Since 2010, EURADOS Working Group 9 (Radiation Dosimetry in Radiotherapy) has been involved in the investigation of secondary and scattered radiation doses in X-ray and proton therapy, especially in the case of pediatric patients. The main goal of this paper is to analyze and compare out-of-field neutron and non-neutron organ doses inside 5- and 10-year-old pediatric anthropomorphic phantoms for the treatment of a 5-cm-diameter brain tumor. Proton irradiations were carried out at the Cyclotron Centre Bronowice in IFJ PAN Krakow Poland using a pencil beam scanning technique (PBS) at a gantry with a dedicated scanning nozzle (IBA Proton Therapy System, Proteus 235). Thermoluminescent and radiophotoluminescent dosimeters were used for non-neutron dose measurements while secondary neutrons were measured with track-etched detectors. Out-of-field doses measured using intensity-modulated proton therapy (IMPT) were compared with previous measurements performed within a WG9 for three different photon radiotherapy techniques: 1) intensity-modulated radiation therapy (IMRT), 2) three-dimensional conformal radiation therapy (3D CDRT) performed on a Varian Clinac 2300 linear accelerator (LINAC) in the Centre of Oncology, Krakow, Poland, and 3) Gamma Knife surgery performed on the Leksell Gamma Knife (GK) at the University Hospital Centre Zagreb, Croatia. Phantoms and detectors used in experiments as well as the target location were the same for both photon and proton modalities. The total organ dose equivalent expressed as the sum of neutron and non-neutron components in IMPT was found to be significantly lower (two to three orders of magnitude) in comparison with the different photon radiotherapy techniques for the same delivered tumor dose. For IMPT, neutron doses are lower than non-neutron doses close to the target but become larger than non-neutron doses further away from the target. Results of WG9 studies have provided out-of-field dose levels required for an extensive set of radiotherapy techniques, including proton therapy, and involving a complete description of organ doses of pediatric patients. Such studies are needed for validating mathematical models and Monte Carlo simulation tools for out-of-field dosimetry which is essential for dedicated epidemiological studies which evaluate the risk of second cancers and other late effects for pediatric patients treated with radiotherapy.
- Publikační typ
- časopisecké články MeSH
PURPOSE: Treatment-related toxicity after irradiation of brain tumours has been underreported in the literature. Furthermore, there is considerable heterogeneity on how and when toxicity is evaluated. The aim of this European Particle Network (EPTN) collaborative project is to develop recommendations for uniform follow-up and toxicity scoring of adult brain tumour patients treated with radiotherapy. METHODS: A Delphi method-based consensus was reached among 24 international radiation-oncology experts in the field of neuro-oncology concerning the toxicity endpoints, evaluation methods and time points. RESULTS: In this paper, we present a basic framework for consistent toxicity scoring and follow-up, using multiple levels of recommendation. Level I includes all recommendations that are considered minimum of care, whereas level II and III are optional evaluations in the advanced clinical or research setting, respectively. Per outcome domain, the clinical endpoints and evaluation methods per level are listed. Where relevant, the organ at risk threshold doses for recommended referral to specific organ specialists are defined. CONCLUSION: These consensus-based recommendations for follow-up will enable the collection of uniform toxicity data of brain tumour patients treated with radiotherapy. With adoptation of this standard, collaboration will be facilitated and we can further propel the research field of radiation-induced toxicities relevant for these patients. An online tool to implement this guideline in clinical practice is provided at www.cancerdata.org.
- MeSH
- dospělí MeSH
- konsensus MeSH
- lidé MeSH
- mozek MeSH
- nádory baze lební * radioterapie MeSH
- následné studie MeSH
- protonová terapie * škodlivé účinky MeSH
- protony MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Since 2012, the European Radiation Dosimetry Group (EURADOS) has developed its Strategic Research Agenda (SRA), which contributes to the identification of future research needs in radiation dosimetry in Europe. Continued scientific developments in this field necessitate regular updates and, consequently, this paper summarises the latest revision of the SRA, with input regarding the state of the art and vision for the future contributed by EURADOS Working Groups and through a stakeholder workshop. Five visions define key issues in dosimetry research that are considered important over at least the next decade. They include scientific objectives and developments in (i) updated fundamental dose concepts and quantities, (ii) improved radiation risk estimates deduced from epidemiological cohorts, (iii) efficient dose assessment for radiological emergencies, (iv) integrated personalised dosimetry in medical applications and (v) improved radiation protection of workers and the public. This SRA will be used as a guideline for future activities of EURADOS Working Groups but can also be used as guidance for research in radiation dosimetry by the wider community. It will also be used as input for a general European research roadmap for radiation protection, following similar previous contributions to the European Joint Programme for the Integration of Radiation Protection Research, under the Horizon 2020 programme (CONCERT). The full version of the SRA is available as a EURADOS report (www.eurados.org).
