The Gastroscopy RAte of Cleanliness Evaluation (GRACE) Scale: an international reliability and validation study
Jazyk angličtina Země Německo Médium print-electronic
Typ dokumentu časopisecké články, multicentrická studie, validační studie
PubMed
39321961
DOI
10.1055/a-2422-0856
Knihovny.cz E-zdroje
- MeSH
- dospělí MeSH
- ezofágus diagnostické zobrazování MeSH
- gastroskopie * normy MeSH
- lidé středního věku MeSH
- lidé MeSH
- odchylka pozorovatele MeSH
- průřezové studie MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- žaludek diagnostické zobrazování MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- validační studie MeSH
BACKGROUND: Mucosal visualization during upper gastrointestinal (UGI) endoscopy can be impaired by the presence of foam, bubbles, and mucus. Some UGI endoscopy visibility scales have been proposed but have not undergone multicenter validation. This study aimed to develop and validate the Gastroscopy RAte of Cleanliness Evaluation (GRACE) scale. METHODS: A multicenter, international, cross-sectional study was conducted. The GRACE scale is based on a score from 0 (worst) to 3 (excellent) for esophagus, stomach, and duodenum, for a total ranging from 0 to 9. In phase 1, four expert endoscopists evaluated 60 images twice, with a 2-week interval between rounds; in phase 2, the same 60 images were scored twice by one expert and one nonexpert endoscopist from 27 endoscopy departments worldwide. For reproducibility assessment and real-time validation, the scale was applied to consecutive patients undergoing gastroscopy at each center. RESULTS: On internal validation, interobserver agreement was 0.81 (95 %CI 0.73-0.87) and 0.80 (95 %CI 0.72-0.86), with reliability of 0.73 (95 %CI 0.63-0.82) and 0.72 (95 %CI 0.63-0.81), in the two rounds, respectively. On external validation, overall interobserver agreement was 0.85 (95 %CI 0.82-0.88) and reliability was 0.79 (95 %CI 0.73-0.84). In real-time evaluation, the overall proportion of correct classifications was 0.80 (95 %CI 0.77-0.82). CONCLUSIONS: The GRACE scale showed good interobserver agreement, reliability, and validity. The widespread use of this scale could enhance quality and standardize the assessment of mucosal cleanliness during UGI endoscopy, pushing endoscopists to strive for excellent visibility and reducing the risk of missed lesions.
Citace poskytuje Crossref.org