Unattended automated office blood pressure measurement in children
Language English Country Great Britain, England Media print-electronic
Document type Journal Article
- Keywords
- Unattended automated office blood pressure, children, masked hypertension, white-coat hypertension,
- MeSH
- Blood Pressure Monitoring, Ambulatory MeSH
- Child MeSH
- Hypertension * diagnosis MeSH
- Blood Pressure MeSH
- Humans MeSH
- Blood Pressure Determination MeSH
- Child, Preschool MeSH
- White Coat Hypertension * diagnosis MeSH
- Check Tag
- Child MeSH
- Humans MeSH
- Child, Preschool MeSH
- Publication type
- Journal Article MeSH
PURPOSE: We studied the performance of unattended automated office blood pressure (uAOBP) measurement in children, in relation to oscillometric office BP (OBP) and ambulatory blood pressure monitoring (ABPM). MATERIALS AND METHODS: One hundred and eleven stable treated and untreated outpatients investigated for hypertension underwent uAOBP measurements (seated unattended in a quiet room separate from the renal clinic room, six times after a 5 min rest with the BpTRU device), and immediately before using the oscillometric device. Ambulatory 24 h blood pressure monitoring (ABPM) was performed on the same day in a subgroup of 42 children. RESULTS: UAOBP measurements were successful in 106 children (95%), 5 pre-school children did not tolerate to be alone in the room. The mean ± SD systolic/diastolic uAOBP, OBP and daytime ABP were 109.1 ± 14.0/70.8 ± 10.7 mmHg, 121.6 ± 16.5/77.6 ± 10.5 mmHg and 123.5 ± 11.3/73.7 ± 6.8 mmHg, respectively. Systolic/diastolic uAOBP was significantly lower than OBP by 13.6/7.6 mmHg (p < 0.0001) and lower than daytime ABP by 14.4 ± 0.5/2.9 ± 0.3 mmHg (p < 0.0001). The heart rate was not significantly different during uAOBP than during OBP measurements. On Bland Altman analysis the uAOBP underestimated OBP by a mean of 15.6 mmHg for systolic BP and by 8.6 mmHg for diastolic BP. In all 9 children with white-coat systolic hypertension uAOBP was within the normal range (<95th pc for OBP), in six of nine children with white-coat diastolic hypertension uAOBP was within the normal range however, in three of them it was elevated despite normal ABP. CONCLUSION: uAOBP measurement is feasible in school-aged children, its values are considerably lower than OBP as well as daytime ABP and it could help with detection of white-coat systolic hypertension. The clinical applicability of uAOBP in children should be confirmed in further studies.
2nd Faculty of Medicine Univerzita Karlova Praha Czech Republic
Department of Internal Medicine 2 Univerzita Karlova Praha Czech Republic
Department of Pediatrics Charles University Prague 2nd Faculty of Medicine Prague Czech Republic
References provided by Crossref.org