Czech physiologist Penaz tried to overcome limitations of invasive pulse-contour methods (PCM) in clinical applications by a non-invasive method (finger mounted BP cuff) for continuous arterial waveform detection and beat-to-beat analysis. This discovery resulted in significant interest in human physiology and non-invasive examination of hemodynamic parameters, however has limitations because of the distal BP recording using a volume-clamp method. Thus, we propose a validation of beat-to-beat signal analysis acquired by novel a brachial occlusion-cuff (suprasystolic) principle and signal obtained from Finapres during a forced expiratory effort against an obstructed airway (Valsalva maneuver). Twelve healthy adult subjects [2 females, age = (27.2 ± 5.1) years] were in the upright siting position, breathe through the mouthpiece (simultaneously acquisition by brachial blood pressure monitor and Finapres) and at a defined time were asked to generate positive mouth pressure for 20 s (Valsalva). For the purpose of signal analysis, we proposed parameter a "Occlusion Cuff Index" (OCCI). The assumption about similarities between measured signals (suprasystolic brachial pulse waves amplitudes and Finapres's MAP) were proved by averaged Pearson's correlation coefficient (r- = 0.60, p < 0.001). The averaged Pearson's correlation coefficient for the comparative analysis of OCCI between methods was r- = 0.88, p < 0.001. The average percent change of OCCI during maneuver: 8% increase, 19% decrease and percent change of max/min ratio is 35%. The investigation of brachial pulse waves measured by novel brachial blood pressure monitor shows positive correlation with Finapres and the parameter OCCI shows promise as an index, which could describe changes during beat-to-beat cardiac cycles.
- MeSH
- analýza pulzové vlny * MeSH
- arteria brachialis * fyziologie MeSH
- dospělí MeSH
- krevní tlak fyziologie MeSH
- lidé MeSH
- měření krevního tlaku metody MeSH
- mladý dospělý MeSH
- prsty ruky MeSH
- srdeční frekvence MeSH
- studie proveditelnosti MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the 'cuff pulsatility index'. PURPOSE: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. METHODS: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m-2) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient's dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). RESULTS: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. CONCLUSIONS: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.
- MeSH
- arterie patofyziologie MeSH
- asistovaná cirkulace přístrojové vybavení metody MeSH
- diagnostické techniky kardiovaskulární MeSH
- krevní tlak fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- podpůrné srdeční systémy * MeSH
- pulz metody MeSH
- pulzatilní průtok fyziologie MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- srdeční selhání * patofyziologie terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Exercise oscillatory ventilation (EOV) is a consequence of ventilatory control system instability and is commonly observed in patients with advanced heart failure (HF); it is associated with adverse prognosis. The goal of this study was to evaluate the effects of cardiac resynchronization therapy (CRT) on oscillatory ventilation as quantified by a proposed EOV score. METHODS AND RESULTS: Consecutive patients with HF (N = 35) who underwent clinically indicated CRT, cardiopulmonary exercise testing and carbon dioxide (CO2) chemosensitivity by rebreathe before and 4-6 months after CRT were included in this post hoc analysis. With CRT, EOV scores improved in 22 patients (63%). In these patients, left ventricular ejection fraction, left atrial volume, brain natriuretic peptide concentration, and CO2 chemosensitivity significantly improved after CRT (P < 0.05). Furthermore, minute ventilation per unit CO2 production significantly decreased, and end-tidal CO2 increased at rest and at peak exercise post-CRT. Multiple regression analysis showed only the change of CO2 chemosensitivity to be significantly associated with the improvement of the EOV score (b = 0.64; F = 11.3; P = 0.004). In the group without EOV score improvement (n = 13), though left ventricular ejection fraction significantly increased with CRT (P = 0.015), no significant changes in ventilation or gas exchange were observed. CONCLUSION: The EOV score was mitigated by CRT and was associated with decreased CO2 chemosensitivity.
