Sensitivity of secondary electrospray ionization mass spectrometry to a range of volatile organic compounds: Ligand switching ion chemistry and the influence of Zspray™ guiding electric fields

. 2021 Nov 30 ; 35 (22) : e9187.

Status PubMed-not-MEDLINE Jazyk angličtina Země Velká Británie, Anglie Médium print

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid34473872

Grantová podpora
18-12902S Grantová Agentura České Republiky

RATIONALE: Secondary electrospray ionization (SESI) is currently only semi-quantitative. In the Zspray™ arrangement of SESI-MS, the transfer of ions from near atmospheric pressure to a triple quadrupole is achieved by guiding electric fields that partially desolvate both reagent and analyte ions which must be understood. Also, to make SESI-MS more quantitative, the mechanisms and the kinetics of the reaction processes, especially ligand switching reactions of hydrated hydronium reagent ions, H3 O+ (H2 O)n , with volatile organic compound (VOC) molecules, need to be understood. METHODS: A modified Zspray™ ESI ion source operating at sub-atmospheric pressure with analyte sample gas introduced via an inlet coaxial with the spray was used. Variation of the ion-guiding electric fields was used to reveal the degree of desolvation of both reagent and analyte ions. The instrument sensitivity was determined for several classes of VOCs by introducing bag samples of suitably varying concentrations as quantified on-line using selected ion flow tube MS. RESULTS: Electric field desolvation resulted in largely protonated VOCs, MH+ , and their monohydrates, MH+ H2 O, and for some VOCs proton-bound dimer ions, MH+ M, were formed. There was a highly linear response of the ion signal to the measured VOC sample concentration, which provided the instrument sensitivities, S, for 25 VOCs. The startling results show very wide variations in S from near 0 to 1 for hydrocarbons, and up to 100, on a relative scale, for polar compounds such as monoketones and unsaturated aldehydes. CONCLUSIONS: The complex ion chemistry occurring in the SESI ion source, largely involving gas-phase ligand switching, results in widely variable sensitivities for different classes of VOCs. The sensitivity is observed to depend on the dipole moment and proton affinity of the analyte VOC molecule, M, and to decrease with the observed fraction of MH+ H2 O, but other yet unrecognized factors must play a significant role.

Zobrazit více v PubMed

Wu C, Siems WF, Hill HH. Secondary electrospray ionization ion mobility spectrometry/mass spectrometry of illicit drugs. Anal Chem. 2000;72(2):396-403.

Bruderer T, Gaisl T, Gaugg MT, et al. On-line analysis of exhaled breath. Chem Rev. 2019;119(19):10803-10828.

Rioseras AT, Singh KD, Nowak N, et al. Real-time monitoring of tricarboxylic acid metabolites in exhaled breath. Anal Chem. 2018;90(11):6453-6460.

Bregy L, Muggler AR, Martinez-Lozano Sinues P, et al. Differentiation of oral bacteria in in vitro cultures and human saliva by secondary electrospray ionization-mass spectrometry. Sci Rep. 2015;5(1):15163.

Bregy L, Nussbaumer-Ochsner Y, Martinez-Lozano Sinues P, et al. Real-time mass spectrometric identification of metabolites characteristic of chronic obstructive pulmonary disease in exhaled breath. Clin Mass Spectrom. 2018;7:29-35.

Lan J, Parte FB, Vidal-de-Miguel G, Zenobi R. Secondary electrospray ionization. In: Beauchamp J, Davis C, Pleil J, eds. Breathborne Biomarkers and the Human Volatilome. 2nd ed. Boston, MA: Elsevier; 2020:185-199.

Rioseras AT, Gaugg MT, Martinez-Lozano Sinues P. Secondary electrospray ionization proceeds via gas-phase chemical ionization. Anal Methods. 2017;9(34):5052-5057.

Ahadi E, Konermann L. Ejection of solvated ions from electrosprayed methanol/water nanodroplets studied by molecular dynamics simulations. J Am Chem Soc. 2011;133(24):9354-9363.

Rankin-Turner S, Heaney LM. Applications of ambient ionization mass spectrometry in 2020: An annual review. Anal Sci Adv. 2021;2(3-4):193-212.

Martínez-Lozano P, Rus J, de la Mora GF, Hernández M, de la Mora JF. Secondary electrospray ionization (SESI) of ambient vapors for explosive detection at concentrations below parts per trillion. J Am Soc Mass Spectrom. 2009;20(2):287-294.

Lee JHJ, Zhu JJ. Optimizing secondary electrospray ionization high-resolution mass spectrometry (SESI-HRMS) for the analysis of volatile fatty acids from gut microbiome. Metabolites. 2020;10(9):351.

