We report the forensic case of a 42-year-old man, a known drug user, who died at home and whose body was only discovered 2 months later. Autopsy was performed on a corpse in the late postmortem stage where no apparent cause of death was found. A toxicological screening of biological materials (blood, urine and gastric content) using liquid chromatography with different types of mass detection (ion trap and high-resolution) revealed the presence of methoxetamine (MXE), a ketamine analog, and its metabolites. MXE and a number of its metabolites (e.g., O-desmethyl, N-desethyl, hydroxy, glucuronides and sulfates) were identified in urine. Based on the results, a method using liquid chromatography with tandem mass spectrometry was developed and validated for the determination of MXE concentration in biological materials. The following values of MXE concentration were found: blood-3.6 ng/mL, urine-70.5 ng/mL and gastric content-18.0 ng/mL. Given the absence of other drugs, medications and poisons, it can be inferred that despite relatively low blood concentrations, MXE contributed to the victim's death. The present case demonstrates that even after 2 months, MXE and its several metabolites can be detected and determined in the human cadaver at a relatively advanced stage of decomposition.
- MeSH
- cyklohexanony * analýza metabolismus MeSH
- cyklohexylaminy * MeSH
- dospělí MeSH
- lidé MeSH
- mrtvola MeSH
- pitva MeSH
- tělesné tekutiny * metabolismus MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
Riociguat is novel antihypertensive drug for treatment of pulmonary hypertension. As such, it is still being tested in many clinical and pharmacokinetic trials. Existing methods that determine serum riociguat and desmethylriociguat (DMR) are based solely on liquid chromatography with mass spectrometry. Therefore, we present a novel capillary electrophoresis with mass spectrometry method (CE-MS) for their determination in human serum as alternative method for ongoing trials. Complete resolution of both analytes was achieved by means of pH optimization of ammonium formate background electrolytes that are fully compatible with ESI/MS detection. Simple liquid-liquid extraction was used as sample pretreatment. The calibration dependence of the method was linear (in the range of 10-1000 ng/mL), with adequate accuracy (90.1-114.9%) and precision (13.4%). LOD and LOQ were arbitrarily set at 10 ng/mL for both analytes. Clinical applicability was validated using serum samples from patients treated with riociguat in pharmacokinetic study and the results corresponded with reference HPLC-MS/MS values. Capillary electrophoresis proved to be sensitive and selective tool for the analysis of riociguat and DMR.
- MeSH
- elektroforéza kapilární metody MeSH
- elektrolyty MeSH
- extrakce kapalina-kapalina MeSH
- hmotnostní spektrometrie s elektrosprejovou ionizací metody MeSH
- lidé MeSH
- limita detekce MeSH
- lineární modely MeSH
- pyrazoly krev chemie izolace a purifikace farmakokinetika MeSH
- pyrimidiny krev chemie izolace a purifikace farmakokinetika MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Pharmacokinetic data for riociguat in patients with chronic thromboembolic pulmonary hypertension (CTEPH) have previously been reported from randomized clinical trials, which may not fully reflect the population encountered in routine practice. The aim of the current study was to characterize the pharmacokinetic of riociguat and its metabolite M1 in the patients from routine clinical practice. A population pharmacokinetic model was developed in NONMEM 7.3, based on riociguat and its metabolite plasma concentrations from 49 patients with CTEPH. One sample with riociguat and M1 concentrations was available from each patient obtained at different time points after last dose. Age, bodyweight, sex, smoking status, concomitant medications, kidney and liver function markers were tested as potential covariates of pharmacokinetic of riociguat and its metabolite. Riociguat and M1 disposition was best described with one-compartment models. Apparent volume of distribution (Vd/F) for riociguat and M1 were assumed to be the same. Total bilirubin and creatinine clearance were the most predictive covariates for apparent riociguat metabolic clearance to M1 (CLf,M1/F) and for apparent riociguat clearance through remaining pathways (CLe,r/F), respectively. CLf,M1/F, CLe,r/F, Vd/F of riociguat and M1, and clearance of M1 (CLe,M1/F) for a typical individual with 70 mL/min creatinine clearance and 0.69 mg/dL total bilirubin were 0.665 L/h (relative standard error = 17%)), 0.66 (18%) L/h, 3.63 (15%) L and 1.47 (19%) L/h, respectively. Upon visual identification of six outlying individuals, an absorption lag-time of 2.95 (6%) h was estimated for these patients. In conclusion, the only clinical characteristics related to riociguat exposure in patients with CTEPH from routine clinical practice are total bilirubin and creatinine clearance. This confirms the findings of the previous population pharmacokinetic studies based on data from randomized clinical trials.
