiths B., Hobkirk J., Scully C. Improving occlusion and orofacial aesthetics: tooth repair and replacement. British Medical Journal. 2000;321(7258):438–441. doi: 10.1136/bmj.321.7258.438. PubMed DOI PMC

Sun Z., Herring S. W., Tee B. C., Gales J. Alveolar ridge reduction after tooth extraction in adolescents: an animal study. Archives of Oral Biolog. 2013;58(7):813–825. doi: 10.1016/j.archoralbio.2012.12.013. PubMed DOI PMC

Chen S., Buser D. ITI Treatment Guide, Volume 3, Implant Placement in Post-Extraction Sites-Treatment Options. Berlin, Germany: Quintessenz; 2008.

Quirynen M., van Assche N., Botticelli D., Berglundh T. How does the timing of implant placement to extraction affect outcome? The International Journal of Oral & Maxillofacial Implants. 2007;23(1, article no 56) PubMed

Tomlin E. M., Nelson S. J., Rossmann J. A. Ridge preservation for implant therapy: a review of the literature. The Open Dentistry Journal. 2014;8(1):66–76. doi: 10.2174/1874210601408010066. PubMed DOI PMC

Fraunhofer J. A. Dental Materials at a Glance. 2nd. Oxford, UK: Wiley Blackwell; 2013.

Longo G., Ioannidu C. A., Scotto d’Abusco A., et al. Improving osteoblast response in vitro by a nanostructured thin film with titanium carbide and titanium oxides clustered around graphitic carbon. Public Library of Science one. 2016;11(3) doi: 10.1371/journal.pone.0152566.e0152566 PubMed DOI PMC

Goutam M., Giriyapura C., Mishra S., Gupta S. Titanium allergy: a literature review. Indian Journal of Dermatology. 2014;59(6):p. 630. doi: 10.4103/0019-5154.143526. PubMed DOI PMC

Gittens R., Olivares-Navarrete R., Tannenbaum R., Boyan B., Schwartz Z. Electrical implications of corrosion for osseointegration of titanium implants. Journal of Dental Research. 2011;90(12):1389–1397. doi: 10.1177/0022034511408428. PubMed DOI PMC

Barbieri M., Mencio F., Papi P., et al. Corrosion behavior of dental implants immersed into human saliva: preliminary results of an in vitro study. European Review for Medical and Pharmacological Sciences. 2017;21(16):3543–3548. PubMed

Delgado-Ruiz R., Romanos G. Potential causes of titanium particle and ion release in implant dentistry: a systematic review. International Journal of Molecular Sciences. 2018;19(11):3585–3548. doi: 10.3390/ijms19113585. PubMed DOI PMC

Phillips P. L., Wolcott R. D., Fletcher J., Schultz G. S. Biofilms made easy. Wounds International. 2011;1(3):1–6.

Chen M., Yu Q., Sun H. Novel strategies for the prevention and treatment of biofilm related infections. International Journal of Molecular Sciences. 2013;14(9):18488–18501. doi: 10.3390/ijms140918488. PubMed DOI PMC

Ramasamy Mohankandhasamy, Lee Jintae. Recent nanotechnology approaches for prevention and treatment of biofilm-associated infections on medical devices. BioMed Research International. 2016;2016:17. doi: 10.1155/2016/1851242.1851242 PubMed DOI PMC

Rendueles O., Ghigo J.-M. Multi-species biofilms: how to avoid unfriendly neighbors. FEMS Microbiology Reviews. 2012;36(5):972–989. doi: 10.1111/j.1574-6976.2012.00328.x. PubMed DOI

Whitchurch C. B., Tolker-Nielsen T., Ragas P. C., Mattick J. S. Extracellular DNA required for bacterial biofilm formation. Science. 2002;295(5559, article no 1487) doi: 10.1126/science.295.5559.1487. PubMed DOI

Mah T. F., O'Toole G. A. Mechanisms of biofilm resistance to antimicrobial agents. Trends in Microbiology. 2001;9(1):34–39. doi: 10.1016/S0966-842X(00)01913-2. PubMed DOI

Lewis K. Persister cells and the riddle of biofilm survival. Biochemistry. 2005;70(2):267–274. doi: 10.1007/s10541-005-0111-6. PubMed DOI

Manson J. D., Eley B. M. Outline of Periodontics. 4th. London, UK: Wright; 2000.