Liu C, Zeng J, Sinues P, Fang M, Zhou Z, Li X. Quantification of volatile organic compounds by secondary electrospray ionization-high resolution mass spectrometry. Anal Chim Acta. 2021;1180:338876.

Nguyen S, Fenn JB. Gas-phase ions of solute species from charged droplets of solutions. Proc Natl Acad Sci. 2007;104(4):1111-1117.

Martínez-Lozano Sinues P, Fernandez de la Mora J. Direct analysis of fatty acid vapors in breath by electrospray ionization and atmospheric pressure ionization-mass spectrometry. Anal Chem. 2008;80(21):8210-8215.

Fernandez de la Mora J. Ionization of vapor molecules by an electrospray cloud. Int J Mass Spectrom. 2011;300(2):182-193.

Martinez-Lozano Sinues P, Criado E, Vidal G. Mechanistic study on the ionization of trace gases by an electrospray plume. Int J Mass Spectrom. 2012;313:21-29.

Aernecke MJ, Mendum T, Geurtsen G, Ostrinskaya A, Kunz RR. Vapor pressure of hexamethylene triperoxide diamine (HMTD) estimated using secondary electrospray ionization mass spectrometry. J Phys Chem A. 2015;119(47):11514-11522.

Dryahina K, Som S, Smith D, Španěl P. Reagent and analyte ion hydrates in secondary electrospray ionization mass spectrometry (SESI-MS), their equilibrium distributions and dehydration in an ion transfer capillary: Modelling and experiments. Rapid Commun Mass Spectrom. 2021;35(7):e9047.

Stahnke H, Kittlaus S, Kempe G, Hemmerling C, Alder L. The influence of electrospray ion source design on matrix effects. J Mass Spectrom. 2012;47(7):875-884.

Barrios-Collado C, Vidal-de-Miguel G, Martinez-Lozano Sinues P. Numerical modeling and experimental validation of a universal secondary electrospray ionization source for mass spectrometric gas analysis in real-time. Sens Actuators B. 2016;223:217-225.

Španěl P, Smith D. Advances in on-line absolute trace gas analysis by SIFT-MS. Curr Anal Chem. 2013;9(4):525-539.

Smith D, Španěl P. The SIFT and FALP techniques; applications to ionic and electronic reactions studies and their evolution to the SIFT-MS and FA-MS analytical methods. Int J Mass Spectrom. 2015;377:467-478.

Španěl P, Smith D. Progress in SIFT-MS: Breath analysis and other applications. Mass Spectrom Rev. 2011;30(2):236-267.

Španěl P, Smith D. Quantification of volatile metabolites in exhaled breath by selected ion flow tube mass spectrometry, SIFT-MS. Clin Mass Spectrom. 2020;16:18-24.

IUPAC. Compendium of Chemical Terminology (the "Gold Book"). 2nd ed. Compiled by A. D. McNaught and A. Wilkinson. Oxford: Blackwell Scientific Publications; 1997.

Hiraoka K. Fundamentals of Mass Spectrometry. New York: Springer; 2013.

Španěl P, Smith D. Influence of weakly bound adduct ions on breath trace gas analysis by selected ion flow tube mass spectrometry (SIFT-MS). Int J Mass Spectrom. 2009;280(1-3):128-135.

Španěl P, Smith D. Reactions of hydrated hydronium ions and hydrated hydroxide ions, with some hydrocarbons and oxygen-bearing organic-molecules. J Phys Chem. 1995;99(42):15551-15556.

Španěl P, Smith D. SIFT studies of the reactions of H3O+, NO+ and O2+ with a series of alcohols. Int J Mass Spectrom. 1997;167:375-388.

Španěl P, Ji YF, Smith D. SIFT studies of the reactions of H3O+, NO+ and O2+ with a series of aldehydes and ketones. Int J Mass Spectrom. 1997;165:25-37.

Smith D, Španěl P, Dryahina K. H3O+, NO+ and O2+ reactions with saturated and unsaturated monoketones and diones; focus on hydration of product ions. Int J Mass Spectrom. 2019;435:173-180.

Španěl P, Smith D. SIFT studies of the reactions of H3O+, NO+ and O2+ with a series of volatile carboxylic acids and esters. Int J Mass Spectrom. 1998;172(1-2):137-147.

Schoon N, Amelynck C, Vereecken L, Arijs E. A selected ion flow tube study of the reactions of H3O+, NO+ and O2+ with a series of monoterpenes. Int J Mass Spectrom. 2003;229(3):231-240.

