Distance-based paper device using polydiacetylene liposome as a chromogenic substance for rapid and in-field analysis of quaternary ammonium compounds

. 2020 May ; 412 (13) : 3221-3230. [epub] 20200402

Status PubMed-not-MEDLINE Language English Country Germany Media print-electronic

Document type Journal Article

Grant support
Grant no. PHD/0177/2558 Thailand Research Fund through the Royal Golden Jubilee Ph.D. Program, the Higher Education Commission and Mahidol University
19-02108S Czech Science Foundation

Links

PubMed 32242258
DOI 10.1007/s00216-020-02583-y
PII: 10.1007/s00216-020-02583-y
Knihovny.cz E-resources

This work presents an affordable distance-based microfluidic paper-based device (μPAD), using polydiacetylene (PDA) liposome as a chromogenic substance with a smartphone-based photo editor, for rapid and in-field analysis of quaternary ammonium compounds (QACs) (e.g., didecyldimethylammonium chloride (DDAC), benzyldimethyltetradecyl ammonium chloride (BAC), and cetylpyridinium chloride (CPC)). In-field analysis of these compounds is important to ensure their antimicrobial activity and user safety since they are widely utilized as disinfectants in households and hospitals. The μPAD featured a thermometer-like shape consisting of a sample reservoir and a microchannel as the detection zone, which was pre-deposited with PDA liposome. The color change from blue to red appeared in the presence of QACs and the color bar lengths were proportional to the QAC concentrations. Reactions of QACs with the PDA required a specific pH range (from pH 4.0 to 10.0) and a readout time of 7 min. Analytical performance characteristics of the device were tested with DDAC, BAC, and CPC showing acceptable specificity, accuracy (96.1-109.4%), and precision (%RSDs ≤ 9.3%). Limits of detection and quantitation were in the ranges of 20 to 80 and 70 to 250 μM, respectively. Feasibility of the newly developed device was demonstrated for in-field analysis of QACs in fumigation solution providing comparable results with those obtained from a colorimetric assay (P > 0.05). The proposed device shows potentials for further applications of other analytes since it offers speed, simplicity, and affordability for in-field analysis, especially in remote areas where expertise, resources, and infrastructures are limited. Graphical abstract.

References provided by Crossref.org

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...