In Vivo Measurements of Middle Ear Temperature During Transcanal Endoscopic Ear Surgery

. 2021 Sep 01 ; 42 (8) : e1037-e1041.

Jazyk angličtina Země Spojené státy americké Médium print

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/pmid33741819
Odkazy

PubMed 33741819
DOI 10.1097/mao.0000000000003142
PII: 00129492-202109000-00022
Knihovny.cz E-zdroje

OBJECTIVE: The light emitted from the endoscope during transcanal endoscopic ear surgery (TEES) heats the intratympanic space. This heat may potentially be dangerous to nearby important structures, as documented by in vitro and by animal and cadaveric studies. The aim of our work was to monitor middle ear temperatures during TEES in vivo. STUDY DESIGN: Cohort study. SETTING: Tertiary referral hospital. PATIENTS: Four patients (15-69 yrs old) underwent transcanal endoscopic tympanoplasties for chronic perforation or retraction. INTERVENTION: After elevating the tympanomeatal flap, a thermocouple was placed in the middle ear to measure the heat generated by a 30° Hopkins rod telescope (11 cm long, 2.7 mm wide) and fiberoptic light emitting diode light source. MAIN OUTCOME MEASURES: Middle ear temperature in the retrotympanum was monitored under these conditions: at 50 and 100% light intensity, after removing and wiping the endoscope tip, during suctioning and following middle ear irrigation. RESULTS: Maximum middle ear temperature ranged from 36.26-37.30°C. Pulling out and wiping the endoscope caused no change or minimal decrease of 0.16°C. Middle ear irrigation caused a temperature drop of 2.05°C to 5.11°C. Suctioning was associated with a drop from 0.24°C to 3.91°C that was dependent on the depth of the endoscopic tip. CONCLUSION: Middle ear temperatures during TEES using a Hopkins rod telescope and light-emitting diode light source reach values corresponding to physiological body temperature, and do not reach dangerous levels.

Zobrazit více v PubMed

Latuska RF, Carlson ML, Neff BA, et al. Auricular burns associated with operating microscope use during otologic surgery. Otol Neurotol 2014; 35:227–233.

Salzman R, Bakaj T, Herman J, et al. Endoscopic ear surgery—review. Otorinolaryng a Foniat 2016; 65:184–187.

Drescher DG. Noise-induced reduction of inner-ear microphonic response: Dependence on body temperature. Science 1974; 185:273–274.

Rossmann C, Garrett-Mayer E, Rattay F, et al. Dynamics of tissue shrinkage during ablative temperature exposures. Physiol Meas 2014; 35:55–67.

Ozturan O, Dogan R, Eren SB, et al. Intraoperative thermal safety of endoscopic ear surgery utilizing a holder. Am J Otolaryngol 2018; 39:585–591.

Tomazic PV, Hammer GP, Gerstenberger C, et al. Heat development at nasal endoscopes’ tips: Danger of tissue damage? A laboratory study. Laryngoscope 2012; 122:1670–1673.

MacKeith SAC, Frampton S, Pothier DD. Thermal properties of operative endoscopes used in otorhinolaryngology. J Laryngol Otol 2008; 122:711–714.

Kozin ED, Lehmann A, Carter M, et al. Thermal effects of endoscopy in a human temporal bone model: Implications for endoscopic ear surgery. Laryngoscope 2014; 124:332–339.

Aksoy F, Dogan R, Ozturan O, et al. Thermal effects of cold light sources used in otologic surgery. Eur Arch Otorhinolaryngol 2015; 272:2679–2687.

Bottrill I, Perrault DF, Poe D. In vitro and in vivo determination of the thermal effect of middle ear endoscopy. Laryngoscope 1996; 106:213–216.

Yavuz Y, Skogås JG, Güllüoğlu MG, et al. Are cold light sources really cold? Surg Laparosc Endosc Percutaneous Tech 2006; 16:370–376.

Prasad N, Tavaluc R, Harley E. Thermal injury to common operating room materials by fiber optic light sources and endoscopes. Am J Otolaryngol 2019; 40:631–635.

Terzi S, Dursun E, Özgür A, et al. Can use of a cold light source in endoscopic middle ear surgery cause sensorineural hearing loss? Indian J Otol 2016; 22:213–216.

Ito T, Kubota T, Takagi A, et al. Safety of heat generated by endoscope light sources in simulated transcanal endoscopic ear surgery. Auris Nasus Larynx 2016; 43:501–506.

Salzman R, Stárek I, Heřman J. Multiple cerebral venous thrombosis after endoscopic stapedotomy: A potential role of endoscope-produced heat. Acta Otolaryngologica Case Rep 2017; 2:21–25.

Mitchell S, Coulson C. Endoscopic ear surgery: A hot topic? J Laryngol Otol 2017; 131:117–122.

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...