- MeSH
- dávka záření MeSH
- ionizující záření MeSH
- lidé MeSH
- monitorování radiace * MeSH
- radiační ochrana * MeSH
- radiometrie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND AND PURPOSE: To update the digital online atlas for organs at risk (OARs) delineation in neuro-oncology based on high-quality computed tomography (CT) and magnetic resonance (MR) imaging with new OARs. MATERIALS AND METHODS: In this planned update of the neurological contouring atlas published in 2018, ten new clinically relevant OARs were included, after thorough discussion between experienced neuro-radiation oncologists (RTOs) representing 30 European radiotherapy-oncology institutes. Inclusion was based on daily practice and research requirements. Consensus was reached for the delineation after critical review. Contouring was performed on registered CT with intravenous (IV) contrast (soft tissue & bone window setting) and 3 Tesla (T) MRI (T1 with gadolinium & T2 FLAIR) images of one patient (1 mm slices). For illustration purposes, delineation on a 7 T MRI without IV contrast from a healthy volunteer was added. OARs were delineated by three experienced RTOs and a neuroradiologist based on the relevant literature. RESULTS: The presented update of the neurological contouring atlas was reviewed and approved by 28 experts in the field. The atlas is available online and includes in total 25 OARs relevant to neuro-oncology, contoured on CT and MRI T1 and FLAIR (3 T & 7 T). Three-dimensional (3D) rendered films are also available online. CONCLUSION: In order to further decrease inter- and intra-observer OAR delineation variability in the field of neuro-oncology, we propose the use of this contouring atlas in photon and particle therapy, in clinical practice and in the research setting. The updated atlas is freely available on www.cancerdata.org.
PURPOSE: To facilitate the initiation of observational studies on late effects of proton therapy in pediatric patients, we report on current patterns of proton therapy use worldwide in patients aged less than 22 years. MATERIALS & METHODS: Fifty-four proton centers treating pediatric patients in 2016 in 11 countries were invited to respond to a survey about the number of patients treated during that year by age group, intent of treatment, delivery technique and tumor types. RESULTS: Among the 40 participating centers (participation rate: 74%), a total of 1,860 patients were treated in 2016 (North America: 1205, Europe: 432, Asia: 223). The numbers of patients per center ranged from 1 to 206 (median: 29). Twenty-four percent of the patients were <5 years of age, and 50% <10 years. More than 30 pediatric tumor types were identified, mainly treated with curative intent: 48% were CNS, 25% extra-cranial sarcomas, 7% neuroblastoma, and 5% hematopoietic tumors. About half of the patients were treated with pencil beam scanning. Treatment patterns were broadly similar across the three continents. CONCLUSION: To our knowledge, this survey provides the first worldwide assessment of proton therapy use for pediatric cancer management. Since previous estimates in the United States and Europe, CNS tumors remain the cancer types most commonly treated with protons in 2016. However, the proportion of extra-cranial tumors is growing worldwide. The typically low numbers of patients treated in each center indicate the need for international research collaborations to assess long-term outcomes of proton therapy in pediatric patients.
- MeSH
- celková dávka radioterapie MeSH
- dítě MeSH
- dospělí MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- nádory epidemiologie radioterapie MeSH
- pediatrie metody statistika a číselné údaje MeSH
- předškolní dítě MeSH
- protonová terapie metody statistika a číselné údaje MeSH
- průzkumy a dotazníky MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Intramural MeSH
PURPOSE: For unbiased comparison of different radiation modalities and techniques, consensus on delineation of radiation sensitive organs at risk (OARs) and on their dose constraints is warranted. Following the publication of a digital, online atlas for OAR delineation in neuro-oncology by the same group, we assessed the brain OAR-dose constraints in a follow-up study. METHODS: We performed a comprehensive search to identify the current papers on OAR dose constraints for normofractionated photon and particle therapy in PubMed, Ovid Medline, Cochrane Library, Embase and Web of Science. Moreover, the included articles' reference lists were cross-checked for potential studies that met the inclusion criteria. Consensus was reached among 20 radiation oncology experts in the field of neuro-oncology. RESULTS: For the OARs published in the neuro-oncology literature, we summarized the available literature and recommended dose constraints associated with certain levels of normal tissue complication probability (NTCP) according to the recent ICRU recommendations. For those OARs with lacking or insufficient NTCP data, a proposal for effective and efficient data collection is given. CONCLUSION: The use of the European Particle Therapy Network-consensus OAR dose constraints summarized in this article is recommended for the model-based approach comparing photon and proton beam irradiation as well as for prospective clinical trials including novel radiation techniques and/or modalities.
- MeSH
- celková dávka radioterapie * MeSH
- konsensus MeSH
- kritické orgány * účinky záření MeSH
- lidé MeSH
- nádory mozku radioterapie MeSH
- plánování radioterapie pomocí počítače metody MeSH
- protonová terapie škodlivé účinky MeSH
- radioterapie těžkými ionty škodlivé účinky MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH