PURPOSE: Evaluate whether optic disc edema results in changes in retinal microcirculation. PATIENTS AND METHODS: The study group consisted of 11 patients with unilateral optic disc edema (papilledema). The control group consisted of the healthy eyes of the same 11 patients. Patients underwent non-invasive photo-spectrometric retinal oximetry using Oxymap T1 retinal oximeter (Oxymap, Reykjavik, Iceland). In the eyes of these 11 patients, we examined the diameter of the retinal arteries and veins, arterial and venous blood oxygen saturation, and the difference in oxygen saturation between arterioles and venules (A-V difference). RESULTS: In the papilledema group, the decrease in the retinal arterial diameter was statistically significant (p=0.001). The median diameter of the retinal artery was 11.70 px (IQR 1.47) or after conversion 109.00 µm (IQR 14.00) in the papilledema group and 13.75 px (IQR 1.61) or 128.00 µm (IQR 15.00) in the control group. The increase in the diameter of the retinal veins in the papilledema group was statistically significant (p=0.012), where the median diameter in the papilledema group was 20.88 px (IQR 3.72) or 194.00 µm (IQR 35.00), and in the control group was 18.18 px (IQR 3.60) or 169 µm (IQR 33.00). There was a statistically significant decrease (p<0.001) in the venous saturation in the papilledema group with a median value of 53.16% (IQR 17.38) and 60.02% (IQR 11.98) in the control group. The median of the A-V difference was 51.92 (IQR 15.96) in the papilledema group, resp. 38.49 (IQR 9.75) in the control group and a significant increase in the papilledema group (p<0.001) was reported. CONCLUSION: Automatic retinal oximetry demonstrated changes in the retinal microcirculation in patients with optic disc edema.

Zobrazit více v PubMed

Diblík P. Neurooftalmologie. In: Heissigerová J, editor.

Rambousek J, Preiningerová Lízrová J, Česká M B, Hložánek M. Otoky terčů zrakového nervu - společné téma oftalmologů a neurologů. DOI

Hübnerová P, Mlčák P, Šínová I, Karhanová M, Šín M. Current use of automatic retinal oximetry – a review. PubMed DOI

Stefansson E, Olafsdottir OB, Einarsdottir AB, et al. Retinal oximetry discovers novel biomarkers in retinal and brain diseases. PubMed DOI

Geirsdottir A, Palsson O, Hardarson SH, Olafsdottir OB, Kristjansdottir JV, Stefánsson E. Retinal vessel oxygen saturation in healthy individuals. PubMed DOI

Blondal R, Sturludottir MK, Hardarson SH, Halldorsson GH, Stefansson E. Reliability of vessel diameter measurements with a retinal oximeter. PubMed DOI

Guduru A, Martz TG, Waters A, Kshirsagar AV, Garg S. Oxygen saturation of retinal vessels in all stages of diabetic retinopathy and correlation to ultra-wide field fluorescein angiography. PubMed DOI

Hardarson SH, Stefansson E. Retinal oxygen saturation is altered in diabetic retinopathy. PubMed DOI

Hardarson SH, Basit S, Jonsdottir TE, et al. Oxygen saturation in human retinal vessels is higher in dark than in light. PubMed DOI

Rilven S, Torp TL, Grauslund J. Retinal oximetry in patients with ischaemic retinal diseases. PubMed DOI

Khoobehi B, Firn K, Thompson H, Reinoso M, Beach J. Retinal arterial and venous oxygen saturation is altered in diabetic patients. PubMed DOI

Zhang W, Li L, Zou D, et al. Retinal vessel oxygen saturation in patients with unilateral carotid artery stenosis: a pilot study. PubMed DOI

Goharian I, Iverson SM, Ruiz RC, Kishor K, Greenfield DS, Sehi M. Reproducibility of retinal oxygen saturation in normal and treated glaucomatous eyes. PubMed DOI

Traustason S, Jensen AS, Arvidsson HS, Munch IC, Sondergaard L, Larsen M. Retinal oxygen saturation in patients with systemic hypoxemia. PubMed DOI

Alnawaiseh M, Ertmer C, Seidel L, et al. Feasibility of optical coherence tomography angiography to assess changes in retinal microcirculation in ovine haemorrhagic shock. PubMed DOI PMC

Tani T, Nagaoka T, Nakabayashi S, Yoshioka T, Yoshida A. Autoregulation of retinal blood flow in response to decreased ocular perfusion pressure in cats: comparison of the effects of increased intraocular pressure and systemic hypotension. PubMed DOI

Wang L, Cull GA, Fortune B. Optic nerve head blood flow response to reduced ocular perfusion pressure by alteration of either the blood pressure of intraocular pressure. PubMed DOI PMC

Vandawalle E, Pinto LA, Olafsdottir OB, et al. Oximetry in glaucoma: correlation of metabolic change with structural and functional damage. PubMed DOI

Šín M, Chrapek O, Karhanová M, et al. The effect of pars plana vitrectomy and nuclear cataract on oxygen saturation in retinal vessels, diabetic and non-diabetic patients compared. PubMed DOI

Šínová I, Řehák J, Nekolová J, et al. Correlation between ischemic index of retinal vein occlusion an oxygen saturation in retinal vessels. PubMed DOI

Williamson TH, Harris A. Color Doppler ultrasound imaging of the eye and orbit. PubMed DOI

Eliasdottir TS, Bragason D, Hardarson SH, Kristjansdottir G, Stefansson E. Venous oxygen saturation is reduced and variable in central retinal vein occlusion. PubMed DOI

Shahidi M, Felder AE, Tan O, Blair NP, Huang D. Retinal oxygen delivery and metabolism in healthy and sickle cell retinopathy subjects. PubMed DOI PMC

Svrčinová T, Mareš J, Chrapek O, et al. Changes in oxygen saturation and the retinal nerve fibre layer in patients with optic neuritis - a pilot study. PubMed DOI

Belamkar AV, Jabbehdari S, Harris A, Hajrasouliha AR. Clinical implications of retinal oximetry in retinal vein occlusion: a review. PubMed DOI PMC

Hardarson SH. Retinal oximetry. PubMed DOI

Hardarson SH, Stefansson E. Oxygen saturation in central retinal vein occlusion. PubMed DOI

Yoneya S, Saito T, Nishiyama Y, et al. Retinal oxygen saturation levels in patients with central retinal vein occlusion. PubMed DOI

Mohan A, Dabir S, Kurian M, Shetty R, Chidambara L, Kumar RS. Perivascular and quadrant nerve fiber layer thickness and its relationship with oxygen saturation. PubMed DOI

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...