- Publikační typ
- časopisecké články MeSH
Riociguat is a novel antihypertensive drug for the treatment of pulmonary hypertension. We present electrophoretic characterization, i.e. migration behavior of riociguat and metabolite M1 as support for optimized CZE/MS assay. Fundamental separation parameters, such as peak width, symmetry, and resolution are studied in a series of ammonium formate buffers within pH range 2.60-5.61. The narrow region of peak symmetry lies close to pH 4.0 for both analytes. Accordingly, the value of resolution maximizes in a background electrolyte adjusted to pH 4.10. Basic calibration parameters estimated from CZE experiments with absorption photometric and mass spectrometric detection of riociguat and metabolite M1 were evaluated. More than three orders lower LOD was achieved with high resolution mass spectrometric detection. The observed difference in the sensitivity of both detection techniques gives priority to the utilization of CZE/MS in practice. The values of dissociation constants of riociguat and metabolite M1, pKBH , were determined from CZE measurements in lithium formate and lithium acetate background electrolytes with constant ionic strength. The value of pKBH = 4.30 ± 0.02 for riociguat corresponds well to the value already presented in the literature. According to our observation, metabolite M1 behaves like a slightly stronger base with estimated pKBH = 4.40 ± 0.02.
- MeSH
- elektroforéza kapilární metody MeSH
- hmotnostní spektrometrie metody MeSH
- lidé MeSH
- limita detekce MeSH
- lineární modely MeSH
- pyrazoly analýza krev chemie metabolismus MeSH
- pyrimidiny analýza krev chemie metabolismus MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
In the last decade there has been a dramatic increase in the availability and abuse of synthetic cathinones - new amphetamine-like stimulants. Even though their abuse during pregnancy could have serious adverse effects on the fetus, cathinones are not readily included in neonatal toxicological screenings. Meconium (first neonatal stool) is the specimen of choice to reveal long term drug exposure, however as it is a highly complex matrix, the sample preparation is a critical step before the instrumental analysis. The aim of this work was to develop a suitable meconium sample extraction technique using the advantages of salting-out assisted liquid-liquid extraction (SALLE) and using only MS-friendly organic ammonium salts. We further developed and validated liquid chromatography tandem-mass spectrometry method for the determination of 'traditional' stimulants (methamphetamine, amphetamine, MDMA) and cathinones (mephedrone, methylenedioxypyrovalerone (MDPV), α-pyrrolidinopentiophenone (α-PVP), methylone, butylone, flephedrone, and naphyrone). Matrix-matched calibration was prepared in the concentration range 10-2000 ng/g. The limits of quantification were determined as 10 ng/g, recoveries ranged from 48.2% to 94.3% and the matrix effect was between 60.2% and 101.4%. Accuracy (86.1-114.5%) and precision (4.9-14.9%) were determined and all validation criteria were met for all analytes except for naphyrone. Finally, our analytical method was tested on a set of real meconium samples, which were found positive for amphetamine, methamphetamine and methylone, thus demonstrating the validity of the method.
