Interventional electrophysiology offers a great variety of treatment options to patients suffering from symptomatic cardiac arrhythmia. Catheter ablation of supraventricular and ventricular tachycardia has globally evolved a cornerstone in modern arrhythmia management. Complex interventional electrophysiological procedures engaging multiple ablation tools have been developed over the past decades. Fluoroscopy enabled interventional electrophysiologist throughout the years to gain profound knowledge on intracardiac anatomy and catheter movement inside the cardiac cavities and hence develop specific ablation approaches. However, the application of X-ray technologies imposes serious health risks to patients and operators. To reduce the use of fluoroscopy during interventional electrophysiological procedures to the possibly lowest degree and to establish an optimal protection of patients and operators in cases of fluoroscopy is the main goal of modern radiation management. The present manuscript gives an overview of possible strategies of fluoroscopy reduction and specific radiation protection strategies.
- MeSH
- dávka záření MeSH
- elektrofyziologické techniky kardiologické MeSH
- fluoroskopie metody MeSH
- katetrizační ablace * MeSH
- lidé MeSH
- radiační expozice * škodlivé účinky MeSH
- srdeční arytmie terapie MeSH
- srdeční elektrofyziologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions' experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs.
- MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- komorová tachykardie * MeSH
- lidé MeSH
- prospektivní studie MeSH
- srdeční arytmie MeSH
- srdeční komory MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
AIMS: Atrial fibrillation (AF) recurrence during the first year after catheter ablation remains common. Patient-specific prediction of arrhythmic recurrence would improve patient selection, and, potentially, avoid futile interventions. Available prediction algorithms, however, achieve unsatisfactory performance. Aim of the present study was to derive from ESC-EHRA Atrial Fibrillation Ablation Long-Term Registry (AFA-LT) a machine-learning scoring system based on pre-procedural, easily accessible clinical variables to predict the probability of 1-year arrhythmic recurrence after catheter ablation. METHODS AND RESULTS: Patients were randomly split into a training (80%) and a testing cohort (20%). Four different supervised machine-learning models (decision tree, random forest, AdaBoost, and k-nearest neighbour) were developed on the training cohort and hyperparameters were tuned using 10-fold cross validation. The model with the best discriminative performance on the testing cohort (area under the curve-AUC) was selected and underwent further optimization, including re-calibration. A total of 3128 patients were included. The random forest model showed the best performance on the testing cohort; a 19-variable version achieved good discriminative performance [AUC 0.721, 95% confidence interval (CI) 0.680-0.764], outperforming existing scores (e.g. APPLE score: AUC 0.557, 95% CI 0.506-0.607). Platt scaling was used to calibrate the model. The final calibrated model was implemented in a web calculator, freely available at http://afarec.hpc4ai.unito.it/. CONCLUSION: AFA-Recur, a machine-learning-based probability score predicting 1-year risk of recurrent atrial arrhythmia after AF ablation, achieved good predictive performance, significantly better than currently available tools. The calculator, freely available online, allows patient-specific predictions, favouring tailored therapeutic approaches for the individual patient.
- MeSH
- fibrilace síní * diagnóza chirurgie MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- lidé MeSH
- recidiva MeSH
- registrace MeSH
- rizikové faktory MeSH
- strojové učení MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: The influence of risk factors on atrial fibrillation (AF) ablation recurrence is increasingly recognized. We present a sub-analysis of the European Society of Cardiology-European Heart Rhythm Association-European Society of Cardiology AF ablation long-term registry on the effect of traditional risk factors for AF on postablation recurrence, reablation, and complications using real-world data. METHODS: Risk factors for AF were defined as body mass index ≥27 kg/m², hypertension, chronic obstructive pulmonary disease, diabetes, alcohol ≥2 units/day, sleep apnea, smoking, no/occasional sports activity, moderate/severe mitral or aortic valve disease, any cardiomyopathy, peripheral vascular disease, chronic kidney disease, heart failure, coronary artery disease/infarction, and previous pacemaker/defibrillator implant. Patients were divided in two groups with ≥1 or without risk factors. Primary outcomes were arrhythmia recurrence after blanking period, reablation, and adverse events or death. Differences between the groups and the influence of individual risk factors were analyzed using multivariate Cox regression. RESULTS: Three thousand sixty nine patients were included; 217 patients were without risk factors. Risk factor patients were older (58.4 vs 54.1 years), more often female (32% vs 19.8%) and had more often persistent AF (27.2% vs 23.5%). In a multivariate analysis, patients without risk factors had a hazard ratio of 0.70 (95% CI 0.49-0.99) for recurrence compared to risk factor patients. The multivariate hazard ratios for reablation or adverse events/death were not different between the two groups. Hypertension and body mass index were univariate predictors of recurrence. CONCLUSIONS: Patients with ≥1 risk factor had a 30% higher risk for arrhythmia recurrence after ablation, but no differences in risk for repeat ablations and adverse events or death.