Zimmerli W. Clinical presentation and treatment of orthopaedic implant‐associated infection. Journal of Internal Medicine. 2014;276(2):111–119. doi: 10.1111/joim.12233. PubMed DOI

Sandhu P., Gindri I., Siddiqui D., Rodrigues D. Dicationic imidazolium-based ionic liquid coatings on zirconia surfaces: physico-chemical and biological characterization. Journal of Functional Biomaterials. 2017;8(4, article no 50) doi: 10.3390/jfb8040050. PubMed DOI PMC

Pachauri P., Bathala L. R., Sangur R. Techniques for dental implant nanosurface modifications. The Journal of Advanced Prosthodontics. 2014;6(6):498–504. doi: 10.4047/jap.2014.6.6.498. PubMed DOI PMC

Fage S. W., Muris J., Jakobsen S. S., Thyssen J. P. Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity. Contact Dermatitis. 2016;74(6):323–345. doi: 10.1111/cod.12565. PubMed DOI

Wood M. M., Warshaw E. M. Hypersensitivity reactions to titanium: diagnosis and management. Dermatitis. 2015;26(1):7–25. PubMed

Gladwin M., Bagby M. Clinical Aspects of Dental Materials; Theory. Practice and Cases. 3rd. Baltimore, Md, USA: LWW; 2009.

Teo Z. W. W., Schalock P. C. Metal hypersensitivity reactions to implanted devices-facts and fictions. Journal of Investigational Allergology and Clinical Immunology. 2016;26(5):279–294. doi: 10.18176/jiaci.0095. PubMed DOI

Mak T. W., Saunders M. E. The Immune Response, Basic and Clinical Principles. Burlington, NJ, USA: Elsevier Academic Press; 2006.

Stejskal V., Stejskal J., terzl I., Hudecek R., Šterzl I., Hudeček R. Diagnosis and treatment of metal-induced side-effects. Neuroendocrinology Letters. 2006;28(5):7–16. PubMed

Chaturvedi T. Allergy related to dental implant and its clinical signifikance. Clinical, Cosmetic And Investigational Dentistry. 2013;5:57–61. doi: 10.2147/CCIDE.S35170. PubMed DOI PMC

Prochazkova J., Sterzl I., Kucerova H., Bartova J., Stejskal V. D. M. The beneficial effect of amalgam replacement on health in patients with autoimmunity. Neuroendocrinology Letters. 2004;25(3):211–218. PubMed

Hallab N. J., Mikecz K., Vermes C., Skipor A., Jacobs J. J. Differential lymphocyte reactivity to serum-derived metal-protein complexes produced from cobalt-based and titanium-based implant alloy degradation. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2001;56(3):427–436. doi: 10.1002/1097-4636(20010905)56:3<427::AID-JBM1112>3.0.CO;2-E. doi: 10.1002/1097-4636(20010905)56:3<427::AID-JBM1112>3.3.CO;2-5. PubMed DOI

Valentine-Thon E., Müller K., Guzzi G., Kreisel S., Ohnsorge P., Sandkamp M. LTT-MELISA® is clinically relevant for detecting and monitoring metal sensitivity. Neuroendocrinology Letters. 2006;28(5):17–24. PubMed

Wood M. M., Warshaw E. M. Hypersensitivity reactions to titanium: diagnosis and management. Dermatitis. 2015;26(1):7–25. doi: 10.1097/DER.0000000000000091. PubMed DOI

Oliva X., Oliva J., Oliva J. D. Full-mouth oral rehabilitation in a titanium allergy patient using zirconium oxide dental implants and zirconium oxide restorations. a case report from an ongoing clinical study. The European Journal of Esthetic Dentistry. 2010;5(2):190–203. PubMed

Nawaz F., Wall B. M. Drug rash with eosinophilia and systemic symptoms (DRESS) syndrome: suspected association with titanium bioprosthesis. The American Journal of the Medical Sciences. 2007;334(3):215–218. doi: 10.1097/MAJ.0b013e318141f723. PubMed DOI

du Prrez L. A., Butow K. W., Swart T. J. Implant failure due to titanium hypersensitivity/allergy? report of a case. Journal of the South African Dental Association. 2007;62(1):24–25. PubMed

Nejnovějších 20 citací...

Zobrazit více v
Medvik | PubMed

Titanium and Other Metal Hypersensitivity Diagnosed by MELISA® Test: Follow-Up Study