- MeSH
- amfetaminy analýza MeSH
- amoniové sloučeniny chemie MeSH
- extrakce kapalina-kapalina metody MeSH
- komplikace těhotenství diagnóza MeSH
- lidé MeSH
- limita detekce MeSH
- mekonium chemie MeSH
- novorozenec MeSH
- odhalování abúzu drog metody MeSH
- poruchy spojené s užíváním psychoaktivních látek diagnóza MeSH
- stimulanty centrálního nervového systému analýza MeSH
- studie proveditelnosti MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- těhotenství MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Check Tag
- lidé MeSH
- novorozenec MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
A new time-integrated thermal desorption technique has been developed that can be used with selected ion flow tube mass spectrometry, TI-TD/SIFT-MS, for off-line quantitative analyses of VOCs accumulated onto sorbents. Using a slow desorption temperature ramp, the absolute amounts of desorbed compounds can be quantified in real time by SIFT-MS and constitutional isomers can be separated. To facilitate application of this technique to environmental atmospheric monitoring, method parameters were optimised for quantification of the three common atmospheric monoterpenes: β-pinene, R-limonene and 3-carene. Three sorbent types, Tenax TA, Tenax GR and Porapak Q, were tested under 26 different desorption conditions determined by the "design of experiment", DOE, systematic approach. The optimal combination of type of sorbent, bed length, sampling flow rate, sample volume and the initial desorption temperature was determined from the experimental results by ANOVA. It was found that Porapak Q exhibited better efficiency of sample collection and further extraction for total monoterpene concentration measurements. On the other hand, Tenax GR or TA enabled separation of all three monoterpenes. The results of this laboratory study were tested with the sample accumulated from a branch of a Pinus nigra tree. Graphical abstract.
- Publikační typ
- časopisecké články MeSH
Perampanel is a novel antiepileptic drug used in paediatric patients. Existing methods that determine serum perampanel are of limited practicability. We developed a novel capillary electrophoresis (CE) method using a new version of acetonitrile stacking for on-line sample pre-concentration, and fluorescence detection (FD). CE separations were performed in a fused-silica capillary where the electroosmotic flow was reduced by coating the inner surface using a INST coating solution. The optimised background electrolyte composition was 50 mM chloroacetic acid with addition of 0.5% m/v polyvinylalcohol (pH 2.15) and separation was driven by application of positive voltage + 30 kV. Serum samples (25 μL) treated by the addition of acetonitrile in a ratio of 1:3 v/v were each injected into the capillary at a large volume that corresponded to the length (129 mm) of the sample zone (hydrodynamic pressure impulse 6000 mbars). Acetonitrile stacking is based on the forcing the sample zone out of the capillary with simultaneous application of the separation voltage. Under such conditions, the enhancing factor achieves the value 57 for peak area compared to the small sample injection length (3.2 mm, hydrodynamic pressure impulse 150 mbar.s). A fluorescence detector with a broad excitation filter (240-400 nm) and an emission filter (495 nm) was used for visualisation of the native fluorescence of perampanel. The calibration dependence of the method was linear (in the range of 10-1000 ng mL-1), with adequate accuracy (99.8-103.3 %) and precision (13.1%). LOD and LOQ for perampanel were 2.9 ng mL-1 and 9.5 ng mL-1, respectively. Clinical applicability was validated using serum samples from patients treated with perampanel and the results corresponded with reference LC-MS/MS values. Our method offers a promising alternative for determining serum perampanel with several advantages. In particular, the low quantity of serum (25 μL) required means that testing can be performed on samples obtained for monitoring other antiepileptic medications, and thus reduces the test-burden on paediatric patients.