- MeSH
- fibrilace síní chirurgie MeSH
- katetrizační ablace metody MeSH
- komorbidita MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- recidiva MeSH
- registrace MeSH
- rizikové faktory MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND: Atrial fibrillation (AF) promotes atrial remodeling that in turn promotes AF perpetuation. The aim of our study is to investigate the impact of AF history length on 1-year outcome of AF catheter ablation in a cohort of patients enrolled in the Atrial Fibrillation Ablation Registry. METHODS: We described the real-life clinical epidemiology, therapeutic strategies, and the short- and mid-term outcomes of 1948 patients (71.9% with paroxysmal AF) undergoing AF ablation procedures, stratified according to AF history duration (<2 years or ≥2 years). RESULTS: The mean AF history duration was 46.2 ± 57.4 months, 592 patients had an AF history duration <2 years (mean 10.2 ± 5.9 months), and 1356 patients ≥2 years (mean 75.5 ± 63.5 months) (P < 0.001). Patients with AF history duration <2 years were younger; had a lower incidence of hypertension, coronary artery disease, and hypertrophic cardiomyopathy; and had a lower CHA2 DS2 -VaSc Score. At 1 year, the logrank test showed a lower incidence of AF recurrence in patients with AF history duration <2 years (28.9%) than in patients with AF history duration ≥2 years (34.0%) (P = 0.037). AF history duration ≥2 years, overall ablation procedure duration, hypertension, and chronic kidney disease were all predictors of recurrences after the blanking period. CONCLUSIONS: In this multicenter registry, performing catheter ablation in patients with an AF history ≥2 years was associated with higher rates of AF recurrences at 1 year. Since cumulative time in AF in not necessarily equivalent to AF history, its role remains to be clarified.
- MeSH
- fibrilace síní chirurgie MeSH
- katetrizační ablace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- recidiva MeSH
- registrace MeSH
- výsledky a postupy - zhodnocení (zdravotní péče) * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
BACKGROUND: Atrial fibrillation (AF) catheter ablation is increasingly proposed for patients suffering from AF and concomitant heart failure (HF). However, the optimal ablation strategy remains controversial. We performed this study to assess the prevalence of pulmonary vein (PV) or linear lesion reconnection in HF patients undergoing repeated procedures. METHODS AND RESULTS: At seven high-volume centres, 165 patients with HF underwent a repeat procedure after a first AF ablation including PV isolation alone (47 patients, group A) or PV isolation plus left atrial lines (118 patients, group B). Group A patients presented more often paroxysmal AF (p<0.001), less enlarged left atrium (p<0.001) and less left ventricular systolic dysfunction (p=0.031) compared to Group B, that more commonly had atypical atrial flutter (p<0.001). Forty-one (87%) patients in Group A and 69 (58%) in Group B presented at least one reconnected PV (p<0.001). Sixty-one (52%) patients in Group B presented at least one reconnected atrial line (left isthmus or roof). Patients without any reconnected PV (n=54, 33%) more frequently experienced persistent AF (p<0.001), had longer AF duration (p=0.047) and larger left atrial volume (p<0.001). Twenty-five patients (15%) with no PV and/or line reconnection did not significantly differ, concerning baseline characteristics, compared to those with at least one reconnected ablation site. CONCLUSION: As in the general AF population undergoing catheter ablation, PV reconnection is frequent in patients with HF and symptomatic recurrence. However, one third of patients presented arrhythmic recurrences even in the absence of PV reconnection, highlighting the importance of the underlying atrial substrate.
