Simultaneous determination of phenylalanine and tyrosine levels in human blood obtained by the dried spot technique for monitoring of patients with phenylketonuria
Language English Country Great Britain, England Media print-electronic
Document type Journal Article
PubMed
40120298
DOI
10.1016/j.jpba.2025.116831
PII: S0731-7085(25)00172-4
Knihovny.cz E-resources
- Keywords
- Dried blood spot, Liquid chromatography with mass spectrometry and fluorescence detection, Parameters affecting quantitative results, Phenylalanine, Tyrosine,
- MeSH
- Phenylalanine * blood MeSH
- Phenylketonurias * blood diagnosis MeSH
- Humans MeSH
- Limit of Detection MeSH
- Reproducibility of Results MeSH
- Tandem Mass Spectrometry methods MeSH
- Dried Blood Spot Testing * methods MeSH
- Tyrosine * blood MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Names of Substances
- Phenylalanine * MeSH
- Tyrosine * MeSH
Monitoring patients with phenylketonuria (PKU) requires accurately measuring phenylalanine and tyrosine levels in a small volume of blood samples obtained by the dried blood spot (DBS) technique. The aim was to study selected parameters influencing the quantitative results. Phenylalanine and tyrosine were extracted from DBS samples with methanol, and 5 internal standard introduction techniques were tested. Phenylalanine and tyrosine levels were measured in 6-mm discs punched from DBS, pre-punched 9-mm discs containing the entire DBS sample, and liquid blood by HPLC-MS-MS. Levels in 6-mm discs punched from DBS measured by HPLC-MS/MS were compared with those measured by the HPLC-FLD. The analytical parameters of the method are satisfactory, linearity in the range of 25-1200 μmol/L (LOD, LOQ and LLOQ values 0.2 μmol/L, 0.5 μmol/L and 3.8 μmol/L for phenylalanine, 0.5 μmol/L, 1.5 μmol/L and 5.1 μmol/L for tyrosine), within-run precision 1.8 %-3.7 % for phenylalanine, 1.9 %-2.7 % for tyrosine, between-run precision 4.7 %-5.9 % for phenylalanine, 4.1 %-5.4 % for tyrosine, recovery 93.8 %-100.4 % for phenylalanine and 93.7 %-99.1 % for tyrosine. Good agreement was found between phenylalanine and tyrosine concentrations in 6-mm discs punched from DBS (R = 0.896, p < 0.001, and R = 0.907, p < 0.001, respectively), pre-punched 9-mm discs containing the entire DBS sample (R = 0.960, p < 0.001, and R = 0.950, p < 0.001, respectively) and liquid blood, as well as between phenylalanine and tyrosine concentrations obtained by HPLC-MS/MS and HPLC-FLD (R = 0.968, p < 0.001, and R = 0.984, p < 0.001, respectively). The presented method is suitable for monitoring patients with PKU.