Wang TS, Španěl P, Smith D. Selected ion flow tube, SIFT, studies of the reactions of H3O+, NO+ and O2+ with eleven C10H16 monoterpenes. Int J Mass Spectrom. 2003;228(1):117-126.

Smith SC, McEwan MJ, Giles K, Smith D, Adams NG. Unimolecular decomposition of a polyatomic ion in a variable-temperature selected-ion-flow-drift tube: Experiment and theoretical interpretation. Int J Mass Spectrom Ion Process. 1990;96(1):77-96.

Španěl P, Smith D. Influence of water vapour on selected ion flow tube mass spectrometric analyses of trace gases in humid air and breath. Rapid Commun Mass Spectrom. 2000;14(20):1898-1906.

Lias SG, Levin RD, Kafafi SA. Ion energetics data. In: NIST Chemistry WebBook, NIST Standard Reference Database Number 69. Gaithersburg, MD: National Institute of Standards and Technology; 2016.

Neese F. Software update: The ORCA program system, version 4.0. Wiley Interdiscip Rev Comput Mol Sci. 2018;8(1):e1327.

Haynes WM (Ed). CRC Handbook of Chemistry and Physics. 94th ed. Boca Raton, FL: CRC Press; 2013.

Španěl P, Zabka J, Zymak I, Smith D. Selected ion flow tube study of the reactions of H3O+ and NO+ with a series of primary alcohols in the presence of water vapour in support of selected ion flow tube mass spectrometry. Rapid Commun Mass Spectrom. 2017;31(5):437-446.

Smith D, Chippendale TWE, Španěl P. Reactions of the selected ion flow tube mass spectrometry reagent ions H3O+ and NO+ with a series of volatile aldehydes of biogenic significance. Rapid Commun Mass Spectrom. 2014;28(17):1917-1928.

Španěl P, Van Doren JM, Smith D. A selected ion flow tube study of the reactions of H3O+, NO+, and O2+ with saturated and unsaturated aldehydes and subsequent hydration of the product ions. Int J Mass Spectrom. 2002;213(2-3):163-176.

Smith D, Chippendale TWE, Dryahina K, Španěl P. SIFT-MS analysis of nose-exhaled breath; mouth contamination and the influence of exercise. Curr Anal Chem. 2013;9(4):565-575.

King J, Mochalski P, Unterkofler K, et al. Breath isoprene: Muscle dystrophy patients support the concept of a pool of isoprene in the periphery of the human body. Biochem Biophys Res Commun. 2012;423(3):526-530.

Dryahina K, Španěl P, Pospisilova V, et al. Quantification of pentane in exhaled breath, a potential biomarker of bowel disease, using selected ion flow tube mass spectrometry. Rapid Commun Mass Spectrom. 2013;27(17):1983-1992.

Španěl P, Smith D. Selected ion flow tube-mass spectrometry: Detection and real-time monitoring of flavours released by food products. Rapid Commun Mass Spectrom. 1999;13(7):585-596.

Smith D, Španěl P. The novel selected-ion flow tube approach to trace gas analysis of air and breath. Rapid Commun Mass Spectrom. 1996;10(10):1183-1198.

Španěl P, Smith D. Selected ion flow tube studies of the reactions of H3O+, NO+, and O2+ with several aromatic and aliphatic hydrocarbons. Int J Mass Spectrom. 1998;181(1-3):1-10.

Dillon LA, Stone VN, Croasdell LA, Fielden PR, Goddard NJ, Paul Thomas CL. Optimisation of secondary electrospray ionisation (SESI) for the trace determination of gas-phase volatile organic compounds. Analyst. 2010;135(2):306-314.

Smith D, Španěl P. Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis. Mass Spectrom Rev. 2005;24(5):661-700.

Spesyvyi A, Lacko M, Dryahina K, Smith D, Španěl P. Ligand switching ion chemistry: An SIFDT case study of the primary and secondary reactions of protonated acetic acid hydrates with acetone. J Am Soc Mass Spectrom. 2021;32(8):2251-2260.

Spesyvyi A, Smith D, Španěl P. Selected ion flow-drift tube mass spectrometry: Quantification of volatile compounds in air and breath. Anal Chem. 2015;87(24):12151-12160.

Nejnovějších 20 citací...

Zobrazit více v
Medvik | PubMed

Ion Chemistry in Dielectric Barrier Discharge Ionization: Recent Advances in Direct Gas Phase Analyses

. 2026 Mar-Apr ; 45 (2) : 193-217. [epub] 20241106

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...