• This record comes from PubMed

Optimizing R-wave visualization in left bundle branch area pacing: The role of lower intercostal space V1 placements

. 2025 Jul ; 11 (7) : 707-709. [epub] 20250422

Status PubMed-not-MEDLINE Language English Country United States Media electronic-ecollection

Document type Journal Article

Links

PubMed 40951647
PubMed Central PMC12432853
DOI 10.1016/j.hrcr.2025.04.013
PII: S2214-0271(25)00115-0
Knihovny.cz E-resources

See more in PubMed

Vijayaraman P., Sharma P.S., Cano Ó., et al. Comparison of left bundle branch area pacing and biventricular pacing in candidates for resynchronization therapy. J Am Coll Cardiol. 2023;82:228–241. PubMed

Burri H., Vijayaraman P. A new era of physiologic cardiac pacing. Eur Heart J Suppl. 2023;25(suppl G):G1–G3. PubMed PMC

Curila K., Jurak P., Jastrzebski M., et al. Left bundle branch pacing compared to left ventricular septal myocardial pacing increases interventricular dyssynchrony but accelerates left ventricular lateral wall depolarization. Heart Rhythm. 2021;18:1281–1289. PubMed

Abobaker A., Rana R.M. V1 and V2 pericordial leads misplacement and its negative impact on ECG interpretation and clinical care. Ann Noninvasive Electrocardiol. 2021;26 PubMed PMC

Meiburg R., Rijks J.H., Beela A.S., et al. Comparison of novel ventricular pacing strategies using an electro-mechanical simulation platform. Europace. 2023;25 PubMed PMC

Walsh B. Misplacing V1 and V2 can have clinical consequences. Am J Emerg Med. 2018;36:865–870. PubMed

Burri H., Jastrzebski M., Cano Ó., et al. EHRA clinical consensus statement on conduction system pacing implantation: endorsed by the Asia Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS), and Latin American Heart Rhythm Society (LAHRS) Europace. 2023;25:1208–1236. PubMed PMC