- MeSH
- acetonitrily chemie MeSH
- antikonvulziva MeSH
- elektroforéza kapilární metody MeSH
- fluorescence MeSH
- kalibrace MeSH
- lidé MeSH
- limita detekce MeSH
- monitorování léčiv metody MeSH
- pyridony krev MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- validační studie MeSH
High anion gap metabolic acidosis frequently complicates acute paracetamol overdose and is generally attributed to lactic acidosis or compromised hepatic function. However, metabolic acidosis can also be caused by organic acid 5-oxoproline (pyroglutamic acid). Paracetamol's toxic intermediate, N-acetyl-p-benzoquinoneimine irreversibly binds to glutathione and its depletion leads to subsequent disruption of the gamma glutamyl cycle and an excessive 5-oxoproline generation. This is undoubtedly an underdiagnosed condition because measurement of serum 5-oxoproline level is not readily available. A simple, cost effective, and fast capillary electrophoresis method with diode array detection (DAD) for simultaneous measurement of both paracetamol (acetaminophen) and 5-oxoproline in serum was developed and validated. This method is highly suitable for clinical toxicology laboratory diagnostic, allowing rapid quantification of acidosis inducing organic acid 5-oxoproline present in cases of paracetamol overdose. The calibration dependence of the method was proved to be linear in the range of 1.3-250μgmL-1, with adequate accuracy (96.4-107.8%) and precision (12.3%). LOQ equaled 1.3μgmL-1for paracetamol and 4.9μgmL-1for 5-oxoproline.
- MeSH
- acidóza MeSH
- elektroforéza kapilární * MeSH
- kyselina pyrrolidonkarboxylová MeSH
- lidé MeSH
- neopioidní analgetika MeSH
- paracetamol MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
The true bugs (Hemiptera: Heteroptera) have evolved a system of well-developed scent glands that produce diverse and frequently strongly odorous compounds that act mainly as chemical protection against predators. A new method of non-lethal sampling with subsequent separation using gas chromatography with mass spectrometric detection was proposed for analysis of these volatile defensive secretions. Separation was performed on Rtx-200 column containing fluorinated polysiloxane stationary phase. Various mechanical irritation methods (ultrasonics, shaking, pressing bugs with plunger of syringe) were tested for secretion sampling with a special focus on non-lethal irritation. The preconcentration step was performed by sorption on solid phase microextraction (SPME) fibers with different polarity. For optimization of sampling procedure, Pyrrhocoris apterus was selected. The entire multi-parameter optimization procedure of secretion sampling was performed using response surface methodology. The irritation of bugs by pressing them with a plunger of syringe was shown to be the most suitable. The developed method was applied to analysis of secretions produced by adult males and females of Pyrrhocoris apterus, Pyrrhocoris tibialis and Scantius aegyptius (all Heteroptera: Pyrrhocoridae). The chemical composition of secretion, particularly that of alcohols, aldehydes and esters, is species-specific in all three pyrrhocorid species studied. The sexual dimorphism in occurrence of particular compounds is largely limited to alcohols and suggests their epigamic intraspecific function. The phenetic overall similarities in composition of secretion do not reflect either relationship of species or similarities in antipredatory color pattern. The similarities of secretions may be linked with antipredatory strategies. The proposed method requires only a few individuals which remain alive after the procedure. Thus secretions of a number of species including even the rare ones can be analyzed and broadly conceived comparative studies can be carried out.
A simple, sensitive and robust method for simultaneous determination of antiepileptic drugs (gabapentin, pregabalin and vigabatrin) in human serum using GC-MS was developed and validated for clinical toxicology purposes. This method employs an emerging class of derivatization agents - alkyl chloroformates allowing the efficient and rapid derivatization of both the amino and carboxylic groups of the tested antiepileptic drugs within seconds. The derivatization protocol was optimized using the Design of Experiment statistical methodology, and the entire sample preparation requires less than 5 min. Linear calibration curves were obtained in the concentration range from 0.5 to 50.0 mg/L, with adequate accuracy (97.9-109.3%) and precision (<12.1%). The method was successfully applied to quantification of selected γ-aminobutyric acid analogs in the serum of patients in both therapeutic and toxic concentration ranges.
- MeSH
- aminy analýza krev MeSH
- antikonvulziva analýza krev MeSH
- design s pomocí počítače MeSH
- formiáty chemie MeSH
- GABA analogy a deriváty analýza krev MeSH
- kalibrace MeSH
- kyseliny cyklohexankarboxylové analýza krev MeSH
- lidé MeSH
- plynová chromatografie s hmotnostně spektrometrickou detekcí MeSH
- pregabalin analýza krev MeSH
- vigabatrin analýza krev MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH