Investigation of chromatographic peak broadening in supercritical fluid chromatography/atmospheric pressure chemical ionization mass spectrometry
Status PubMed-not-MEDLINE Jazyk angličtina Země Německo Médium print-electronic
Typ dokumentu časopisecké články
Grantová podpora
CZ.02.1.01/0.0/0.0/16_019/0000754
The Ministry of Education, Youth, and Sports of the Czech Republic
PubMed
31849194
DOI
10.1002/jssc.201901130
Knihovny.cz E-zdroje
- Klíčová slova
- multimode ionization source, peak tailing, supercritical fluid chromatography, volatile compounds,
- Publikační typ
- časopisecké články MeSH
Multimode ionization source allows for switching between different ionization techniques, for example, electrospray and atmospheric pressure chemical ionization, within a single analysis. Supercritical fluid chromatography can handle a wide polarity range of substances from hydrophilic to lipophilic in a single run and can undoubtedly benefit from versatility of this ion source. Nevertheless, we observed a significant chromatographic peak broadening effect in atmospheric pressure chemical ionization mode during supercritical fluid chromatography-mass spectrometry analysis of volatile flavor compounds with a dual ion source named ESCi (Waters). Surprisingly, this effect was not related to the separation process but was triggered solely by the ion source conditions. Neither of photodiode array detector, electrospray mode nor a dedicated atmospheric pressure chemical ionization source suffered from such a phenomenon. Chromatographic peak profiles of ten test substances obtained with the dual ion source were compared with photodiode array detector data as a reference. The broadening effect was more pronounced for volatile compounds with low polarity. Dependence of peak broadening on the ion source settings was systematically investigated. Tuning of desolvation gas flow and its temperature dramatically reduced peak distortion and increased detection sensitivity.
Zobrazit více v PubMed
Gallagher, R. T., Balogh, M. P., Davey, P., Jackson, M. R., Sinclair, I., Southern, L. J., Combined electrospray ionization−atmospheric pressure chemical ionization source for use in high-throughput LC−MS applications. Anal. Chem. 2003, 75, 973-977.
Pilařová, V., Plachká, K., Khalikova, M. A., Svec, F., Nováková, L., Recent developments in supercritical fluid chromatography - mass spectrometry: Is it a viable option for analysis of complex samples? TrAC 2019, 112, 212-225.
Lesellier, E., West, C., The many faces of packed column supercritical fluid chromatography - a critical review. J. Chromatogr. A 2015, 1382, 2-46.
Bernal, J. L., Martín, M. T., Toribio, L., Supercritical fluid chromatography in food analysis. J. Chromatogr. A 2013, 1313, 24-36.
Tyśkiewicz, K., Dębczak, A., Gieysztor, R., Szymczak, T., Rój, E., Determination of fat- and water-soluble vitamins by supercritical fluid chromatography: A review. J. Sep. Sci. 2018, 41, 336-350.
Donato, P., Inferrera, V., Sciarrone, D., Mondello, L., Supercritical fluid chromatography for lipid analysis in foodstuffs. J. Sep. Sci. 2017, 40, 361-382.
Laboureur, L., Ollero, M., Touboul, D., Lipidomics by supercritical fluid chromatography. Int. J. Mol. Sci. 2015, 16, 13868-13884.
Jones, M. D., Rainville, P. D., Isaac, G., Wilson, I. D., Smith, N. W., Plumb, R. S., Ultra high resolution SFC-MS as a high throughput platform for metabolic phenotyping: Application to metabolic profiling of rat and dog bile. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 2014, 966, 200-207.
Jumaah, F., Larsson, S., Essén, S., Cunico, L. P., Holm, C., Turner, C., Sandahl, M., A rapid method for the separation of vitamin D and its metabolites by ultra-high performance supercritical fluid chromatography-mass spectrometry. J. Chromatogr. A 2016, 1440, 191-200.
Lemasson, E., Bertin, S., West, C., Use and practice of achiral and chiral supercritical fluid chromatography in pharmaceutical analysis and purification. J. Sep. Sci. 2016, 39, 212-233.
Abbott, E., Veenstra, T. D., Issaq, H. J., Clinical and pharmaceutical applications of packed-column supercritical fluid chromatography. J. Sep. Sci. 2008, 31, 1223-1230.
Liang, Y., Zhou, T., Recent advances of online coupling of sample preparation techniques with ultra high performance liquid chromatography and supercritical fluid chromatography. J. Sep. Sci. 2019, 42, 226-242.
Taguchi, K., Fukusaki, E., Bamba, T., Simultaneous analysis for water- and fat-soluble vitamins by a novel single chromatography technique unifying supercritical fluid chromatography and liquid chromatography. J. Chromatogr. A 2014, 1362, 270-277.
Ishibashi, M., Izumi, Y., Sakai, M., Ando, T., Fukusaki, E., Bamba, T., High-throughput simultaneous analysis of pesticides by supercritical fluid chromatography coupled with high-resolution mass spectrometry. J. Agric. Food Chem. 2015, 63, 4457-4463.
Herniman, J. M., Langley, G. J., Open Access UHPSFC/MS - an additional analytical resource for an academic mass spectrometry facility. Rapid Commun. Mass Spectrom. 2016, 30, 1811-1817.
Schaffrath, M., Weidmann, V., Maison, W., Enantioselective high performance liquid chromatography and supercritical fluid chromatography separation of spirocyclic terpenoid flavor compounds. J. Chromatogr. A 2014, 1363, 270-277.
Xie, J., Cheng, J., Han, H., Sun, B., Yanik, G. W., Resolution of racemic γ-lactone flavors on Chiralpak AD by packed column supercritical fluid chromatography. Food Chem. 2011, 124, 1107-1112.