- MeSH
- funkce levé komory srdeční MeSH
- lidé MeSH
- srdeční resynchronizační terapie * MeSH
- srdeční selhání * terapie MeSH
- tepový objem MeSH
- zátěžový test MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
The heart and lungs are intimately linked. Hence, impaired function of one organ may lead to changes in the other. Accordingly, heart failure is associated with airway obstruction, loss of lung volume, impaired gas exchange, and abnormal ventilatory control. Cardiopulmonary exercise testing is an excellent tool for evaluation of gas exchange and ventilatory control. Indeed, many parameters routinely measured during cardiopulmonary exercise testing, including the level of minute ventilation per unit of carbon dioxide production and the presence of exercise oscillatory ventilation, have been found to be strongly associated with prognosis in patients with heart failure.
- MeSH
- lidé MeSH
- plíce patofyziologie MeSH
- srdeční selhání patofyziologie MeSH
- výměna plynů v plicích fyziologie MeSH
- zátěžový test metody MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Research Support, N.I.H., Extramural MeSH
The gold standard for noninvasive blood pressure (BP) measurement, the Doppler technique, does not provide systolic blood pressure (SBP) and diastolic blood pressure (DBP) and may limit therapy outcomes. To improve patient care, we tested specifically designed experimental BP (ExpBP) monitor and the Doppler technique by comparing noninvasive measures to the intraarterial (I-A) BP in 31 patients with end-stage heart failure (4 females) 2.6 ± 3.4 days post-LVAD implantation (20 HeartMate II and 11 HeartWare). Bland-Altman plots revealed that the ExpBP monitor overestimated mean arterial pressure (MAP) by 1.2 (4.8) mm Hg (mean difference [standard deviation]), whereas the Doppler by 6.7 (5.8) mm Hg. The ExpBP SBP was overestimated by 0.8 (6.1) mm Hg and DBP by 1.9 (5.3) mm Hg compared with the respective I-A pressures. Both techniques achieved similar measurement reliability. In the measurement "success rate" expressed as a frequency (percent) of readable BP values per measurement attempts, Doppler accomplished 100% vs. 97%, 97%, and 94% of successful detections of MAP, SBP, and DBP provided by the ExpBP monitor. The ExpBP monitor demonstrated higher accuracy in the MAP assessment than the Doppler in addition to providing SBP and DBP in majority of subjects. Improved BP control may help to mitigate related neurologic adverse event rates.
- MeSH
- arteriální tlak fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- měření krevního tlaku přístrojové vybavení MeSH
- monitory krevního tlaku * MeSH
- podpůrné srdeční systémy * MeSH
- reprodukovatelnost výsledků MeSH
- srdeční selhání patofyziologie terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
INTRODUCTION: Measurement of ventilatory efficiency, defined as minute ventilation per unit carbon dioxide production (VE/VCO2), by cardiopulmonary exercise testing (CPET) has been proposed as a screen for hyperventilation syndrome (HVS). However, increased VE/VCO2 may be associated with other disorders which need to be distinguished from HVS. A more specific marker of HVS by CPET would be clinically useful. We hypothesized ventilatory control during exercise is abnormal in patients with HVS. METHODS: Patients who underwent CPET from years 2015 through 2017 were retrospectively identified and formed the study group. HVS was defined as dyspnea with respiratory alkalosis (pH >7.45) at peak exercise with absence of acute or chronic respiratory, heart or psychiatric disease. Healthy patients were selected as controls. For comparison the Student t-test or Mann-Whitney U test were used. Data are summarized as mean ± SD or median (IQR); p<0.05 was considered significant. RESULTS: Twenty-nine patients with HVS were identified and 29 control subjects were selected. At rest, end-tidal carbon dioxide (PETCO2) was 27 mmHg (25-30) for HVS patients vs. 30 mmHg (28-32); in controls (p = 0.05). At peak exercise PETCO2 was also significantly lower (27 ± 4 mmHg vs. 35 ± 4 mmHg; p<0.01) and VE/VCO2 higher ((38 (35-43) vs. 31 (27-34); p<0.01)) in patients with HVS. In contrast to controls, there were minimal changes of PETCO2 (0.50 ± 5.26 mmHg vs. 6.2 ± 4.6 mmHg; p<0.01) and VE/VCO2 ((0.17 (-4.24-6.02) vs. -6.6 (-11.4-(-2.8)); p<0.01)) during exercise in patients with HVS. The absence of VE/VCO2 and PETCO2 change during exercise was specific for HVS (83% and 93%, respectively). CONCLUSION: Absence of VE/VCO2 and PETCO2 change during exercise may identify patients with HVS.
