Clinical outcomes and survival comparison between NexGen all-poly and its metal-backed equivalent in total knee arthroplasty

. 2023 Sep ; 47 (9) : 2207-2213. [epub] 20230418

Jazyk angličtina Země Německo Médium print-electronic

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/pmid37069277
Odkazy

PubMed 37069277
PubMed Central PMC10439055
DOI 10.1007/s00264-023-05772-3
PII: 10.1007/s00264-023-05772-3
Knihovny.cz E-zdroje

PURPOSE: This study aims to compare total knee replacement (TKA) with NexGen All-Poly (APT) and NexGen Metal-Backed (MBT) in terms of implant survivorship, reasons leading to implant failure and functional results of defined age categories. METHODS: A single-centre, retrospective evaluation of 812 patients who underwent knee replacement with NexGen CR between 2005 and 2021, comparing a modern congruent APT component to a modular MBT equivalent component using a similar surgical technique at a notable mean follow-up duration. Implant survival, functional outcomes using the Knee Society Score and range of motion were evaluated and compared in different age categories. RESULTS: Of the 812 NexGen CR TKAs performed at our institution, 410 (50.4%) used APT components and 402 (49.6%) MBT components. The survival rate of NexGen APT was 97.1% and that of NexGen MBT was 93.2% (p = 0.36). Removal of the implant occurred overall in 15 cases, for MBT in ten cases, and for APT in four cases. The FS was proved to be significantly higher when APT components were implanted in younger patients than for MBT (p = 0.005). A similar range of motion between the components was recorded (p = 0.1926). CONCLUSION: Under defined conditions, we measured the clinical results of implants from a single manufacturer implanted in a single department using a similar surgical technique. Considering the limitations, we suggest that all-polyethylene tibial components are equal or even superior to metal-backed ones across the examined age categories.

Zobrazit více v PubMed

Gudnason A, Hailer NP, W-Dahl A, , et al. All-polyethylene versus metal-backed tibial components—an analysis of 27,733 cruciate-retaining total knee replacements from the Swedish Knee Arthroplasty Register. J Bone Joint Surg. 2014;96:994–999. doi: 10.2106/JBJS.M.00373. PubMed DOI

Gustke KA, Gelbke MK. All-polyethylene tibial component use for elderly, low-demand total knee arthroplasty patients. J Arthroplasty. 2017;32:2421–2426. doi: 10.1016/j.arth.2017.02.077. PubMed DOI

Longo UG, Ciuffreda M, D’Andrea V, et al. All-polyethylene versus metal-backed tibial component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2017;25:3620–3636. doi: 10.1007/s00167-016-4168-0. PubMed DOI

Passias PG, Bono OJ, Bono JV. Total knee arthroplasty in patients of advanced age: a look at outcomes and complications. J Knee Surg. 2020;33:001–007. doi: 10.1055/s-0038-1676067. PubMed DOI

Apostolopoulos V, Tomáš T, Boháč P, et al. Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method. Comput Methods Programs Biomed. 2022;220:106834. doi: 10.1016/j.cmpb.2022.106834. PubMed DOI

Kahlenberg CA, Lyman S, Joseph AD et al (2019) Comparison of patient-reported outcomes based on implant brand in total knee arthroplasty: a prospective cohort study. Bone Joint J 101-B:48–54. 10.1302/0301-620X.101B7.BJJ-2018-1382.R1 PubMed

de Steiger RN, Muratoglu O, Lorimer M, et al. Lower prosthesis-specific 10-year revision rate with crosslinked than with non-crosslinked polyethylene in primary total knee arthroplasty. Acta Orthop. 2015;86:721–727. doi: 10.3109/17453674.2015.1065046. PubMed DOI PMC

Hasan S, Marang-Van De Mheen PJ, Kaptein BL, et al. All-polyethylene versus metal-backed posterior stabilized total knee arthroplasty: similar 2-year results of a randomized radiostereometric analysis study. Acta Orthop. 2019;90:590–595. doi: 10.1080/17453674.2019.1668602. PubMed DOI PMC

Kurtz SM, Ong KL, Lau E, et al. International survey of primary and revision total knee replacement. Int Orthop (SICOT) 2011;35:1783–1789. doi: 10.1007/s00264-011-1235-5. PubMed DOI PMC

Robertsson O, Lidgren L, Sundberg M, W-Dahl A (2020) The Swedish Knee Arthroplasty Register - Annual report 2020, Sweden, Media-Tryck, Lund

Sabeh K, Alam M, Rosas S, et al. Cost analysis of all-polyethylene compared to metal-backed implants in total knee arthroplasty. Surg Technol Int. 2018;32:249–255. PubMed

Ryan SP, Steele JR, Plate JF et al (2021) All-polyethylene tibia: an opportunity for value-based care in bundled reimbursement initiatives. Orthopedics 44:e114–e118. 10.3928/01477447-20201009-01 PubMed

Mohan V, Inacio MCS, Namba RS, et al. Monoblock all-polyethylene tibial components have a lower risk of early revision than metal-backed modular components: a registry study of 27,657 primary total knee arthroplasties. Acta Orthop. 2013;84:530–536. doi: 10.3109/17453674.2013.862459. PubMed DOI PMC

Selvan DR, Santini AJA, Davidson JS, Pope JA. The medium-term survival analysis of an all-polyethylene tibia in a single-series cohort of over 1000 knees. J Arthroplasty. 2020;35:2837–2842. doi: 10.1016/j.arth.2020.05.017. PubMed DOI

Herschmiller T, Bradley KE, Wellman SS, Attarian DE. Early to midterm clinical and radiographic survivorship of the all-polyethylene versus modular metal-backed tibia component in primary total knee replacement. J Surg Orthop Adv. 2019;28:108–114. PubMed

Gioe TJ, Maheshwari AV. The all-polyethylene tibial component in primary total knee arthroplasty. J Bone Joint Surg. 2010;92:478–487. doi: 10.2106/JBJS.I.00842. PubMed DOI

Yassin M, Garti A, Weissbrot M, et al. All-polyethylene tibial components are not inferior to metal-backed tibial components in long-term follow-up of knee arthroplasties. Eur J Orthop Surg Traumatol. 2015;25:1087–1091. doi: 10.1007/s00590-015-1645-y. PubMed DOI

Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12 PubMed

Loures FB, Correia W, Reis JH, et al. Outcomes after knee arthroplasty in extra-articular deformity. Int Orthop (SICOT) 2019;43:2065–2070. doi: 10.1007/s00264-018-4147-9. PubMed DOI

Pinsornsak P, Kanitnate S, Boontanapibul K. The effect of immediate post-operative knee range of motion photographs on post-operative range of motion after total knee arthroplasty: an assessor-blinded randomized controlled clinical trial in sixty patients. Int Orthop (SICOT) 2021;45:101–107. doi: 10.1007/s00264-020-04877-3. PubMed DOI

Houdek MT, Wagner ER, Wyles CC, et al. All-polyethylene tibial components: an analysis of long-term outcomes and infection. J Arthroplasty. 2016;31:1476–1482. doi: 10.1016/j.arth.2015.12.048. PubMed DOI

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...