INTRODUCTION: An error grid compares measured versus reference glucose concentrations to assign clinical risk values to observed errors. Widely used error grids for blood glucose monitors (BGMs) have limited value because they do not also reflect clinical accuracy of continuous glucose monitors (CGMs). METHODS: Diabetes Technology Society (DTS) convened 89 international experts in glucose monitoring to (1) smooth the borders of the Surveillance Error Grid (SEG) zones and create a user-friendly tool-the DTS Error Grid; (2) define five risk zones of clinical point accuracy (A-E) to be identical for BGMs and CGMs; (3) determine a relationship between DTS Error Grid percent in Zone A and mean absolute relative difference (MARD) from analyzing 22 BGM and nine CGM accuracy studies; and (4) create trend risk categories (1-5) for CGM trend accuracy. RESULTS: The DTS Error Grid for point accuracy contains five risk zones (A-E) with straight-line borders that can be applied to both BGM and CGM accuracy data. In a data set combining point accuracy data from 18 BGMs, 2.6% of total data pairs equally moved from Zones A to B and vice versa (SEG compared with DTS Error Grid). For every 1% increase in percent data in Zone A, the MARD decreased by approximately 0.33%. We also created a DTS Trend Accuracy Matrix with five trend risk categories (1-5) for CGM-reported trend indicators compared with reference trends calculated from reference glucose. CONCLUSION: The DTS Error Grid combines contemporary clinician input regarding clinical point accuracy for BGMs and CGMs. The DTS Trend Accuracy Matrix assesses accuracy of CGM trend indicators.
- MeSH
- diabetes mellitus * krev diagnóza MeSH
- krevní glukóza * analýza MeSH
- lidé MeSH
- reprodukovatelnost výsledků MeSH
- selfmonitoring glykemie * přístrojové vybavení normy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Open-source automated insulin delivery systems, commonly referred to as do-it-yourself automated insulin delivery systems, are examples of user-driven innovations that were co-created and supported by an online community who were directly affected by diabetes. Their uptake continues to increase globally, with current estimates suggesting several thousand active users worldwide. Real-world user-driven evidence is growing and provides insights into safety and effectiveness of these systems. The aim of this consensus statement is two-fold. Firstly, it provides a review of the current evidence, description of the technologies, and discusses the ethics and legal considerations for these systems from an international perspective. Secondly, it provides a much-needed international health-care consensus supporting the implementation of open-source systems in clinical settings, with detailed clinical guidance. This consensus also provides important recommendations for key stakeholders that are involved in diabetes technologies, including developers, regulators, and industry, and provides medico-legal and ethical support for patient-driven, open-source innovations.
- MeSH
- diabetes mellitus 1. typu * farmakoterapie MeSH
- hypoglykemika terapeutické užití MeSH
- inzulin * terapeutické užití MeSH
- inzulinové infuzní systémy MeSH
- lidé MeSH
- zdravotnický personál MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Research Support, N.I.H., Extramural MeSH