- MeSH
- dospělí MeSH
- fibrilace síní epidemiologie patofyziologie chirurgie MeSH
- katetrizační ablace trendy MeSH
- lidé středního věku MeSH
- lidé MeSH
- obnova funkce * fyziologie MeSH
- převodní systém srdeční fyziologie MeSH
- recidiva MeSH
- retrospektivní studie MeSH
- senioři MeSH
- srdeční selhání epidemiologie patofyziologie chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
AIMS: Diabetes mellitus (DM) and atrial fibrillation (AF) share pathophysiological links, as supported by the high prevalence of AF within DM patients. Catheter ablation of AF (AFCA) is an established therapeutic option for rhythm control in drug resistant symptomatic patients. Its efficacy and safety among patients with DM is based on small populations, and long-term outcome is unknown. The present systematic review and meta-analysis aims to assess safety and long-term outcome of AFCA in DM patients, focusing on predictors of recurrence. METHODS AND RESULTS: A systematic review was conducted in MEDLINE/PubMed and Cochrane Library. Randomized controlled trials, clinical trials, and observational studies including patients with DM undergoing AFCA were screened and included if matching inclusion and exclusion criteria. Fifteen studies were included, adding up to 1464 patients. Mean follow-up was 27 (20-33) months. Overall complication rate was 3.5 (1.5-5.0)%. Efficacy in maintaining sinus rhythm at follow-up end was 66 (58-73)%. Meta-regression analysis revealed that advanced age (P < 0.001), higher body mass index (P < 0.001), and higher basal glycated haemoglobin level (P < 0.001) related to higher incidence of arrhythmic recurrences. Performing AFCA lead to a reduction of patients requiring treatment with antiarrhythmic drugs (AADs) from 55 (46-74)% at baseline to 29 (17-41)% (P < 0.001) at follow-up end. CONCLUSIONS: Catheter ablation of AF safety and efficacy in DM patients is similar to general population, especially when performed in younger patients with satisfactory glycemic control. Catheter ablation of AF reduces the amount of patients requiring AADs, an additional benefit in this population commonly exposed to adverse effects of AF pharmacological treatments.
BACKGROUND: Catheter ablation of atrial fibrillation (AFCA) is an established therapeutic option for rhythm control in symptomatic patients. Its efficacy and safety among patients with left ventricular systolic dysfunction is based on small populations, and data concerning long-term outcome are limited. We performed this meta-analysis to assess safety and long-term outcome of AFCA in patients with left ventricular systolic dysfunction, to evaluate predictors of recurrence and impact on left ventricular function. METHODS AND RESULTS: A systematic review was conducted in MEDLINE/PubMed and Cochrane Library. Randomized controlled trials, clinical trials, and observational studies including patients with left ventricular systolic dysfunction undergoing AFCA were included. Twenty-six studies were selected, including 1838 patients. Mean follow-up was 23 (95% confidence interval, 18-40) months. Overall complication rate was 4.2% (3.6%-4.8%). Efficacy in maintaining sinus rhythm at follow-up end was 60% (54%-67%). Meta-regression analysis revealed that time since first atrial fibrillation (P=0.030) and heart failure (P=0.045) diagnosis related to higher, whereas absence of known structural heart disease (P=0.003) to lower incidence of atrial fibrillation recurrences. Left ventricular ejection fraction improved significantly during follow-up by 13% (P<0.001), with a significant reduction of patients presenting an ejection fraction <35% (P<0.001). N-terminal pro-brain natriuretic peptide blood levels decreased by 620 pg/mL (P<0.001). CONCLUSIONS: AFCA efficacy in patients with impaired left ventricular systolic function improves when performed early in the natural history of atrial fibrillation and heart failure. AFCA provides long-term benefits on left ventricular function, significantly reducing the number of patients with severely impaired systolic function.
- MeSH
- biologické markery krev MeSH
- časové faktory MeSH
- dysfunkce levé srdeční komory komplikace diagnóza patofyziologie MeSH
- fibrilace síní komplikace diagnóza patofyziologie chirurgie MeSH
- funkce levé komory srdeční * MeSH
- katetrizační ablace * škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- natriuretický peptid typu B krev MeSH
- obnova funkce MeSH
- odds ratio MeSH
- peptidové fragmenty krev MeSH
- recidiva MeSH
- rizikové faktory MeSH
- rozdělení chí kvadrát MeSH
- systola * MeSH
- tepový objem MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- přehledy MeSH