- MeSH
- dospělí MeSH
- dyspnoe patofyziologie MeSH
- hyperventilace diagnóza patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- oxid uhličitý metabolismus MeSH
- spotřeba kyslíku fyziologie MeSH
- srdeční selhání patofyziologie MeSH
- tolerance zátěže MeSH
- zátěžový test * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
Low leptin concentration has been shown to be associated with central sleep apnea in heart failure patients. We hypothesized that low leptin concentration predicts central sleep apnea. Consecutive ambulatory New York Heart Association (NYHA) classes I-IV heart failure patients were studied prospectively, including measurement of serum leptin, echocardiography and polysomnography. Sleep apnea was defined by type (central/mixed/obstructive) and by apnea-hypopnea index ≥5 by polysomnography. Subjects were divided into four groups by polysomnography: (1) central sleep apnea, (2) mixed apnea, (3) no apnea and (4) obstructive sleep apnea. Fifty-six subjects were included. Eighteen subjects were diagnosed with central sleep apnea, 15 with mixed apnea, 12 with obstructive apnea and 11 with no sleep apnea. Leptin concentration was significantly lower in central sleep apnea compared to obstructive apnea (8 ± 10.7 ng mL-1 versus 19.7 ± 14.7 ng mL-1 , P ˂ 0.01) or no sleep apnea (8 ± 10.7 ng mL-1 versus 17.1 ± 8.4 ng mL-1 , P ˂ 0.01). Logistic regression showed leptin to be associated independently with central sleep apnea [odds ratio (OR): 0.19; 95% confidence interval (CI): 0.06-0.62; area under the curve (AUC): 0.80, P < 0.01]. For the detection of central sleep apnea, a cut-off value for leptin concentration 5 ng mL-1 yielded a sensitivity of 50% and specificity of 89%. In conclusion, a low leptin concentration may have utility for the screening of heart failure patients for central sleep apnea.
- MeSH
- biologické markery krev MeSH
- leptin krev MeSH
- lidé středního věku MeSH
- lidé MeSH
- polysomnografie metody MeSH
- prospektivní studie MeSH
- senioři MeSH
- spánková apnoe centrální krev diagnostické zobrazování epidemiologie MeSH
- srdeční selhání krev diagnostické zobrazování epidemiologie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
BACKGROUND: Leptin modulates ventilation and circulating levels are higher in normal women than men. OBJECTIVES: The aim of this study was to compare exercise ventilation and gas exchange in men and women with heart failure (HF) and their relation to circulating leptin concentration. METHODS: Consecutive HF patients were studied by cardiopulmonary exercise testing and assay of circulating leptin concentration. RESULTS: Fifty-seven men and 20 women were similar with respect to age, BMI, NYHA class, left ventricular ejection fraction, and peak oxygen consumption (all p > 0.05). Leptin concentration was lower (10.3 ± 10 vs. 25.3 ± 16 ng/mL; p < 0.01) and peak exercise ventilatory efficiency (VE/VCO2) was higher (43 ± 10 vs. 36 ± 5; p < 0.01) in men. Leptin concentration was associated with peak exercise VE/VCO2 (b = -0.35; F = 5.6; p = 0.02). CONCLUSION: Men have significantly lower circulating leptin concentration and increased ventilatory drive during exercise than women with comparable HF. In men with HF, lower leptin concentration may account for an increased ventilatory drive.
- MeSH
- biologické markery krev MeSH
- cvičení fyziologie MeSH
- funkce levé komory srdeční fyziologie MeSH
- leptin krev MeSH
- lidé středního věku MeSH
- lidé MeSH
- plicní ventilace fyziologie MeSH
- prospektivní studie MeSH
- senioři MeSH
- sexuální faktory MeSH
- spotřeba kyslíku MeSH
- srdeční selhání krev patofyziologie MeSH
- zátěžový test metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
Cardiac output (CO) assessment as a basic hemodynamic parameter has been of interest in exercise physiology, cardiology, and anesthesiology. Noninvasive techniques available are technically challenging, and thus difficult to use outside of a clinical or laboratory setting. We propose a novel method of noninvasive CO assessment using a single, upper-arm cuff. The method uses the arterial pressure pulse wave signal acquired from the brachial artery during 20-s intervals of suprasystolic occlusion. This method was evaluated in a cohort of 12 healthy individuals (age, 27.7 ± 5.4 yr, 50% men) and compared with an established method for noninvasive CO assessment, the open-circuit acetylene method (OpCirc) at rest, and during low- to moderate-intensity exercise. CO increased from rest to exercise (rest, 7.4 ± 0.8 vs. 7.2 ± 0.8; low, 9.8 ± 1.8 vs. 9.9 ± 2.0; moderate, 14.1 ± 2.8 vs. 14.8 ± 3.2 l/min) as assessed by the cuff-occlusion and OpCirc techniques, respectively. The average error of experimental technique compared with OpCirc was -0.25 ± 1.02 l/min, Pearson's correlation coefficient of 0.96 (rest + exercise), and 0.21 ± 0.42 l/min with Pearson's correlation coefficient of 0.87 (rest only). Bland-Altman analysis demonstrated good agreement between methods (within 95% boundaries); the reproducibility coefficient (RPC) = 0.84 l/min with R2 = 0.75 at rest and RPC = 2 l/min with R2 = 0.92 at rest and during exercise, respectively. In comparison with an established method to quantify CO, the cuff-occlusion method provides similar measures at rest and with light to moderate exercise. Thus, we believe this method has the potential to be used as a new, noninvasive method for assessing CO during exercise.
- MeSH
- acetylen farmakologie MeSH
- arteria brachialis účinky léků fyziologie MeSH
- cvičení fyziologie MeSH
- dospělí MeSH
- krevní tlak účinky léků fyziologie MeSH
- lidé MeSH
- minutový srdeční výdej účinky léků fyziologie MeSH
- odpočinek fyziologie MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Heart failure (HF) is characterized by heightened sensitivities of the CO2 chemoreflex and the ergoreflex which promote increased ventilatory drive manifested as increased minute ventilation per volume of expired CO2 (VE/VCO2). The aims of this study were to evaluate the effects of cardiac resynchronization therapy (CRT) on carbon dioxide (CO2) chemosensitivity and the arterial CO2 setpoint. METHODS AND RESULTS: Consecutive HF patients (n = 35) who underwent clinically indicated CRT were investigated by means of cardiopulmonary exercise testing and CO2 chemosensitivity evaluation with the use of a rebreathe method before and 4-6 months after CRT. Pre- and post-CRT measures were compared with the use of either paired t test or Wilcoxon test. Decreased peak VE/VCO2 (44 ± 10 vs 40 ± 8; P < .01), CO2 chemosensitivity (2.2 ± 1.1 vs 1.7 ± 0.8 L min(-1) mm Hg(-1); P = .04), and increased peak end-tidal CO2 (29 ± 5 vs 31 ± 5 mm Hg; P < .01) were also observed after CRT. Multivariate analysis adjusted for age and sex showed the decrease of peak VE/VCO2 from before to after CRT to be most strongly associated with the increase of peak end-tidal CO2 (β = -0.84; F = 21.5; P < .0001). CONCLUSIONS: Decrease of VE/VCO2 after CRT is associated with decreased CO2 chemosensitivity and increase of the arterial CO2 setpoint, which is consistent with decreased activation of both the CO2 chemoreflex and the ergoreflex.
- MeSH
- analýza krevních plynů metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- oxid uhličitý metabolismus MeSH
- plicní ventilace fyziologie MeSH
- senioři MeSH
- spotřeba kyslíku fyziologie MeSH
- srdeční resynchronizační terapie metody MeSH
- srdeční selhání diagnóza metabolismus terapie MeSH
- zátěžový test metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH